Showing results: 601 - 615 of 1987 items found.
-
192061-05 -
NI
68-Pin Male VHDCI to 68-Pin Female D-SUB, Twisted Pair, Shielded Multifunction Cable - The SH68M-68F-EPM Cable, sometimes referred to as SHC68-68-EPM, connects DAQ devices to accessories or cables with D-SUB connectors. You can use this cable to create custom cabling for your DAQ device. The SH68M-68F-EPM Cable is offered in different lengths.
-
192061-10 -
NI
68-Pin Male VHDCI to 68-Pin Female D-SUB, Twisted Pair, Shielded Multifunction Cable - The SH68M-68F-EPM Cable, sometimes referred to as SHC68-68-EPM, connects DAQ devices to accessories or cables with D-SUB connectors. You can use this cable to create custom cabling for your DAQ device. The SH68M-68F-EPM Cable is offered in different lengths.
-
782536-01 -
NI
68-Pin Female Screw Terminal to 68-Pin Female D-SUB, DIN-Rail, Shielded I/O Connector Terminal Block - The SCB-68A provides a shielded I/O connection for interfacing I/O signals to plug-in data acquisition devices with 68-pin connectors. This Terminal Block combines with shield cables to provide low-noise signal termination. The SCB-68A incorporates a completely redesigned mechanical enclosure with a magnetic removable lid, DIN-rail mount compatibility, and a resettable fuse. It is compatible with single- and dual-connector Multifunction I/O with 68-pin connectors. The SCB-68A also includes two general-purpose breadboard areas and an onboard cold-junction compensation sensor.
-
777145-01 -
NI
68-Pin Female VHDCI to 68-Pin Female Screw Terminal, Desktop Mount Terminal Block - The CB-68LP features 68 screw terminals for easy connection of field I/O signals to 68-pin NI data acquisition devices. It includes one 68-pin male SCSI connector for direct connection to 68-pin cables. This connector block features standoff feet for use on a desktop or mounted in a custom panel. The CB-68LP also has a vertical-mounted, 68-pin connector.
-
187252-0R25 -
NI
68-Pin Female to 68-Pin Female, 1 Ribbon Connection Ribbon Cable - The R68F-68F Cable, sometimes referred to as the R68-68 or RC68-68, is a flat ribbon cable that connects to 68-pin NI data acquisition or digital I/O devices. The R68F-68F Cable is offered in different lengths and with D-SUB or VHDCI front end connectors.
-
777145-02 -
NI
68-Pin Female VHDCI Right Angle to 68-Pin Female Screw Terminal, Desktop Mount Terminal Block - The CB-68LPR is a terminal block with 68 screw terminals for easy connection of field I/O signals to 68-pin NI data acquisition devices. It includes one 68-pin male connector for direct connection to 68-pin cables. This CB-68LPR features standoff feet for use on a desktop or mounted in a custom panel. The CB-68LPR also has a right-angle-mounted, 68-pin connector.
-
187252-0R5 -
NI
68-Pin Female to 68-Pin Female, 1 Ribbon Connection Ribbon Cable - The R68F-68F Cable, sometimes referred to as the R68-68 or RC68-68, is a flat ribbon cable that connects to 68-pin NI data acquisition or digital I/O devices. The R68F-68F Cable is offered in different lengths and with D-SUB or VHDCI front end connectors.
-
187252-01 -
NI
68-Pin Female to 68-Pin Female, 1 Ribbon Connection Ribbon Cable - The R68F-68F Cable, sometimes referred to as the R68-68 or RC68-68, is a flat ribbon cable that connects to 68-pin NI data acquisition or digital I/O devices. The R68F-68F Cable is offered in different lengths and with D-SUB or VHDCI front end connectors.
-
182482-0R25 -
NI
68-Pin Female to 68-Pin Female, 1 Ribbon Connection Ribbon Cable - The R68F-68F Cable, sometimes referred to as the R68-68 or RC68-68, is a flat ribbon cable that connects to 68-pin NI data acquisition or digital I/O devices. The R68F-68F Cable is offered in different lengths and with D-SUB or VHDCI front end connectors.
-
182482-01 -
NI
68-Pin Female to 68-Pin Female, 1 Ribbon Connection Ribbon Cable - The R68F-68F Cable, sometimes referred to as the R68-68 or RC68-68, is a flat ribbon cable that connects to 68-pin NI data acquisition or digital I/O devices. The R68F-68F Cable is offered in different lengths and with D-SUB or VHDCI front end connectors.
-
777960-01 -
NI
68-Pin Female SCSI to Female BNC and Screw Terminal, DIN Rail, Desktop Mount, Shielded Terminal Block - The BNC-2120 can be used with various NI multifunction I/O and analog output devices. The BNC-2120 simplifies the connection of analog signals, some digital signals, and two user-defined connections to the data acquisition device while maintaining the integrity of your measurements with a shielded enclosure. It also features a function generator, quadrature encoder, and cold junction compensation for thermocouple measurements. The BNC-2120 includes a DIN Rail and a desktop mount option.
-
778289-01 -
NI
68-Pin Female SCSI to Female BNC and Screw Terminals, Function Generator and Encoder, Desktop Mount, Shielded Terminal Block - The BNC-2121 features eight dedicated and six user-defined BNC connectors and spring terminals, which allow access to all I/O signals. You can also use this terminal block to provide pulse-train, trigger, and quadrature encoder signals. The BNC-2121 includes a desktop mount.
-
777141-01 -
NI
68-Pin Female SCSI to 68-Pin Female Screw Terminal, DIN Rail Terminal Block - The TBX-68 provides 68 screw terminals to connect field I/O signals to 68-pin NI data acquisition devices. It includes one 68-pin male SCSI connector for direct connection to 68-pin cables. The TBX-68 is mounted in a protective plastic base with hardware for mounting on a standard DIN rail.
-
187051-01 -
NI
68-Pin Female SCSI to 68-Pin Right-Angle Female SCSI, Twisted Pair, Shielded, 1 m Multifunction Cable - The SH68F-68R1F-EP Cable, sometimes referred to as SH68-68R1-EP, connects NI DAQ 68-pin devices to 68-pin accessories. The right-angle connector is useful for small spaces where clearance is limited.
-
778967-01 -
NI
64-Channel, ±30 VDC, Sink/Source Inputs, Bank-Isolated PXI Digital I/O Module—The PXI‑6511 is an industrial digital input interface, with eight banks of isolated channels. If a computer or application fault occurs, the PXI‑6511 can use digital I/O watchdogs to switch to a configurable safe output state to ensure detection and safe recovery from fault conditions. Programmable input filters eliminate glitches/spikes and provide debouncing for digital switches/relays through a software-selectable digital filter.