Showing results: 1291 - 1305 of 1987 items found.
-
782385-12 -
NI
The TB-2645B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire 16x16 or 1-wire dual 16x16 matrix. You can directly connect the TB-2645B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2645B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
782385-10 -
NI
The TB-2644B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire 8x32 or 1-wire dual 8x32 matrix. You can directly connect the TB-2644B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2644B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
782385-14 -
NI
The TB-2646B provides the necessary routing to configure the PXI-2532B or PXIe-2532B PXI Matrix Switch Module as a 2-wire dual 4x32 or 1-wire quad 4x32 matrix. You can directly connect the TB-2646B to the front panel I/O connectors of the PXI-2532B or PXIe-2532B. This terminal block includes ribbon cable headers to connect signals to the PXI Matrix Switch Module. The TB-2646B also provides optional isolation resistors to protect the reed relays from capacitive loads.
-
779295-01 -
NI
80 AI (16-Bit, 250 kS/s), 2 AO, 24 DIO PCI Multifunction I/O Device - The PCI‑6225 offers analog I/O, correlated digital I/O, two 32-bit counters/timers, and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.
-
779624-01 -
NI
8 AI (16-Bit, 250 kS/s), 2 AO, 6 DI, 4 Sourcing DO, Bank-Isolated, PXI Multifunction I/O Module—The PXI‑6238 is a bank-isolated DAQ device designed for current I/O. It offers analog I/O, digital input, sourcing digital output, two 32‑bit counters, and digital triggering. The digital input and outputs are compatible with 24 V signals. It combines the safety and performance benefits of isolation with high-performance timing, amplification, and calibration technologies to offer accurate measurements and precise control. The PXI‑6238 is ideal for test, measurement, control, and design applications in environments with high voltages and electrical noise. You can use the PXI‑6238 to read from encoders, flow meters, and proximity sensors as well as control valves, pumps, and relays.
-
784554-01 -
NI
The acA1920-150um is a Monochrome Basler Ace USB3 Vision Camera with a 2.3 MP resolution and a maximum image acquisition speed of 150 frames per second. … The acA1920-150um uses a PYTHON 2000 sensor and is quality tested and calibrated for high performance and reliability. This camera can be used with NI hardware and software to build machine vision systems.
-
785902-01 -
NI
The acA1920-40gm is a Monochrome Basler Ace GigE Vision Camera with a 2.3 MP resolution and a maximum image acquisition speed of 40 frames per second. … The acA1920-40gm uses a IMX249 sensor and is quality tested and calibrated for high performance and reliability. This camera can be used with NI hardware and software to build machine vision systems.Read Less
-
787073-01 -
NI
The acA1440-220um is a Monochrome Basler Ace USB3 Vision Camera with a 1.6 MP resolution and a maximum image acquisition speed of 220 frames per second. … The acA1440-220um uses a IMX273 sensor and is quality tested and calibrated for high performance and reliability. This camera can be used with NI hardware and software to build machine vision systems.
-
785900-01 -
NI
The acA1920-155um is a Monochrome Basler Ace USB3 Vision Camera with a 2.3 MP resolution and a maximum image acquisition speed of 155 frames per second. … The acA1920-155um uses a IMX174 sensor and is quality tested and calibrated for high performance and reliability. This camera can be used with NI hardware and software to build machine vision systems.
-
787064-01 -
NI
The acA1440-73gm is a Monochrome Basler Ace GigE Vision Camera with a 1.6 MP resolution and a maximum image acquisition speed of 73 frames per second. … The acA1440-73gm uses a IMX273 sensor and is quality tested and calibrated for high performance and reliability. This camera can be used with NI hardware and software to build machine vision systems.
-
782142-01 -
NI
The acA2000-340km is a Monochrome Basler Ace Camera Link Camera with a 2 MP resolution and a maximum image acquisition speed of 340 frames per second. … The acA2000-340km uses a CMV2000 sensor and is quality tested and calibrated for high performance and reliability. This camera can be used with NI hardware and software to build machine vision systems.
-
154302-01 -
NI
Low Profile I/O Cable, 37-pin Female DSUB to Male DSUB (1m)
-
154742-01 -
NI
Low Profile I/O Cable, 25-Pin Female DSUB to Male DSUB (1m)
-
196648-05 -
NI
M12 Cable, 2-Pin Female Connector to Pigtail, 5 m
-
779501-01 -
NI
MXI-Express Interface, PXI Remote Control Module—The PXI‑8360 allows you to control PXI and CompactPCI systems from your PC using a fully transparent MXI‑Express link. It is installed in a PXI chassis and uses a PCI Express‑to‑PCI bridge to interface with an installed PCI‑8360 through a copper, x1 MXI‑Express cable.