MM
-
product
Embedded MXM GPU Module with Embedded NVIDIA RTX™ A1000
EGX-MXM-A1000
- NVIDIA Ampere Architecture- Standard MXM 3.1 Type A (82 x 70 mm)- PCIe Gen 4 x8 interface- 2048 CUDA® cores, 16 RT Cores, and 64 Tensor Cores- 6.66TFLOPS peak FP32 performance- 4GB GDDR6 memory, 128-bit- 192GB/s maximal memory bandwidth- 5-year availability
-
product
Autonomous Data Collector
DCX-16 (VG, SG)
KELLER AG für Druckmesstechnik
The DCX-16 is an autonomous, battery-powered data collector in a stainless steel housing with a very small diameter of only 16 mm. In applications where a small probe diameter is an advantage, the logger can record the water level (pressure) and the temperature over long periods.
-
product
Precision Positioning stage
N-661
Physik Instrumente GmbH & Co. KG
Miniature Linear Stage with NEXACT Drive Travel Range 20 mm Self Locking at Rest, no Heat Generation, no Servo Dither Compact Design: 70 x 50 x 20 mm Zero-Wear Piezo Stepping Drive, Ideal for Micro- and Nano-Manipulation Integrated Linear Encoder Option for Highest Accuracy with 20 nm Resolution Two Operating Modes: Continuous Stepping Mode and Continuously Variable, High-Dynamics Analog Mode for 30 pm Resolution** Up to 10 N Force Generation
-
product
Bottom Electrode SMD Test Fixture
16197A
The 16197A is designed for impedance evaluations of bottom electrode SMDs. It achieves stable frequency characteristics up to 3 GHz and provides highly repeatable measurements. The Keysight 16197A supports various SMD sizes, as small as 1005 (mm)/0402 (inch) and as large as 3225 (mm)/1210 (inch). Accommodation of the 0603 (mm)/0201 (inch) size is available with option 001.
-
product
Industrial Serial GSM Modem
ENVIROMUX-GSM-IND
Sends SMS messages to a pager or cell phone when a sensor goes out of range of a configurable threshold. SIM card supporting SMS messaging required (not included). Ideal for harsh environments and high temperatures up to 149°F (65°C). GSM/GPRS/EDGE 850/900/1800/1900 MHz. AT command compatible. Dimensions: 3.58x2.28x0.87 in (91x58x22 mm). Operating temperature: -13 to 149°F (-25 to 65°C). Operating humidity: up to 95% non-condensing RH. Regulatory approvals: CE, C-Tick. Compatible with ENVIROMUX-SEMS-16(U).
-
product
Long Travel Extensometer
XL
The Instron model XL (long travel) extensometer is a precise device for measuring strain in highly extensible materials such as elastomers, semi-rigid plastics and films. Designed for use with electromechanical testing instruments, Instron XL units can be used to measure specimens elongation's up to 10 in or 250 mm. An optional of 15 in or 375 mm travel is also available.
-
product
Alternate 2.58 (73.00) - 6.00 (170.00) High Performance Lead Free Probe
LFRE-25I40-6
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Industrial Flex ATX AC Power Supply for Mini-ITX Chassis, 250W
APS-925XU (80Plus)
- Power (typical): 250W- AC Voltage Input Range: Universal- Certifications: UL/cUL/TUV/CCC- Dimensions: 150 x 81.5 x 40.6 (mm)
-
product
Cable Assy 37-Pin D-Type M/M 0.5m
40-970-037-0.5m-MM
The 37-Pin D-Type cable assembly is constructed from 19/0.18 (21AWG) Tinned Copper Wire. Screwlocks are provided to secure the cable to its associated products. The 37-Pin Female connector option of this cable assembly is suited for direct connection to Pickering Interfaces products.
-
product
Manual Fixture Kit
230351 – CMK-02
Linear click system with ball bearings, using gas springs.10 mm ESD-proof top cover with aluminum reinforcement bars.Steel base cabinet with detachable aluminum back and bottom panels.Detachable interchangeable case system with an 8 mm spring-loaded probe protection cover.Base cabinet fitted with a telescopic guide rail and catch.
-
product
Coupled Multielectrode Array Sensor (CMAS) Probes
CMAS probes are made from user-specified sensing materials, including carbon steels, stainless steels, and nickel-, aluminum-, and copper-based alloys. They can also be made from customer supplied materials that have the same microstructure/heat treatment as the system component materials to be monitored. The size of the sensing electrode varies from 0.1 to 3 mm (0.004" to 0.12") in diameter, depending on the application. Typical numbers of electrodes in a CMAS probe are 9, 16 or 25 for online corrosion monitoring and vary from 8 to 100 for laboratory corrosion and electrochemical studies.
-
product
Oscilloscope 40 GHz, 4 Channels, 1.85 mm Inputs
UXR0404B
XR0404B Infiniium UXR-Series is the 40 GHz, 4 channel, 1.85 mm input, Infiniium UXR-Series real-time oscilloscope.
-
product
TSP100 Switch Probes
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 20Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 1,990Overall Length (mm): 50.60Switch Point (mil): 59Switch Point (mm): 1.50
-
product
IEC60335-2-9 Clause 3 Figure 104 Vessel For Testing Induction Hotplates
CX-104
Shenzhen Chuangxin Instruments Co., Ltd.
