Filter Results By:

Products

Applications

Manufacturers

Switches

enable on off function or change of direction.

See Also: Membrane Switch, Coaxial Switches, Crossbar, High Voltage Switching, Fiber Optic Switching, Microwave Switching, Optical Switch


Showing results: 1366 - 1380 of 1524 items found.

  • PXI MUX 2 Banks of 64 Channel 1 Pole

    40-610-022-2/64/1 - Pickering Interfaces Ltd.

    This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer

  • PXI MUX 8 Banks of 16 Channel 1 Pole

    40-610-022-8/16/1 - Pickering Interfaces Ltd.

    This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer

  • PXI MUX 1 Bank of 128 Channel 1 Pole

    40-610-022-1/128/1 - Pickering Interfaces Ltd.

    This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer

  • PXI MUX 4 Bank 0f 16 Channel 1 Pole

    40-610-021-4/16/1 - Pickering Interfaces Ltd.

    This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer

  • PXI MUX 2 Bank, 32 Channel Screened 1 Pole

    40-610-021-S-2/32/1 - Pickering Interfaces Ltd.

    This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer

  • PXI MUX 1 Bank, 64 Channel Screened 1 Pole

    40-610-021-S-1/64/1 - Pickering Interfaces Ltd.

    This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer

  • PXI MUX 2 Banks of 32 Channel 2 Pole

    40-610-022-2/32/2 - Pickering Interfaces Ltd.

    This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer

  • PXI MUX 1 Bank of 64 Channel 1 Pole

    40-610-021-1/64/1 - Pickering Interfaces Ltd.

    This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer

  • Triple Alarm CAT IV Non-Contact Voltage Detector with Flashlight

    FLIR VP50-2 - Teledyne FLIR

    The FLIR VP50-2 is a durable, CAT IV-rated non-contact voltage detector featuring light, vibration, and beeper feedback alarms and a powerful LED flashlight. Use the VP50-2 to reliably check if an AC circuit is live before beginning work; detect voltage on exposed conducting parts or through insulation; identify live wires within electrical panels, switches, and outlets; or trace live wires and map circuits. With an ergonomic and drop-tested design, the FLIR VP50-2 is the right choice for professionals performing field troubleshooting and verification of electrical installations within residential, commercial, and industrial buildings.

  • PXI 24 x DPST Reed Relays

    40-115-122 - Pickering Interfaces Ltd.

    Available in normally open (DPST & SPST) configurations. Connections are made via a front panel micro-D 96-pin male connector. For applications requiring improved bandwidth and crosstalk performance please look at our 40-120 and 40-125 range of shielded reed relay cards. General purpose reed relays are suitable for the construction of small switching networks, slaving up to larger switches or operating external devices (e.g. lamps, solenoids etc.). To simplify inter-relay wiring, interconnection points are built onto the circuit board easing the construction of complicated wiring.

  • 3U CPCI-S.0 Blades

    ADLINK Technology Inc.

    The PICMG CPCI-S.0 CompactPCI Serial standard, which evolved from the PICMG 2.0 specification, is the fastest, most versatile, most cost-effective open standard for CompactPCI (CPCI). The Serial standard is mechanically and electronically compatible with 3U and 6U euro-cards, defining an interface for high-speed switched fabrics with a star topology. Point-to-point connectors allow up to eight peripherals on one system slot without switches or bridges. Ethernet data transfer can be configured with full mesh topology, which allows up to 1000Base-T connections to all peripheral slots for redundant, safety-critical systems.

  • PXI Single 6-Channel 30A Solid State MUX

    40-667-012 - Pickering Interfaces Ltd.

    The 40-667 is a high current multiplexer available in dual 3-channel or single 6-channel configurations occupying two slots of PXI chassis. Each multiplexer switch uses a fully isolated solid state relay which has been designed to offer fast operation under hot switching conditions and high inrush current with no operational life degradation. Each multiplexer channel can support 30A of continuous current and switch up to 40V signals. The switches can sustain inrush currents in excess of 120A. AC or DC signals can be switched since the switch is polarity insensitive.

  • PXI Triple 4 to 1 RF Multiplexer 6GHz 50 Ohm SMA Terminated

    40-882-003 - Pickering Interfaces Ltd.

    A 50 Ohm 4 to 1 6GHz PXI RF multiplexer available as a single MUX in one PXI slot, a dual MUX in two PXI slots, or triple and quad MUXs in three slot PXI modules. This PXI multiplexer exhibits low VSWR characteristically over the full operating frequency range and consistent insertion loss characteristics. The use of solid state switches ensures a long service life with no wear out mechanism, making the 40-882 MUX ideal for ATE systems requiring frequent and fast operating RF switching.

  • PXI 16 x SPST Reed Relay

    40-115-021 - Pickering Interfaces Ltd.

    Available in normally open (DPST & SPST) configurations. Connections are made via a front panel micro-D 96-pin male connector. For applications requiring improved bandwidth and crosstalk performance please look at our 40-120 and 40-125 range of shielded reed relay cards. General purpose reed relays are suitable for the construction of small switching networks, slaving up to larger switches or operating external devices (e.g. lamps, solenoids etc.). To simplify inter-relay wiring, interconnection points are built onto the circuit board easing the construction of complicated wiring.

  • PXI Quad 4 to 1 RF Miltiplexer 6GHz 50 Ohm SMA Terminated

    40-882-004 - Pickering Interfaces Ltd.

    A 50 Ohm 4 to 1 6GHz PXI RF multiplexer available as a single MUX in one PXI slot, a dual MUX in two PXI slots, or triple and quad MUXs in three slot PXI modules. This PXI multiplexer exhibits low VSWR characteristically over the full operating frequency range and consistent insertion loss characteristics. The use of solid state switches ensures a long service life with no wear out mechanism, making the 40-882 MUX ideal for ATE systems requiring frequent and fast operating RF switching.

Get Help