Showing results: 16 - 30 of 52 items found.
-
Synopsys, Inc.
Synopsys TIS Pro is an optical scattering instrument for efficient measurements of reflectance, transmittance and absorption. This fully automated device features an integrated sphere and a spectral detector assembled in a housing that controls stray light to ensure fast, accurate measurement results.
-
SHSCAD -
Physical Sciences Inc.
Wide area, high areal coverage rate surface contaminant detection via LWIR reflectance spectroscopy employing eye safe broadband quantum cascade lasers (QCLs) and a high-speed spatial heterodyne spectrometer (SHS) in a handheld sensor package (~ 10,000 cm3, 10 lb).
-
LINZA 150 -
EssentOptics Ltd.
LINZA 150 spectrophotometer is designed for broadband transmittance and reflectance measurement of lenses and lens assemblies (objectives) ensuring that only perfect lenses are approved for lens assemblies, delivered to customers or meet specs provided to your lens supplier. The instrument is perfectly suited for both routine lens measurements and sophisticated improvement of lens production technology: Fast on-axis transmittance measurement of individual convex/concave lenses. Fast on-axis transmittance measurement of lens assemblies (objectives). Unattended on-axis and off-axis reflectance measurement of individual lenses providing measurement data virtually from any area on lens surface (both convex and concave). Ideal for fine-tuning of deposition technology used to produce coatings on lenses.
-
TP140B Report Printer -
RJS Technologies, Inc.
The TP140B Report printer allows for printing of inspection reports from your Inspector series bar code verifier. The printer provides a simple report that will have a line for each bar code inspected. Note: The Verifier Computer Interface Report (VCIR) is required if you need the Scan Reflectance Profile (SRP).
-
PIMACS CO., LTD.
The visibility is an important factor for road markings, traffic signs, road studs as well as high-visibility material such as warning clothes and Heavy good vehicles (HGV's) contour safety marking.The measurement of retroreflectivity is essentially a measurement of the reflectance of material under specified geometrical and spectral conditions. Instruments are available for measuring the retroreflectivity of various reflection materials.
-
10772A -
Keysight Technologies
The Keysight 10772A Turning Mirror is a 100% reflectance mirror that turns the direction of an incoming laser beam 90 degrees. The mirror is used in the 5530 Laser Calibration System for applications such as machine tool calibration. It can be used in place of the 10707A Beam Bender (6 mm or less beam diameter) for applications that require the larger aperture of the 10772A.
-
FieldSpec 4 Standard-Res -
Analytical Spectral Devices, Inc.
The FieldSpec 4 Standard-Res portable spectroradiometer is the right choice for a wide range of remote sensing applications, including multispectral sensor ground truthing and calibration, agricultural analysis, and snow and ice studies. In addition to being a world class spectroradiometer, the FieldSpec 4 Standard-Res is equally suited to serve as a rugged, portable spectrometer for accurate contact reflectance
-
LittleFoot Series -
n&k Technology, Inc.
The n&k LittleFoot-CD, and LittleFoot-CD450 are DUV-Vis-NIR scatterometers/thin film metrology systems, based on polarized reflectance measurements (Rs and Rp) from 190nm to 1000nm, with microspot technology. The systems in the LittleFoot-CD Series determine thickness, n and k spectra from 190nm-1000nm of thin films, as well as depths, CDs, and profiles of trenches and contact holes.
-
HandHeld 2 Pro -
Analytical Spectral Devices, Inc.
The FieldSpec HandHeld 2 Pro hand-held spectroradiometer offers greater sensitivity over the standard HandHeld 2 spectroradiometer model, aiding spectral measurements for applications with low reflectance characteristics such as water surfaces. Wherever there is a need for enhanced sensitivity, faster collection rates, high signal to noise performance, the HandHeld 2 Pro is the low cost VNIR spectroradiometer of choice.
-
SP-80 -
Lumetronics
Integrating Spheres are essential tools for photometric research laboratories & lamp / luminaire manufacturers. A good internal coating is essential forintegrating spheres. It is a special water based BariumSulphate (BaSO ) white reflective paint particularly suitablefor internal coating of Integrating Spheres. It offers an almost constant reflectance in the range of 380 nm to 780 nm (visible wavelength range).
-
USB-650 -
Ocean Optics, Inc.
USB-650 Red Tide spectrometers are ideal for teaching about UV and visible absorbance, reflectance and emission applications. They are preconfigured, ready-to-use spectrometers that come in several different options. Fully integrated – USB650-UV-VIS and USB650-VIS-NIR models are preconfigured, ready-to-use systems.
-
OptoTest Corp.
Optical Reflectance Scan Mode, Programmable Pass/Fail Criteria for on-screen test results, and On-Screen Context Help. Additionally, it can measure return loss at two positions simultaneously through the front panel meaning that it can test the RL of both connectors on a patch cord without the need for software. As with OptoTest’s other return loss systems, the tests are performed without the need for mandrel wrapping or index matching gel.
-
Luzchem Research Inc.
This system that makes complex electronics, cumbersome software and large optical benches a thing of the past. The LFP system incorporates everything needed except the excitation laser. This is a simple, yet powerful instrument, ready to perform a wide range of time resolved kinetic and spectroscopic measurements involving transient absorption or diffuse reflectance. The LFP system, including the monochromator and digitizer is completely computer controlled, making it easy to obtain
-
ZOLIX
Xe arc lamp light sources are the preferred artificial sources to simulate sunlight. The high color temperature (6000K) of the Xenon lamps is a close match to the solar temperature. This results in very similar solar spectra in the UV and VIS although the source has some Xe emissions lines in the near IR. Application for fluorescence, luminescence and phosphorescence, absorbance and reflectance, photochemistry, photolithography, solar simulation and so on.ct description goes here.
-
TCi -
C-Therm Technologies Ltd.
The default C-Therm TCi Thermal Conductivity Analyzer employs the Modified Transient Plane Source (MTPS) technique in characterizing the thermal conductivity and effusivity of materials. It employs a one-sided, interfacial heat reflectance sensor that applies a momentary constant heat source to the sample. Typically, the measurement pulse is between 1 to 3 seconds. Thermal conductivity and effusivity are measured directly, providing a detailed overview of the heat transfer properties of the sample material.