Filter Results By:
Products
Applications
Manufacturers
Total Harmonic Distortion
Is a measure of a signal's sum power of all harmonic components to the power of the fundamental frequency.
See Also: Distortion, Intermodulation Distortion, THD
-
product
Clamp-on Meter
SDC96
True RMS for AC measurement. Total harmonic distortion [50Hz/60Hz] for AC. Measurement. Peak measurements. Measures up to 700 AC/DC amps
-
product
Operational Amplifiers
Operational amplifiers from ams are ideally suited to audio applications. These CMOS devices are available as single, quad or differential amps. They feature good common-mode rejection, have low input bias currents, good gain bandwidth, low total harmonic distortion and an excellent rail-to-rail output-drive capability of 200mA peak.
-
product
Power Quality Analyzer
Power quality analyzer is a product carefully developed by our company and specially designed for field test of three phases, multi-functional and intelligent, man-machine operation and concise and comprehensive test instrument. It is easy to use, large LCD screen display, high resolution, interface in both Chinese and English, shock-proof shell structure and so on. Can simultaneously measure the 4-channel current (ABC three phase and neutral wire current), 4-channel voltage (ABC three-phase voltage and neutral line voltage to ground), the peak value of current voltage, maximum/minimum value over a period, three-phase imbalance factor, short-time voltage flicker, transformer K factor, active power, reactive power, apparent power, power factor and displacement power factor, active power, reactive power, apparent power, total harmonic distortion and harmonic, etc; Display real-time waveform, harmonic ratio bar charts of current voltage; Dynamically capture instantaneous change of voltage current, monitoring starting current, monitoring the power parameters and generate the alarm list, generate the trend chart for a long time record test data.
-
product
AC Power Source, Frequency Converter
BL1350 Series
Behlman's BL1350 AC Power Supply / Frequency Converter / Inverter, requires just 3.5" of rack height, and weighs as low as 45 pounds, yet it delivers 1350 VA of quality AC power. In the BL 1350, you'll find the quality features you expect from Behlman, fully adjustable frequency and voltage, total harmonic distortion of less than 0.5%, high efficiency, plus excellent line and load regulation.
-
product
LCD Power Meters
Accuracy ±0.1% F.S. Measuring and display ACV/ACA/Watt/Var/VA/Power Factor/Frequency/KWH/DM(Demand) Input measurement network can be selectives(1P2W/1P3W/3P3W/3P4W) CT rate/PT rate can be modified(1 to 9999) Measuring ACV/ACA total harmonic distortion(THD),up to 35th harmonic(optional) Two alarm control function (optional) Two pulse output function (optional) Digit RS-485 interface function (Optional)
-
product
Power Quality Meter
Qualstik
The Qualstik Power Quality Meter has been developed specifically for measurement of four important items of power quality in the electric utility industry. These are Current, True Power Factor, Total Harmonic Distortion and the Direction of Current Flow.
-
product
Adjustable High Frequency Reference Ballast
HCS-109A
HCS-109A Adjustable High Frequency Reference Ballast also called High Frequency Current Source. Comparing to IEC Test Method, HCS-109A is an Equivalent Test Method which is economic solution. HCS-109A equipped with Spectrophotometer & Integrating Sphere Test System. It can also measure the photo, color and electricity parameters for high frequency fluorescent lamp.Specifications: • Input voltage: 200V~240V, 50/60Hz • Input Power: 80 W max • Output Current: 130mA~400mA (Adjustable), accuracy: +/- 1% • Output Frequency: 25kHz< +/-2.0% (Adjustable), accuracy: +/- 0.3kHz • Output current total harmonic wave distortion: THD<2.5% (HF current wave)
-
product
Power Analyzers & Wattmeters
Measurements International Ltd.
Direct Replacement for 2010A Wattmeter in the AccuLoss® Loss Measurement Systems, Basic Power Accuracy < 0.005 %, 10 Current Ranges, 2 Voltage Ranges, Line-and-Line and Line-to-Ground Voltage Measurements, Full Power Factor Range, Complete Waveform Analysis, Total Harmonic Distortion Analysis, Phasor Analytical Representation.
-
product
G.fast Transformers
Our line of G.fast transformers are the preferred choice of engineers seeking the most reliable, functional isolation transformers for G.fast transmission. These compact transformers deliver excellent longitudinal balance and total harmonic distortion performance.
