  • Enlarge Environmental Chamber

    REXMED REC-480 - REXMED Industries Co., Ltd.

    MOD. REC-480, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -40˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 2.3KW X 2pcs, Humidity heater: 4.5KW X 1pc, Heat up transition time: -40˚C~100˚C within 45 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 5,270 Watts, 18,000 BTU/hr, 4,545 Kcal/hr, Cool down transition time: 20˚C~-40˚C within 50 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L100 X W80 X H100cm, Capacity: 800L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • Environmental Chamber

    REXMED REC-200 - REXMED Industries Co., Ltd.

    MOD. REC-200, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -20˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 1.5KW X 2pcs, Humidity heater: 2.5KW X 1pc, Heat up transition time: -20˚C~100˚C within 35 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 1,892 Watts, 6,455 BTU/hr, 1,630 Kcal/hr, Cool down transition time: 20˚C~-20˚C within 45 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L50 X W60 X H75cm, Capacity: 225L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • 4 Digit Temperature Meter (5 Channels)

    CM1-TX5 - Chuan Sheng Electronics Co., Ltd.

    RS-485 Modbus RTU protocol (with communication LED indicator)RS-485 address 1~255Communication Baudrate 9600, 19200, 38400, 57600, 115.2KParity check N81, N82, E81, O81Input 5 channels of signal selectable:thermocouple/PT100.5 channels of input can be set to play 1~10 seconds loop display.1~5 channels of display value limits can be set, and the number of channels of carousel display screens can be set by yourself.5 channels of input signals with LED unit cycle display.Standard 2 groups of alarms Hi, LO with communication LED indicators to ensure the normal operation of the field system.Suitable for HVAC refrigeration and air conditioning PLC, DDC, PC brands to achieve remote real-time monitoringCan be used in solar panels, medical control, clean room, ice water host, boiler, motor, chemical plant, power plant, school energy-saving control, remote control of power monitoring panel

  • Environmental Chambers

    KB Series - Darwin Chambers Company

    Darwin Chambers KB series Environmental Chambers are a top selling unit. It is quiet, easy to clean, highly reliable and ideal for laboratory use. Our environmental chamber offers hot gas bypass control of refrigeration and resistive heat to facilitate reliable, critical temperature and humidity control. All KB series environmental testing chamber models are designed to have a temperature range of 4-60o Celsius. Temperatures greater than 60o Celsius or lower than 4o Celsius can be achieved with optional upgrades to construction and components. All KB series environmental chambers come standard with Fuji’s PXG4 microprocessor, but we often install Watlow brand microprocessors for customers that need that brand or the capabilities it has. Unlike many proprietary controllers on the market, these controllers are available off the shelf and have been proven in tens of thousands of installations. All necessary functions are included in our Features section below. Many additional options are available both regarding control and recording of data (chart recorders and loggers)

  • High and Low Temperature Humidity Chamber

    GDJS/GDJW - Lisun Electronics Inc.

    •The chamber is produced by SUS304 Steel, the temperature keeping material is produced by Polyurethane hard foam and ultra-fine fibre glass, the doorframe heat insulated by Double high temperature aging silicone rubber door sealing strip. •The temperature controller is used by Korean TEMI display in English/Chinese and German Siemens PLC, it can be communicated to PC via RS-232. The temperature accuracy is 0.1℃ and humidity is 0.1%R.H •The temperature sensor is platinum PT100 Ohms/MV resistor •The heating system is full separately system which produced by Nickel chromium alloy electric heating type heater •The cold system is applied by fully enclosed fan cooled single-stage and cascade refrigeration mode, the compressor is from France TECUMSEH brand which can allow you get after sales support from many countries •The cyclical system is applied by High temperature low noise air conditioning type motor and Multi blade centrifugal wind wheel •The safety self-protection function include Electric leakage, short circuit, over temperature, motor overheating, compressor pressure, overload, over-current protection •Working Power: AC380V±10% 3phases and frequency 50Hz/60Hz •Working Environmental: Temperature is 5℃~+30℃  Humidity ≤85%R.H