Filter Results By:

Products

Applications

Manufacturers

RS422

One of several standards that incorporate balanced line signals into DB connectors. A pair of wires is used to carry each signal. The data is encoded and decoded as a differential voltage between the two lines. (www.sangoma.com)

See Also: Serial Communications, I2C, RS232, RS485


Showing results: 196 - 202 of 202 items found.

  • Physical Layer Switching Systems for copper LAN, WAN, DSL, Telco apps with RJ style connectors.

    RJ Series - Cytec Corp.

    The RJ Series of computer controlled switching systems are designed for physical layer switching of multiwire signals on RJ style connectors. Since the system uses mechanical relays it acts exactly like a piece of cable which makes it perfect for testing networks without altering the signals or regeneration. These systems are typically used for Ethernet LAN 10BaseT through 1000BaseT, DSL including ASML through GFAST, CAT5 through CAT6A cable testing, USB up to 2.0, RS232, RS422, RS485 up to 8 wire at 20 Mbps and many other applications switched over RJ45 connectors up to 8 wires. They may also be used as lab automation switches, network testing switches, patch panels, network redundancy switches or any number of physical layer applications.

  • Physical Layer Switching Systems for Copper LAN, WAN< DSL, Telco Apps with RJ Style Connectors

    RJ Series Switching Systems - Cytec Corp.

    The RJ Series of computer controlled switching systems are designed for physical layer switching of multiwire signals on RJ style connectors. Since the system uses mechanical relays it acts exactly like a piece of cable which makes it perfect for testing networks without altering the signals or regeneration. These systems are typically used for Ethernet LAN 10BaseT through 1000BaseT, DSL including ASML through GFAST, CAT5 through CAT6A cable testing, USB up to 2.0, RS232, RS422, RS485 up to 8 wire at 20 Mbps and many other applications switched over RJ45 connectors up to 8 wires. They may also be used as lab automation switches, network testing switches, patch panels, network redundancy switches or any number of physical layer applications.

  • Protocol Converter

    MACC2 - Excalibur Systems, Inc.

    When designing or upgrading avionics systems we are often faced with the task of integrating components that were not originally designed to work together.A control computer that communicates using RS-232 may need to control component that expects MIL-STD-1553 messages or an INS may put out ARINC-429 labels, which are needed by Multi function Display designed around RS-422.Faced with problems like these, integrators must choose between two poor options. They must either give up on one of the units in favor of another unit that may be less suitable but uses the appropriate communications spec; or they must add a computer system – often PC104 – which can translate from one unit to the other. These computers are generally large, heavy, hot, and require substantial power.

  • Protocol Converter

    MACC - Excalibur Systems, Inc.

    When designing or upgrading avionics systems we are often faced with the task of integrating components that were not originally designed to work together.A control computer that communicates using RS-232 may need to control component that expects MIL-STD-1553 messages or an INS may put out ARINC-429 labels, which are needed by Multi function Display designed around RS-422.Faced with problems like these, integrators must choose between two poor options. They must either give up on one of the units in favor of another unit that may be less suitable but uses the appropriate communications spec; or they must add a computer system – often PC104 – which can translate from one unit to the other. These computers are generally large, heavy, hot, and require substantial power.

  • Compact Protocol Analyzer

    LE-1500R - LINEEYE Co., Ltd.

    "LE-1500R" is a protocol analyzer (line monitor) dedicated for asynchronous communication monitoring with affordable pricing. LE-1500R can run as a stand- alone by the internal battery for long time and can be remotely controled by a PC or a smart phone via Wi-Fi (Wi-Fi function is available only in USA, Canada, Japan, and EU). The analyzer has a TTL measurement port (which supports UART communication) as its standard port besides RS-232C, RS-422, and RS-485. It can monitor communication data of max 500Kbps for up to 32MB (8,000,000 data) in real time and also can execute a simulation testing of send/receive data. It also has a BERT function (which is not equipped with the analyzers of this pricing level) as its standard function. The correct time stamp, the measurement of idel time (which are the difficult for other software analyzers), and the capturing ability (without missing data) are the best options for trouble shooting and development test of a communication sytem which requires a reliablity.

