MM
-
product
2.92 mm to 2.92 mm Test Cable
C50292MM
Our 2.92 mm test cable is made to ideally suit our larger line of vector network analyzers. The C50292MM test cable operates at a frequency of 40000 MHz and is compatible with our PC-driven vector network analyzers.
-
product
Flexible Cable Set, 3.5 Mm (Test Port) To 7 Mm
85132F
The Keysight 85132F is a 62.9 cm (24.75 in) long¹ flexible cable set composed of two 3.5 mm female² to 7 mm connectors. Cable frequency range is dc to 18 GHz with a return loss greater than or equal to 17 dB. Insertion loss is 0.25 * sqrt(f) + 0.2, where f is frequency in GHz, for the test port connector and device connector. Phase stability of semi-rigid/flexible cables is specified with a 90 degree bend using a 4 to 3 inch radius. Stability¹ of the Keysight 85132F is less than 0.12 dB and phase is 0.13 * f + 0.5, where f is frequency in GHz.
-
product
Adapter, 1.0 Mm (f) To 1.0 Mm (f), DC To 120 GHz
Y1910B
Y1910B Adapter, 1.0 mm (f) to 1.0 mm (f), DC to 120 GHz provides measurement accuracy, versatility, and ease of use for on-wafer and coaxial measurements.
-
product
Attenuator Interconnect Kit, 2.4 mm
11716F
The 11716F attenuator interconnection kit provides the necessary parts to connect 84904/8M and 84904/6L programmable step attenuators in series.
-
product
Calibrator, 0 to 24 mA, Current, 185 mm, 78 mm, 38 mm, ± 0.5%, 265 g
72-6694
*Adjustable 0 to 24 mA current source*Current calibrator drives loads up to 500 Ω*Large LCD display*Sampling Time : Approximately 0.4 seconds*Over Input Indicator : 1*Operating Temperature : 0°C to 50°C ( 32°F to 122°F)*Size : 185 × 78 × 38 mm (7.3 × 3 × 1.5 inches)*Weight : 265 g (0.58 lb) including battery*Requires one 9 V battery - not included*12 month limited warranty *view Terms & Conditions for details
-
product
Test Port Cable, 1 Mm
11500L
Connect test ports to devices, fixtures, or probe tips with this 24-cm cable featuring a return loss of 16 dB minimum.
-
product
Flexible Cable, 2.4 Mm To 3.5 Mm
85134H
The Keysight 85134H is a 62.9 cm (24.75 in) long1 flexible cable with a 2.4 mm female2 to 3.5 mm male connector. Cable frequency range is dc to 26.5 GHz with a return loss greater than or equal to 16 dB. Insertion loss is 0.31 * sqrt (f) + 0.2 (where f is frequency is GHz) for the test port connector and 1.8 dB at maximum frequency for the device connector. Phase stability of semi-rigid/flexible cables is characterized with a 90 degree bend using a 2.5 inch radius. Stability1 of the Keysight 85134H is less than 0.12 dB and phase is less than 0.13o * f + 0.5o, (where f is frequency in GHz).
-
product
Calibrator, Calibrated w/Data, Current, 185 mm, 78 mm, 38 mm
72-6694 CAL D
The 72-6694 CAL D from Tenma is a current calibrator. It provides quality and accuracy of handheld calibrator of precision current source. It features large LCD display (maximum display counts 1999, 13mm (0.5") digit size). The current calibrator has 006P DC 9V, MN1604/PP3 battery or equivalent alkaline type or heavy duty type power supply. The dimension is 185mm × 78mm × 38mm (7.3" × 3" × 1.5") and weight is 265g/0.58lb (including battery). It has adjustable 0 to 24mA current source, 2 ranges (0 to 19.99mA (0.01mA display resolution, ±(0.25% FS + 1d) accuracy), 0 to 24mA (0.1mA display resolution, ±(0.5% FS + 1d) accuracy).
-
product
Cable Continuity Tester, VGA/UL2919 Mini, Network, 21.01 mm, 35 mm, 45.01 mm
72-9205
Quickly test VGA / UL2919 cables No need to carry bulky, expensive cable testers to test only one or two cable types Mini cable tester fits easily in your pocket or tool box, and requires no external power Confirms conductor continuity with sequential LED's Save time and money by diagnosing connectivity issues All units are powered by a cross compatible 3xAA battery pack or USB cable (both included) Most units measure 2" x 2" x 1" or less!
-
product
MM Fiber Test
KI-TK032
850/1300 nm source & power meter, inspection microscope, cleaning materials. Interchangeable SC & LC connectors
-
product
Adapter, 2.4 mm (f) to 3.5 mm (m), DC to 26.5 GHz
11901D
The Keysight 11901D is a metrology grade, 2.4 mm female to 3.5 mm male adapter with dc to 26.5 GHz operation.
-
product
Oscilloscope 59 GHz, 2 Channels, 1 mm Inputs
UXR0592BP
The UXR0592BP is the 59 GHz, 2 channel, 1mm input, Infiniium UXR-Series real-time oscilloscope.
-
product
Electronic Calibration Module (ECal), 50 GHz, 2.4 Mm, 2-port
N4693D
The Keysight N4693D microwave electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy, and accurate. The N4693D is a precision 2-port ECal module that supports 2.4 mm connectors up to 50 GHz. Select either female-female, male-male, or female-male connectors. The plastic storage case for the N4693D is included for securing your ECal module and accessories.
