Surge Generators
More Info| Related Searches: | Burst Generators, Coupling Networks, High Power Generators, Impulse Generators, Lightning, Pulse Generators, Surge Simulators, Surge Testers, Transient Generators |
|---|---|
| Expand Your Results: | Generators, Surge |
-
PG 10-2500 - Pulse current generator HILO - TEST, Elektrische Prüf- und Messtechnik GmbH Contact Info Send To Colleague The surge current generators PG **-**** generate impulse currents with wave form 10/50 µs - 10/1000 µs acc. to IEC, VDE etc.. Pulse current output amplitude is controlled by preset charging voltage and can be adjusted up to the maximum value of the special type of generator. The generator is designed for testing electrical components, overvolta ...more -
PG 6-250 - Varistor-Tester HILO - TEST, Elektrische Prüf- und Messtechnik GmbH Contact Info Send To Colleague The VARISTOR-TESTER PG 6-250 is a compact test generator for testing the surge current capability of varistors. The unit contains a combination wave generator and a surge voltage generator acc. to CCITT, ITU-T. ...more -
CWG 1500 - Surge / Hybrid Generator Schlöder GmbH Contact Info Send To Colleague Voltage 200 V to 4400 V. Waveshape 1,2 / 50 µs. Current 100 A to 2200 A. Waveshape 8 / 20 µs. Measurement of voltage and current during the discharging. 1phase coupling network 16 A include ...more -
PG 10-10000 - Pulse current generator HILO - TEST, Elektrische Prüf- und Messtechnik GmbH Contact Info Send To Colleague The SURGE TEST GENERATOR PG 10-10000 delivers surge current pulses with the waveform 8/20µs, acc. to IEC 60. It was designed for testing surge protection devices. Moreover the generator can be used for testing two-gap over-voltage protectors. It delivers surge current pulses synchroneous at two impulse current outputs, peak value adjustable 0.5 ...more -
IPG 1201 - Surge test of electrical insulations HILO - TEST, Elektrische Prüf- und Messtechnik GmbH Contact Info Send To Colleague The High-Voltage Pulse Generator IPG 1201 is designed for testing of impulse dielectric strength of components, insulation, air-and surface flash-over gaps. It is specially used for testing surge withstand capability of insulation between accesible parts and hazardous live parts, e.g. terminals for connection of antenne and mains supply tremina ...more -
IPG 1050 - High-voltage Pulse Generator HILO - TEST, Elektrische Prüf- und Messtechnik GmbH Contact Info Send To Colleague HV - Impulse generators IPG 620 and IPG 1050 create standard impulse voltages with wave form 1.2 / 50 µs acc. to IEC 60. The generators simulate surges caused by switching of inductive loads, power system switching, lightning strokes etc. ...more -
PG 6-400 - Surge current generator HILO - TEST, Elektrische Prüf- und Messtechnik GmbH Contact Info Send To Colleague The high-current pulse generators PG 6-200 / PG 6-400 are designed for surge testing of electrical components, over-voltage protectors and electronic circuits acc. to IEC, VDE etc. ...more -
IPG 620 - High-voltage Pulse Generator HILO - TEST, Elektrische Prüf- und Messtechnik GmbH Contact Info Send To Colleague HV - Impulse generators IPG 620 and IPG 1050 create standard impulse voltages with wave form 1.2 / 50 µs acc. to IEC 60. The generators simulate surges caused by switching of inductive loads, power system switching, lightning strokes etc ...more -
Transient Series, TRA2000 EMC Partner AG Contact Info Send To Colleague Full Compliance CE Mark test equipment and ANSI transient test solutions. Choice of 4kV or 6kV SURGE generators with Combination, 100 kHz Ring, and 10/700 waves plus your choice of ESD, EFT, and voltage DIPS and Interrupts as needed. Integrated, automated, single phase CDN. ...more -
Galaxy 4000 UPS (40-75 kVA) MGE UPS Systems Contact Info Send To Colleague The Galaxy 4000 separates itself from other UPS modules with technology that increases performance and reliability, all at a competitive cost. The Galaxy 4000’s IGBT rectifier significantly minimizes input harmonics and the Power Factor Corrected Input reduces installation costs thanks to smaller cabling and generator costs. Unmatched fr ...more -
PS 3/6/12 Surge Generator InterEng GmbH Contact Info Send To Colleague The 12 kV surge generator is used for cable fault location in low and medium voltage networks. It generates high energy surge waves up to a voltage of 12 kV. ...more -
PS 6/12/24 Surge Generator InterEng GmbH Contact Info Send To Colleague The 24 kV surge generator is used for cable fault location in low and medium voltage networks. It is equipped with three motorised switchable surge levels for use in cable networks with low nominal voltage. ...more -
PS3-PS4 Surge Generators InterEng GmbH Contact Info Send To Colleague The PS 3 - PS 4 surge generator is used for the cable fault location in low and medium voltage networks with low nominal voltage. It generates high energy surge waves up to a voltage of 3 kV with 450 J or 4 kV with 500 J. ...more
|
Definition: Equipment capable of simulating the types of surges (such as lightening) that impinge upon equipment in the real world. (www.powerquality.com) These generators are used in destructive tests to record the type and extent of damage experienced by various types of electrical equipment when exposed to surges in electrical power. |