Thermocouple Simulators
- Pickering Interfaces Inc.
product
PXI/PXIe Battery Simulator Module, 2-Channel, V/I Readback, Simplified Current Sink, 750 V Isolation
41-752A-913
Targeting EV, automotive, aerospace, energy storage and electric aircraft applications, the new battery simulator modules occupy a single PXI slot. These 2-channel battery simulators are capable of supplying up to 7 V and 300 mA per channel. The channels are fully isolated from ground and from each other, allowing series connection to simulate batteries in a stacked architecture.
-
product
PXI Thermocouple Simulators
Our PXI Millivolt Thermocouple Simulator modules provide 32, 24, 16 or 8 channels of accurate low sources. They are ideal for the simulation of thermocouples and can be used for sensor emulation in ECU testing. The channels can be operated with one of three voltage ranges covering most thermocouple types. We can also supply connection solutions allowing the easy integration of the Thermocouple Simulator into your test system.
-
product
Calibration Cable, 78-pin D-type, Thermocouple Simulator Modules
40-975-078-1m
This cable assembly is specifically designed to connect to the 78-Pin D-Type port on the front panel of Pickering Interfaces Thermocouple Simulator Modules 41-760 and 41-761 enabling calibration via an external DMM.
-
product
PXI Simulation Modules For Sensor Simulation
PXI simulation solutions for sensor simulation, including PXI Programmable Resistors—ideal for the simulation of resistive sensors and PXI Thermocouple Simulators—these provide multiple low-voltage sources ideal for simulating the operation of a thermocouple. Take a look below for all of our PXI Simulation Solutions, we also offer some of these in PCI format as well . All of our PXI simulation cards are supplied with comprehensive software drivers for Windows® XP/Vista/7/8, Lab Windows / CVI and LabView. The Pickering IVI drivers also fully support National Instruments' Switch Executive.
-
product
PXI Isolated Millivolt Thermocouple Simulator - 32 Channel
41-761-001
The 41-761-001 is a low voltage 32-channel output module ideal for simulating theoperation of a thermocouple, also available with 24, 16 or 8 channels. Each channel of the 41-761 provides a low voltage output across two connector pins capable of providing ±20mV with 0.7μV resolution, ±50mV with 1.7μV resolution and ±100mV with 3.3μV resolution, covering most thermocouple types.
-
product
LXI And LXI/USB Modular Chassis
Our LXI modular chassis are available in 7 and 18-slot and our LXI/USB modular chassis are available in 2, 4 and 6-slot and support over 1,000 of our PXI modules. The PXI modules supported range from: PXI general purpose relays, matrices, multiplexers and RF switches to special PXI switching functions such as fault/signal insertion. Also supported are a selection of simulation modules such as programmable resistors, digital I/O, power supplies, thermocouple simulators, function generator, battery simulators and attenuators. This gives you enormous flexibility to define a switching or T&M system to exactly match your needs.
-
product
PXI Millivolt Thermocouple Simulator Module - 24 Channel
41-760-002
This series of PXI Thermocouple Simulator Modules is available in a choice of 32, 24, 16 or 8 channels—each channel providing a low-voltage output across two connector pins capable of providing ±20mV with 0.7µV resolution, ±50mV with 1.7µV resolution and ±100mV with 3.3µV resolution, covering most thermocouple types.
-
product
PXI Isolated Millivolt Thermocouple Simulator - 16 Channel
41-761-003
The 41-761-003 is a low voltage 16-channel output module ideal for simulating theoperation of a thermocouple, also available with 32, 24 or 8 channels. Each channel of the 41-761 provides a low voltage output across two connector pins capable of providing ±20mV with 0.7μV resolution, ±50mV with 1.7μV resolution and ±100mV with 3.3μV resolution, covering most thermocouple types.
-
product
Thermocouple Calibrators
Practical Instrument Electronics, Inc.
PIE has a thermocouple calibrator to fit your needs from the PIE 520B single type thermocouple simulator to the advanced troubleshooting capabilities of the PIE 422Plus. Have you had issues in the past where your thermocouple calibrator wouldn’t work with some of the instruments in your plant? Our thermocouple calibrators are guaranteed to be compatible with all process thermocouple inputs including all brands of smart temperature transmitters, PLC input cards, DCS systems and multichannel recorders.