-
product
Ultra-Low Distortion Function Generator
DS360
Stanford Research Systems, Inc.
The performance of a low distortion analog source and the precision of direct digital synthesis (DDS) is combined in the DS360. With less than 0.001 % total harmonic distortion (THD), 25 ppm frequency accuracy, and a broad range of features including sweeps and bursts, the DS360 is the ideal source for audio frequency applications.
-
product
mAEStro Audio Analog to Digital Converter
The mAEStro AADC-100 accepts balanced stereo analog audio inputs and converts them into a single digital bit stream in compliance with the AES/EBU (AES3) and S/PDIF digital audio standards. It generates 24-bit values and uses 128 times over-sampling for extremely accurate and linear analog to digital conversion, as well as offering a high dynamic range with exceptionally low total harmonic distortion and noise.
-
product
AC / DC Digital Power Analyzer
4016(800Vp,20Arms/200Ap)
To analyze AC/DC power source, it requires a lot of parameters. Such as voltage(V), current(A), power factor(PF), Total Harmonic Distortion(THD), Crest Factor(CF), Inrush current, etc. To meet power saving regulation, the standby power measurement must be done. In this video I will show you how to operate this Prodigit Power Analyzer 4016. Furthermore, I explain what the parameter's meaning.
-
product
Digital Power Meter (High Accuracy Model)
LS2050
LS2050 digital power meter is a new generation intelligent product which adopts digital sampling technology to analysis of the waveform. It has the following features: • Three windows digital display which reduces reading error, intuitive and convenient • Adopts high speed MCU and high precision A/D to control and measurement • All measured data as virtual value, also suit to signal waveform distortion • Fast test • Equipped with RS232 communicate function, can use upper computer software to carry on remote operation, control and read corresponding data, the test data and waveform could be displayed in the PC, Chinese and English operation interface, high intelligent instrument • This instrument provides two kinds of method to calculate total harmonic distortion (THD), IEC and CSA.
-
product
AC-DC Power Supply Solutions
Advanced Conversion Technology, Inc
From single to three phase inputs, 60 Hz or 400 Hz, ACT can provide you with a design to meet your demanding applications. ACT can also provide designs that incorporate an active PFC front end, single and three phase, which provides less than 3% total current harmonic distortion.
-
product
Distortion Test Sets
DTS-C
Matrix Test Equipment Incorporated
The Model DTS Distortion Test Sets combine Matrix products with those of other manufacturers. When properly equipped, a Model DTS can measure virtually any parameter important to the CATV industry. Controlled completely through the (GPIB) IEEE-488 bus interface, a Model DTS allows rapid, repetitive, and objective readings in a production-type environment.
-
product
Total Sulfur Analyzer
Model T108
Teledyne Advanced Pollution Instrumentation
The Model T108 Total Sulfur analyzer is designed to measure mixed sulfur impurities, collectively referred to as Total Sulfides, in air or carbon dioxide gas. Since there is no scrubber in the system, the instrument reading is the sum of the oxidized sulfur compounds and SO2.The Model T108 consists of a modified Model T100 SO2 analyzer with special software and a Model 501TS high temperature thermal oxidizer. Sulfur compounds are heated as they pass through the converter and oxidized into SO2. When analyzing CO2, which generally contains no oxygen, approximately 6% O2 is added to the sample before entering the converter. This dilution is corrected in the calibration procedure.
-
product
Energy and Harmonics Analyzer
STAR3
STAR 3 is a high quality 96x96mm panel energy analyser provides brilliant features at a price never reached before. The new bright red LCD display, the harmonic analysis, the wide set of measured parameters including the THD available in all the models, the multi-protocol capability of the RS485 port and the high accuracy class 0.5%, the 3 years-warranty period, allow to consider the STAR 3 the new state of art of the panel analysers market
-
product
Harmonic Analysis Software
HI_WAVE
HI_WAVE simulates resonance and harmonic distortion in industrial, commercial, and utility power systems.
-
product
Intermodulation Distortion Measurements
S93087B
The S93087B intermodulation distortion (IMD) measurement makes it very easy to set-up and calibrate swept IMD measurements with a spectrum-analyzer-like display. Not available with Option 200, 210, 400 and 410.