  • Long-range Surveillance Thermal Imaging Camera

    IRT303 - Wuhan JOHO Technology Co., Ltd

    Long-range Surveillance Thermal Imaging Camera IRT303IRT303 is extremely compact, durable uncooled day/night system, operating in 8-14 um waveband, with DDE image processing technology and high sensitivity, it is ideal for quick and accurate situational awareness in a variety of defense and security applications. It specially equipped with Dual-FOV, the wide FOV for find object in wide scope and then fast switch to narrow FOV looking at the target for details. IRT303 is the optimal device for super long observation purpose and target acquisition.ApplicationsLong distance surveillance or patrolLand border and coast surveillanceMarine navigation or rescueTechnical DataDetector Detector material Uncooled FPA Spectral range 8~14 m Pixels 320x240 Pitch 38 mx38 m NETD 50mK@25 C (f/0.7) Optics Lens 135mm/45mm FOV 5.2 3.9 /15.4 11.6 Focusing Motorized Optional lens 100mm/25mm, 120mm/40mm, 150mm/50mm, 180mm/60mm Image Presentation Video output 25Hz PAL/30Hz NTSC Electronic Zoom x2 Polarity BH/WH inverse Brightness & Contrast Auto/ Manual Gain Composition Auto/ Manual Power system Power supply 110~240VAC 9~14VDC (typical: 12VDC) Interfaces Command interface RS232 /RS485/ RS422 alternative Digital video interface(Optional ) Ethernet/LVDS/CameraLink Environmental Ambient temperature -40 C~+60 C Storage temperature -45 C~+60 C Range Performance Detection Range (2.3mx2.3m vehicle) 5500m Recognition Range (2.3mx2.3m vehiclet) 1800m Detection Range (1.8mx0.5m human) 2200m Recognition Range (1.8x0.5m human) 580m

  • Multiprotocol P104Plus Interface Board for Embedded Applications or Avionics Test & Simulation Applications

    EXC-4000P104plus - Excalibur Systems, Inc.

    The EXC-4000P104plus is a multiprotocol P104plus interface board for embedded applications or avionics test and simulation applications. Each board holds up to five independent modules. Two on-board modules use the MIL-STD-1553 communications protocol (M4K1553Px); another on-board module uses the ARINC-429 communications protocol; two additional detachable modules can be any one of the following types:M4K1553PxS (Single Function - RT validated) This module operates as a Bus Controller, Remote Terminal or a Bus Monitor. This module qualifies for airborne applications.M4K1553Px (Multi Function) This module operates as a Bus Controller, up to 32 Remote Terminals and as a Bus Monitor. Supports an Internal Concurrent Monitor in RT and BC/RT modes.M4K1553Px(S)-1760 Same as M4K1553Px(S) plus MIL-STD-1760 options.M4KMMSI Mini Munitions Store Interface module. Supports RT, BC/Concurrent-RT/Concurrent Monitor and Bus Monitor modes. Up to 8 hub ports EBR-1553 [10 Mbps 1553 protocol using RS-485 transceivers] and 1 monitor output.M4KH009 Based on our H009 family. This module operates as a Central Computer Complex (CCC) and/or up to 16 Peripheral Units (PUs) simultaneously, or as a Bus Monitor. In addition, a Concurrent Bus Monitor enables concurrent monitoring of the bus during CCC and PU simulation.M4K429RTx Based on our ARINC 429RxTx board. This module supports either five or ten ARINC 429 channels each of which can be configured in real time as a receive or transmit channel.M4K708 This module supports two channels of ARINC 708/453, each one selectable as either transmit or receive.M4KSerial This module supports up to 4 independent channels of serial communications, each of which can be selected as RS485, RS422 or RS232.M4KDiscrete This module supports 20 selectable input/open collector output discretes. The module supports TTL (0 to 5 volts) or avionics (0 to 32 volts) voltage levels.M4KCAN This module supports up to 6 independent channels of CAN 2.0B protocol with standard and extended message frames and message identifiers.

Get Help