-
product
Compensation Block for Thermocouple Simulator Modules
40-965-912
The Compensation Block is a accessory specifically designed for the 41-760 and 41-761 Millivolt Thermocouple Simulator modules. This block will give the user the temperature of the front panel junction of the module to cabling. This data can then be combined with other factors, temperature on the other end of the cable for example, to compensate the thermocouple hence increase the accuracy.
-
product
Thermocouple Simulator Module for SLSC
Bloomy’s 8-Channel Thermocouple Simulator Module provides eight channels of galvanically-isolated thermocouple simulation and simulates types E, J, K, M, N, and T thermocouples. High-precision digital-to-analog converters which are isolated from each other and from system power provide sub-microvolt resolution and accuracy. Built-in switching provides open-circuit faults as well as switching to system calibration resources.
-
product
16-Channel VME Analog Output/Thermocouple Simulator Module
V470
The V470 is a 6U VME module that provides sixteen independent, isolated analog outputs that may be user-programmed to operate as voltage outputs or thermocouple simulators. Users may write temperature or voltage values at VMEbus speed, and the microprocessor will transparently do all necessary calculations and update the channel electronics.
-
product
PXI Millivolt Thermocouple Simulator Module - 32 Channel
41-760-001
This series of PXI Thermocouple Simulator Modules is available in a choice of 32, 24, 16 or 8 channels—each channel providing a low-voltage output across two connector pins capable of providing ±20mV with 0.7µV resolution, ±50mV with 1.7µV resolution and ±100mV with 3.3µV resolution, covering most thermocouple types.
-
product
PXI Isolated Millivolt Thermocouple Simulator - 24 Channel
41-761-002
The 41-761-002 is a low voltage 24-channel output module ideal for simulating theoperation of a thermocouple, also available with 32, 16 or 8 channels. Each channel of the 41-761 provides a low voltage output across two connector pins capable of providing ±20mV with 0.7μV resolution, ±50mV with 1.7μV resolution and ±100mV with 3.3μV resolution, covering most thermocouple types.
-
product
PXI Isolated Millivolt Thermocouple Simulator - 8 Channel
41-761-004
The use of two wire outputs and isolation from ground ensures that the 41-761 can be used to accurately simulate low voltages even in the presence of common mode voltages in the system. Each Vcold connection is independent permitting the 41-761 to be connected to multiple cold junctions.
-
product
PXI Millivolt Thermocouple Simulator Module - 8 Channel
41-760-004
This series of PXI Thermocouple Simulator Modules is available in a choice of 32, 24, 26 or 8 channels—each channel providing a low-voltage output across two connector pins capable of providing ±20mV with 0.7µV resolution, ±50mV with 1.7µV resolution and ±100mV with 3.3µV resolution, covering most thermocouple types.
-
product
Engine Speed Control and Measurement (Test Set A)
MS 1100
*Checks the parameters such as current, voltage, speed, and turbine gas temperature of 804E and 811 engines Portable instrument*Testing of Automatic engine control system and after burner control system*Simulates the temperature signal derived from the engine TGT (Temperature Gas Turbine) thermocouples*Simulates the speed signal, NL (low pressure shaft speed signal) drive from the L.P shaft Probe*Indicates the current signal to the FCU solenoid derived from the engine control amplifier*Measure t...show more -
product
PXI Millivolt Thermocouple Simulators
Series 41-760
This series of PXI Thermocouple Simulator Modules is available in a choice of 32, 24, 16 or 8 channelseach channel providing a low-voltage output across two connector pins capable of providing 20mV with 0.7V resolution, 50mV with 1.7V resolution and 100mV with 3.3V resolution, covering most thermocouple types. These thermocouple simulators use two wire outputs with a remote output reference sense to ensure the modules deliver accurate low-level voltages, even if the system has common mode voltages present. In addition, each simulation channel is also able to provide an open circuit setting to simulate faulty wiring connections to a sensor.
-
product
PXI Millivolt Thermocouple Simulator Module - 16 Channel
41-760-003
This series of PXI Thermocouple Simulator Modules is available in a choice of 32, 24, 16 or 8 channels—each channel providing a low-voltage output across two connector pins capable of providing ±20mV with 0.7µV resolution, ±50mV with 1.7µV resolution and ±100mV with 3.3µV resolution, covering most thermocouple types.