-
product
Test Port Adapter Set, 3.5 Mm (Test Port) To Type-N
85130C
The Keysight 85130C test port adapter is designed to protect the test set port when it would be directly connected to the device under test. These adapters have a special rugged female connector designed for connecting to the network analyzer test port. This special connector will not mate with a standard male connector, but converts the rugged test set port to a connection that can be mated with the device under test. The set contains a 3.5 mm to type-N male adapter and a 3.5 mm to type-N female adapter. The frequency range for these adapters is dc to 18 GHz with a return loss of 28 dB or better.
-
product
Electronic Calibration Module (ECal), 18 GHz, 7 Mm, 2-Port
N4696D
The Keysight N4696D microwave electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy, and accurate. The N4696D is a precision 2-port ECal module that supports 7-mm connectors up to 18 GHz. The plastic storage case for the N4696D is included for securing your ECal module and accessories.
-
product
Mini Pneumatic, Contact, ITA, Push-in Fitting, for 4 mm OD Tubing
610132111
Primary mating contact 610131111.Please note: This contact cannot be used to fully populate any compatible VPC module. The larger head size prevents directly adjacent placement.
-
product
Adapter Kit, 3.5 mm
83059K
The Keysight 83059K adapter kit includes the 83059A 3.5-mm male adapter, the 83059B 3.5-mm female adapter, and the 83059C 3.5-mm male to 3.5-mm female adapter.
-
product
Displacement Transducers [mm]
The Displacement Transducers are for use in precision measurement in the m range to simple displacement monitoring during manufacturing and assembly or the supervision of construction projects.
-
product
Cable Continuity Tester, USB 3.0 Mini, Network, 21.01 mm, 45.01 mm, 47.02 mm
72-9210
The 72-9210 is a Mini Cable Tester for USB 3.0 (A/B, A/A, A/micro B) cable. Mini cable tester fits easily in your pocket or tool box.
-
product
6TL-3X INLINE Header Conveyor 765 mm Length
AQ580
- PCB up to 600mm length 400 mm width- Programmable transfer speed up to 1 m/s- Automatic Previous/Next speed adjustment- 2D Code reader w/automatic positioning- Pre-wired for second 2D Code reader- Automatic width setting- PC for line management w/UPS with 20” monitor and keypad in adjustable position arm- 24 Ports PoE Switch- Power inlet rack with current protections and line safety relay- Top cover and door w/safety contacts inhibiting line modules while active- Mechanisms self-test- Width auto-adjustment and cyclic width- Non-contact electronic stop of the PCB- 4U Free on the 19” Rack- Interfaces SMEMA 9851 y IPC-HERMES 9852- CE certified
-
product
NI-9970, 2-Position, Spring Terminal Connector Plug, 3.5 mm Pitch (Qty 4)
787005-01
2-Position, Spring Terminal Connector Plug, 3.5 mm Pitch (Qty 4)
-
product
Adapter, 2.4 mm (f) to 2.4 mm (f), DC to 50 GHz
11900B
The Keysight 11900B is a metrology-grade, 2.4 mm female to 2.4 mm female adapter with dc to 50 GHz operation.
-
product
Adapter, 2.4 mm (f) to APC-7, DC to 18 GHz
11902B
The Keysight 11902B is a metrology grade, 2.4 mm female to APC-7 adapter with dc to 18 GHz operation.
-
product
Light / Lux Meter, 50000 lx, 100 lx, 4 %, 185 mm, 78 mm, 38 mm
72-7250
The 72-7250 is a Digital Light Meter with RS-232 capability. It features super large LCD display with contrast adjustment for best viewing angle. Records maximum, minimum and average readings. Wide range measurement both for LUX and foot candle units. User selectable lighting type (tungsten, fluorescent, sodium or mercury).
-
product
Thermometer, 2 Channel, 0°C to +1767°C, 175 mm, 85 mm, 30 mm
72-7715
Compact handheld thermometer is ideal for a variety of industrial, residential, HVAC and equipment testing applications. It accepts a wide variety of industry standard thermocouple probes and features internal data logging of up to 100 records. Dual inputs allow simultaneous measurement of two separate zones with independent readout or differential (T1-T2) display
-
product
Coaxial Waveguide Adapter, 2.4 mm (m), 33 to 50 GHz
Q281B
The Keysight Q281B is a 2.4 mm male to WR-22 waveguide adapter that operates in the 33 to 50 GHz frequency range. These adapters transform waveguide transmission lines into 50 ohm coaxial lines. Power can transmitted in either direction, and each adapter covers the full frequency range of its waveguide band with SWR less than 1.3.
-
product
Light / Lux Meter, 100000 lx, 100 lx, 5 %, 180 mm, 72 mm, 32 mm
72-6693
The Tenma 72-6693 is a high accuracy Illuminance meter. Featuring a dual function display, this meter can record both maximum, minimum and average readings. User selectable lighting types of tungsten/sun, fluorescent, sodium and mercury.
-
product
Pneumatic Contact, Receiver, Hose Barb, for 1/8" [3.2 mm] ID Tubing
610132105
Primary mating contact 610131106.Pneumatic Connectors are available with either ferruless polytube fittings (3/8" tubing OD) or hose barb (3/8" tubing ID). Ferrules fittings securely attach tubing without hose clamp - which is recommended for the hose barb type (hose clamp not included). The 1/8" ID connectors are available with hose barb.
-
product
Mm Wave Measurement
Erickson PM5B
bsw TestSystems & Consulting AG
Erickson PM5B from VDI, which has been further optimised in the version just presented. The measuring head of the PM5B operates in the WR10 band, i.e. in the 75 - 110 GHz range. High-precision accessories, so-called tapers, provide for adjustments and thus make measurements in the waveguide bands, currently up to WR0.34 beyond 3 THz, possible.





