-
product
Condenser for Harmonic Protection
FMLF 7%
Lifasa - International Capacitors, SA
These LIFASA capacitors are designed to be connected in series with INR or INA reactors, and thus form a harmonic filter tuned to a frequency of 189 Hz (lower than the first harmonic present in the network). The nominal powers of the filters indicated in the table are obtained by being connected to the reactors.
-
product
Harmonic Filter Resistors
The widespread use of nonlinear loads such as power electronics based equipment and electric arc & ladle melt furnaces all around the world hinder the quality of electric power. One of the most important parameters for defining the power quality is harmonic distortion.
-
product
Modulation Distortion Up To 125 GHz
S930712B
S930712B enables fast and accurate active device modulation distortion characterization under modulated stimulus conditions up to 125 GHz. The wide dynamic range and vector error correction of the PNA-X results in an extremely low residual EVM of the test setup, delivering you a complete picture of your device’s performance without test system interference. S93072B measures EVM, NPR, ACPR, and decomposes nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.
-
product
Solar Total Pyranometers
SK08 & SK08-E
The Middleton SK08 is an affordable pyranometer for the measurement of global solar irradiance on a plane surface. It meets the international accepted specifications for a good quality pyranometer. The SK08 incorporates a passive thermoelectric sensor. The SK08-E version has an inbuilt signal amplifier.
-
product
Modulation Distortion Up To 50 GHz
S930705B
S930705B enables fast and accurate active-device modulation distortion characterization under modulated stimulus condition up to 50 GHz. The wide dynamic range and vector error correction of the PNA-X result in an extremely low residual EVM of the test setup, so you can get a complete picture of your device’s performance without test system interference. S930704B can measure EVM, NPR, ACPR, and can decompose nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.
-
product
Modulation Distortion Up To 90 GHz
S930709B
S930709B enables fast and accurate active device modulation distortion characterization under modulated stimulus conditions up to 90 GHz. The wide dynamic range and vector error correction of the PNA-X results in an extremely low residual EVM of the test setup, delivering you a complete picture of your device’s performance without test system interference. S930709B measures EVM, NPR, ACPR, and decomposes nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.
-
product
Intermodulation Distortion Measurements
S96087B
Easily set up and calibrate swept intermodulation distortion measurements (IMD) measurements using the S96087B software application with the ENA
-
product
Harmonic Clam Meter
TES Electrical Electronic Corp.
Analysis for 3p4W, 3P3W, 1P2W, 1P3W. True RMS VAlue. Active Pwer. Apparent and reactive pwer. Power FActor, Phase angle.
-
product
Modulation Distortion Up To 70 GHz
S930707B
S930707B enables fast and accurate active-device modulation distortion characterization under modulated stimulus condition up to 70 GHz. The wide dynamic range and vector error correction of the PNA-X result in an extremely low residual EVM of the test setup, so you can get a complete picture of your device’s performance without test system interference. S930707B can measure EVM, NPR, ACPR, and can decompose nonlinear signals and linear signals with the spectral correlation between input and output spectrum without doing demodulation. Integration with the PNA-X SCCM provides quick modulation distortion measurements while making other VNA measurements.
-
product
Total Hydrocarbon Analyzer
Model 4030
Teledyne Analytical Instruments
The Model 4030 uses a field proven FID detector in a heated chamber. The chamber is heated to a high temperature to meet US EPA requirements for VOC emissions monitoring.
-
product
Automated Total Nitrosamine Analyser
Ellutia Chromatography Solutions
Nitrosamines are carcinogenic compounds that can be found and formed in many products. This has been a particular issue in the pharmaceutical industry recently. Traditional approaches to the analysis, such as by mass spec, have been challenging due to the low detection levels required, the possibility of false positives, or even missing. This system takes a unique approach of using the combination of a chemical reaction targeting nitrosamine compounds, then detection by a detector with very high selectivity and sensitivity for nitro/nitroso compounds. Rather than speciating the various nitrosamines present, the system gives a single quantitative result down to 1 ppb for the total nitrosamine content. This means both volatile and non-volatile nitrosamines are measured at the same time. This process is automated to allow a high sample throughput. This makes it ideal for screening a large number of samples rapidly.