IEC60335-2-9 clause 3 figure 104 Vessel for testing induction hotplates Parameter : Pot and lid material is mainly Q235, carbon mass fraction <0.08%; 2. The thickness of the wall material is 2 mm;3. The bottom of the pot body can not be outward convex, can not exceed 0.05mm; 4. Pot body and lid surface to be clean 5, size: 110, 145, 180, 220, 300mm each one
-
product
PS/2 Type; ATX 400W
PS400-XP2
*Input Range: 90 ~ 264VAC Full Range*Output Voltage:**+5V, 20A (0.5A min)**+3.3V, 20A (0.3A min)**+12V1, 16A (1A min)**+12V2, 16A (1A min)**-12V, 0.5A**+5Vsb, 2.5A (1A min)*MTBF(hours): At 25°C, 100,000h*Safety: TUV, CS22.2 NO.60950-1, IEC, UL, NEMKO+CB, CE*Dimensions: 150 x 140 x 74 mm*Compatible with Axiomtek products: AX61221/AX61222/AX60501/AX60551/AX60552/AX61400/AX6145/AX6156/AX61492/AX61220
-
product
Multimeter Cables
Criem multimeter cables - needle tip cable, 4 mm multilamine tip cable, etc.
-
product
Video Decoders
Video decoders continue to remain in demand in many automotive, professional, and consumer video applications. Analog Devices, an industry leader in the analog video product field, offers a range of video decoders that provide high quality conversion of analog video in standard (SD) and high definition (HD) resolutions to digital video data in MIPI or TTL formats. Typical applications include decoding rear-view camera analog video and audio-video receivers. Our video decoder portfolio’s diverse solutions offer competitive advantages such as automotive qualification, on-chip differential input and diagnostic support, superior 3D-comb performance, and small packages (32-lead, 5 mm × 5 mm LFCSP).
-
product
High 1.73 (49.00) - 8.00 (227.00) High Performance Bias Ball Probe
POGO-1T1-8
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
OX 774 WDM Node
- Two Output - Sensitivity: -16dBm- Output Level: 85 dB- Operates With 12V ONU Adapter- DC to DC Cable-2.5 / 1.5 mm Plug provided- Use with PSP (STB Adapter)
-
product
Ultra High 1.77 (50.00) - 10.00 (283.00) High Performance Lead Free Probe
LFRE-25V-10
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
High 1.73 (49.00) - 8.00 (227.00) High Performance Bias Ball Probe
POGO-1T30-8-S
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Elevated 1.68 (48.00) - 7.00 (198.00) High Performance Lead Free Probe
LFRE-1T24-7
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard 1.10 (31.00) - 3.85 (109.00) Battery Probe
BIP-2
Current Rating (Amps): 5Average Probe Resistance (mOhm): 30Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 365Overall Length (mm): 9.27
-
product
I/O Board With Two COM, Four USB 3.0, One Gigabit LAN, And HDMI For PICO880, PICO500, PICO300
AX93276
*Specifications: 1 x RS-232/422/485, 1 x RS-232, 4 x USB 3.0, 1 x HDMI, 1 x Gigabit LAN, 1 x Power On, 1 x Reset, 2 x LED*Dimensions: 118 x 40 mm*Compliant products: PICO880, PICO500, PICO300
-
product
Supporting Micro Flowrate Range Liquid Chromatography Mass Spectrometry System
Nexera Mikros
Improvement in the sensitivity of an LC/MS/MS method can generally be achieved by reducing the analytical scale of the analysis. However, reducing the analytical scale significantly to nano-flow reduces the throughput, stability, and robustness as a trade-off for greater sensitivity. Nexera Mikros, a Shimadzu microflow LC/MS system, offers a balanced solution to increased sensitivity with less compromise to throughput and robustness, using flow rates from 1 to 500 μL/min and column I.D. from 0.1 to 1 mm. It achieves stable and sensitive quantitative analysis through robust performance of microflow solvent delivery, optimized ion source design, the unique UF-Link column connection, and system variety that supports a wide range of applications.
-
product
Other Switching Power Supplies
PeakTech Prüf- und Messtechnik GmbH
The switching power supply technology used ensures high performance with a small size and low weight. 6 different DC output voltages (3 V / 4.5 V / 6 V / 7.5 V / 9 V and 12 V) can be set using a slider. With the 4 mm pole terminals, you can easily connect single wires but also 4 mm banana plugs. The power cord with an Euro plug is firmly connected to the power supply unit, whereby the device is switched off and on via a rear power switch. This handy power supply fits on every work bench and can be used universally in the hobby area, service or training.
-
product
Elevated 1.68 (48.00) - 7.00 (198.00) High Performance Lead Free Probe
LFRE-1L-7
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25T30-4
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, 3.5 Mm, 2 Port
85093D
The Keysight 85093D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
product
Standard 0.70 (20.00) - 1.30 (37.00) Non Replaceable General Purpose Probe
A-S-C
Current Rating (Amps): 2Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 30Full Travel (mm): 0.76Recommended Travel (mil): 20Recommended Travel (mm): 0.51Overall Length (mil): 230Overall Length (mm): 5.84Rec. Mounting Hole Size (mil): 38Rec. Mounting Hole Size (mm): 0.97Recommended Drill Size: #62 or 0.97 mm





























