Showing results: 106 - 120 of 175 items found.
-
DRTS 64 -
Altanova Group
DRTS 64 is the most powerful diagnostic test set designed to perform accurate tests on protection relays, transducers, energy and power quality meters. This advanced test equipment is also thought to satisfy all the needs related to commissioning and substation maintenance. 6 Current and 4 Voltage generators simultaneously available.
-
R.R.Transformers & Equipments
High Voltage Breakdown Testers also known as Hipot Testers or Insulation Testers are a necessity for any Transformer testing, Substation equipment testing, Cable testing, Panel testing and testing of various insulating materials. Insulation testing is very important to ensure and maintain the safety of electrical equipments and also for the safety of operator.
-
Arbiter Systems, Inc.
Arbiter Systems®, Inc. delivers world class GPS based precision timing and frequency solutions for a variety of evolving markets. Engineered and manufactured in the USA, Arbiter precision time clocks and supporting products surpass industry standards in terms of accuracy, flexibility, reliability, connectivity and value, and are as at home in the substation as they are in the laboratory.
-
R.R.Transformers & Equipments
High Voltage Breakdown Testers also known as Hipot Testers or Insulation Testers are a necessity for any Transformer testing, Substation equipment testing, Cable testing, Panel testing and testing of various insulating materials. Insulation testing is very important to ensure and maintain the safety of electrical equipments and also for the safety of operator.
-
UPS S3 -
Manta Test Systems
The Vanguard UPS S3 is an AC/DC adjustable output power supply designed to operate substation circuit breakers. The UPS S3’s AC and DC voltage sources can supply up to 10 Amperes during the circuit breaker coil energization and circuit breaker charging motor operation. Powered by a single phase 90-120 Vac voltage source, the UPS S3 provides an isolated adjustable AC/DC voltage source. Output voltages are variable via the front panel control knob.
-
SA10A -
Elcon International AB
It has a built-in micro Ohm meter/Ductor for measuring of static and dynamic resistance of the breaker poles. It only weighs 11,6 kg. The versatility and precision that this unit offers is, without question unchallenged, and it will indeed be your best partner when testing circuit breakers. Tests in areas with high induction at known problematic substations has proven the SA10A to be the only circuit breaker timer that could withstand these extreme conditions. It's rugged, it's small and highly appreciated by our customers.
-
PDS200 -
Doble Engineering
The Doble PDS200 is a combination survey tool that uses radio frequency interference and electromagnetic interference diagnostics to find signs of partial discharge.This hand-held instrument is an ideal tool for a condition based maintenance program, allowing you to quickly find insulation defects in motors, generators, transformers, cable terminations and additional substation components.
-
EPM 2200 -
GE Digital Energy
The EPM 2200 meter measures more than 40 electrical power parameters providing a low-cost, multifunction monitoring solution for industrial and power generation applications. EPM 2200 can easily be mounted in a panel for generator monitoring, substation automation and more. The meter can also provide data to RTUs, PLCs and other control devices.
-
CableTroll -
Nortroll
They are installed on Ring Main Units in distribution substations. They are used to detect short circuit and earth faults, and can be installed on most types of cable terminations. Some units will give separate indications for short circuit and earth faults, locally by flashing diodes and remotely through separate relay contacts or additional ComTroll communications modules.
-
EPM 9800 -
GE Digital Energy
With the socket type mount design EPM 9800 meter is perfect for industrial and utility substation automation applications where both power quality monitoring and revenue accuracy are required. EPM 9800 provides most accurate analysis of electric power and energy. Using advanced DSP technology meter measures instant and stored revenue power data.
-
MT-3551T -
Kongter Test & Measurement Co., Limited
It is multi-functional in field testing for power meters and metering units of all wirings. Testing functions include: metering unit and power meter. With these function, it is widely used in power utility, substation, telecom machine room and the alike for power consumption examination, circuit breakage inspection, power abnormality analyzing, asset management and industrial production management.
-
TransData, Inc.
Manufactured for utilities since 1969, TransData Power Transducers are used for measuring AC and DC power variables in Substation, Generation, Load Control and Industrial applications where ±1ma or 4-20mA analog signal are required by the SCADA/Energy Management System. Models are available for measuring Current, AC Voltage, DC Battery Voltage, Watts, VARs, Frequency and more.
-
TAURUS PRECIOHM ET -
Taurus Powertronics Systems
The TAURUS PRECIOHM ET is one of the specially designed products by TAURUS to measure earth resistivity and earth resistance in a power station. These tests are performed based on 4 point (Wenner) and 3 point (fall of potential) methods respectively. All electrical equipment in the substation and power stations are electrically connected to station earth mat with earth electrodes. The earth electrode ensures that in the event over voltage on the system due to system fault or lighting discharges etc., the parts of the equipment which are normally ”dead” as far as voltages are concerned; do not attain dangerously high potentials. An earth electrode will only be effective so long it has a low resistance to the earth and can carry large currents without deteriorating. Thus the resistance of earth electrode should be low to give good protection and it must be continuously measured and monitored in all the substations and power stations.
-
Megger Group Ltd.
Primary current injection testing is utilised in high current/high voltage scenarios found at large electrical installations such as substations. A large current (between 100A and 20,000A depending on system specifications and test requirements) is injected directly on the primary side of the electrical system such as a circuit breaker. The objective of the test is to identify how the system operates under various levels of current load.
-
SHERLOG -
KoCoS Messtechnik AG
Fault recorder systems with a power quality analyser for comprehensively monitoring and assessing low, medium and high voltage networks in power plants and transformer substations. The measuring devices of the SHERLOG range make very high-resolution recordings of all the disturbances which occur in power supply systems. The behaviour of protection and switchgear devices during these system disturbances is recorded at the same time.