-
product
PXI RTD Simulator Module 18-Channel PT1000
40-262-002
The 40-262 is a 3U PXI module range that supports 6 (in one slot), 12 or 18 (in two slots) channels of RTD simulation. Based on the 40-260 design principles the module can provide a setting resolution of <8mΩ (PT100) or <90mΩ (PT1000) and a resistance accuracy of better than 0.1% on all channels. Each simulation channel is able to provide a short or open circuit setting to simulate faulty wiring connections to a sensor. Calibration or verification of each resistor channel can be verified by using the calibration port connected to a high performance DMM and a supplied software package.
-
product
Single Stream STANAG3910/EFEX Test And Simulation Module for PCI
APXX3910
STANAG3910/EFEX Test and Simulation module for PCI with 1 dual redundant HS/LS channel and onboardFibre Optic Front End (FOFE). Easily select between EFAbus and EFEX modes for Tranche II Eurofighter. The APXX3910 is a functional replacementfor model APX3910.
-
product
Synchro Simulator
SPA-CASE
Computer Conversions Corporation
The Synchro Simulator has two modes of operation: Static and Dynamic. The mode of operation is selected by the position of the mode switch. In the static mode, the thumbwheel switches select the output angle. In the dynamic mode, the speed and direction switches determine the rate and direction of synchro outputs. Self test circuitry continuously monitors and displays the output.
-
product
PXI Battery Simulator Module
41-751-001
The 41-751 is a low power battery simulator module that can be used to simulate the power supplies of cellular phones and other portable battery devices. It features fully floating output terminals than can deliver voltages up to 6 Volts. The fast responding remote sense connections allow the module to regulate the supply voltage at the device under test.
-
product
PXI/PXIe Resolver Simulator Module, 4-Banks
43-670-201-AABBCC
The 41/43-670-201 is ideal for the simulation of Resolvers. It has four banks, each capable of simulating the output of a single 5 or 6-wire resolver.
-
product
PXI RTD Simulator Module, 4 Channel, PT100
40-263-501
The 40-263-501 is a 4-channel PT100 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
product
PXI RTD Simulator Module, 24 Channel, PT500
40-263-002
The 40-263-002 is a 24-channel PT500 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
product
Thermocouple, ITA, 36", 24 AWG Thermocouple Wire K Type, Single Ended (3 Amps)
7-409803000-036
Thermocouple, ITA, 24 AWG Thermocouple Wire K Type (3 Amps), Twisted Pair, Single Ended
-
product
PXI/PXIe Battery Simulator Module, 2-Channel, V/I Readback, Simplified Current Sink, 750 V Isolation
43-752A-913
Targeting EV, automotive, aerospace, energy storage and electric aircraft applications, the new battery simulator modules occupy a single PXI slot. These 2-channel battery simulators are capable of supplying up to 7 V and 300 mA per channel. The channels are fully isolated from ground and from each other, allowing series connection to simulate batteries in a stacked architecture.
-
product
4, 8, 16, 32 Channel ARINC429 Test And Simulation Module For PCI
APXX429-x
ARINC429 Test and Simulation bus interface with 4, 8, 16 or 32 Software programmable Tx/Rx channels plus up to 8 Discrete I/O’s.
-
product
PXI/PXIe Battery Simulator Module, 4-Channel, 750 V Isolation
43-752A-002
Targeting EV, automotive, aerospace, energy storage and electric aircraft applications, the new battery simulator modules occupy a single PXI slot. These 4-channel battery simulators are capable of supplying up to 7 V and 300 mA per channel. The channels are fully isolated from ground and from each other, allowing series connection to simulate batteries in a stacked architecture.
-
product
PXI/PXIe Battery Simulator Module, 6-Channel, 750 V Isolation
43-752A-001
Targeting EV, automotive, aerospace, energy storage and electric aircraft applications, the new battery simulator modules occupy a single PXI slot. These 6-channel battery simulators are capable of supplying up to 7 V and 300 mA per channel. The channels are fully isolated from ground and from each other, allowing series connection to simulate batteries in a stacked architecture.