Showing results: 16 - 30 of 33 items found.
-
TOC-VWP -
Shimadzu Corp.
Phosphoric acid and the oxidant (persulfate) are added to the sample, which is heated under UV illumination to convert the TC in the sample to carbon dioxide. This carbon dioxide flows with the carrier gas via the dehumidifier into the NDIR sample cell. The area of the carbon dioxide peak signal is measured and this peak area is converted to TC concentration using a pre-prepared calibration curve.
-
Shimadzu Corp.
Currently, there is a strong demand for the introduction of development, manufacturing and control systems in accordance with GxP at pharmaceutical manufacturing and development sites. And, in pharmaceutical manufacturing, water quality control in line with the GxP guidelines is also required for water used as raw materials and rinsing water. The TOC-V/L Series conforms not only with USP (United States Pharmacopeia) and JP (Japanese Pharmacopeia) but also with other world standards (EPA, ASTM, JIS, ISO, etc.), and demonstrates its outstanding performance in TOC control and cleaning validation of pharmaceutical water.
-
-
eTOC series -
Shimadzu Corp.
Demands for highly purified water and its quality control are getting stronger in many industries, such as pharmaceutical, medical device, food/beverage, chemical, precision machinery, and semiconductor.Shimadzu's eTOC has been designed to satisfy this demand.
-
TOC-L Series -
Shimadzu Corp.
The TOC-L series of TOC analyzers adopts the 680°C combustion catalytic oxidation method, which was developed by Shimadzu and is now used worldwide. While providing an ultra wide range of 4 μg/L to 30,000 mg/L, these analyzers boast a detection limit of 4 μg/L through coordination with NDIR. This is the highest level of detection sensitivity available with the combustion catalytic oxidation method. In addition, the combustion catalytic oxidation method makes it possible to efficiently oxidize not only easily-decomposed, low-molecular-weight organic compounds, but also hard-to-decompose insoluble and macromolecular organic compounds.
-
OI Analytical
Total organic carbon (TOC) measurement is a well-established technique that provides valuable information about water quality for process control and regulatory compliance. Around the world, people have relied on our instrumentation for fast, accurate results for over 45 years. Our Total Organic Carbon (TOC) portfolio includes the 1080 Combustion TOC Analyzer, the 1030W Wet Oxidation TOC Analyzer, and the 1030D Dual Mode Analyzer – all of which are individually designed to help laboratories maximize efficiency.
-
-
Fusion -
Teledyne LABS
Almost 40 years ago, Dohrmann began designing and manufacturing premier Total Organic Carbon (TOC) Analyzers. Since joining the Tekmar family, the tradition of producing innovative laboratory TOC analyzers continues. The Dohrmann Series Fusion Total Organic Carbon Analyzer is no exception. The Fusion TOC Analyzer offers more flexibility, intelligence and user friendliness making this analyzer ideally suited for the most demanding laboratory needs.
-
Shimadzu Corp.
The TOC-Control L/V is PC control software provided with the TOC PC control modules. This software features excellent operability, provides a wealth of functions, and enhances analysis operations.
-
HT-110 -
HORIBA, Ltd.
The continuous online TOC-Analyzer HT-110 is suitable for the measurement ot total organic carbons in Purified Water (PW), Water For Injection (WFI) and Highly Purified Water (HPW). The unit is operating according to USP 643. It is applicable for pharmaceutical and/or semiconductor manufacturing. The measuring principle is based on UV-Oxidation and measurement of the difference in conductivity. TOC concentration measurement (TOC concentration 500 ppbC or lower) is necessary to perform quality control according to GMP (Good Manufacturing Practice).
-
TNM-L -
Shimadzu Corp.
Perform simultaneous TOC and TN measurements. *720 °C catalytic thermal decomposition/chemiluminescence methods are adopted for TN measurement. There is no interference from metallic ions or bromine in sea water.*Measurements over a wide range with a detection limit of 5 μg/L for TOC-LCH to an upper limit of 10,000 mg/L.
-
Tile-on-Card™ -
Celadon
Celadon’s uniquely robust and repairable patented probe-in-ceramic crash resistant probe cards reduce maintenance headaches while increasing tester utilization. Celadon’s TOC™ probe cards are known for achieving 10 million+ touch downs before rebuild on test floors worldwide.
-
ASX‑280 -
Teledyne LABS
Users call CETAC Autosamplers the best on the market, and it’s easy to see why. Put the most reliable, efficient and solidly built autosampler to work in your lab for sample analyses. We have a model to meet your needs, regardless the size of your lab or your specific technique, whether AA, ICP, ICP-MS, TOC, US-VIS, flash/prep chromatography, protein purification, liquid handling or others.
-
ASX‑560 -
Teledyne LABS
Users call CETAC Autosamplers the best on the market, and it’s easy to see why. Put the most reliable, efficient and solidly built autosampler to work in your lab for sample analyses. We have a model to meet your needs, regardless the size of your lab or your specific technique, whether AA, ICP, ICP-MS, TOC, US-VIS, flash/prep chromatography, protein purification, liquid handling or others.
-
TOC-625 MICRO -
International Gas Detectors Ltd
For small systems up to 8 devices with simple I/O requirements this system is ideal. The TOC-625 Micro Gas Detection System Controller interfaces with existing TOC-30A addressable gas detectors and has auto detect and set up features making deployment fast and easy for installers not used to gas detection systems.