Showing results: 31 - 45 of 51 items found.
-
Multifunction Loop Tester -
MEET International Ltd.
*Measure AC / DC Voltage upto 750V (AC) / 1000V (DC)*Measure resistor, diode, capacitor*Continuity check*Non Contact Detector NCD (ACV)*Single Probe Test, identify Live / Neutral (SPT)*Measure Frequency and Duty cycle*Socket test*RCD test*Loop test
-
MPI-502 -
Sonel S.A.
Short circuit loop parameters measurements:measurements of short circuit loop impedance in networks with rated voltage: 220/380 V, *230 V/400 V, 240/415 V and frequency 45...65 Hz,*measurements of short circuit loop impedance with current 15 mA without tripping the circuit breaker.Testing the RCD breakers of AC, A types:*testing of prompt, short-delay (general) and selective RCDs for the rated current values 10, 30, 100, 300, 500 mA,*IA measurement*RE and UB measurement without tripping the circuit breaker,*extended RCD test function AUTO, with measurement of ZL-PE with current 15 mA - measurement of IA and tA during one RCD tripping.Detection of the replacement L and N in the socket and automatic conversion in the meter.Low voltage resistance measurements of protective circuits and junctions:*measurement of resistance with ±200 mA current*calibration of test leads - possibility of using any length of test leads,*low current resistance measurement with accoustic signalling
-
CZ20500 -
Aegis Pty. Ltd.
The CZ20500 Multi-Function electrical tester includes some of the latest advances in electrical testing, combining 5 instruments into 1! Insulation, Loop, Phase, RCD, and Voltage testing are all included in the one instrument, making your job of installation testing easier.
-
ETAP Enterprise
60364-4-41 StandardBS 7671 StandardEN 50122 StandardTN-C, TN-S, TN-C-S, TT & IT Earthing TypesElectric shock requirementsLoop impedance and current calculationTouch voltage calculation and evaluationCalculation considers resistance to ground / earthGround Fault Current Interrupter (GFCI) or Residual Current Circuit Breaker (RCCB) or Residual Current Detector (RCD) protectionReports in Crystal Reports and MS Excel
-
1662 -
Fluke Corporation
The Fluke 1662 installation tester gives you Fluke reliability and all the basic testing power you need for day-in, day-out installation testing. It tests to all local regulations and is easy and intuitive to use. Additional helpful features like the On/Off switchable auto-start for RCD and loop test, and self-test save time and give you more confidence in your results.
-
1945 -
Peaceful Thriving Enterprise Co Ltd
This is a portable 220VAC socket tester to inspect the wiring conditions. The tester also features current variation for simulation of different leaking current. With the current variation, technician is able to test the condition of Ground Fault Circuit Interrupter (GFCI) / Residual Current Device (RCD) easily.
-
PAT-815 -
Sonel S.A.
TECHNICAL SPECIFICATIONFILESPAT-815 digital meter is used to measure the parameters of electrical equipment (power tools, white goods, etc.) which determine their safety: resistance of protective conductors, insulation resistance, continuity of connections, leakage current, power, automatic measurement of all RCD parameters.
-
Di-Log
Our range of CombiVolt voltage testers are designed to measure AC/DC voltages and continuity. Most models provide LED indication, an audible tone or a combination of both while others have a digital display to give an exact reading, all testers have a non RCD Trip feature
-
PAT-820 -
Sonel S.A.
PAT-820 digital meter is used to measure the parameters of electrical equipment (power tools, white goods, etc.) which determine their safety: resistance of protective conductors, insulation resistance, continuity of connections, leakage current, power, automatic measurement of all RCD parameters. Meter allows fash test/high voltage test.
-
Beha-Amprobe
Offers two models that verify the safety of electrical installations in residential, commercial and industrial applications. Has been developed to carry out the following safety measurements of electrical installations in accordance with EN 61557 and DIN VDE 0100: Insulation resistance, RCD tests, Low Ohm resistance, Earth ground resistance, Loop impedance, Phase sequence.
-
6280 TB -
Standard Electric Works Co., Ltd
● Wide range of operating voltage from AC 210V/50Hz to 250V/50Hz.● For checking AC voltage.● For checking a RCD tester's test current & time in mA(ms).● For checking a loop tester.● For wiring check (Phase, Neutral, Earth).● For checking continuity.● For checking insulation (The maximum is 1.2kV).● For checking UK16th edition.● Safety standard: EN 61010-1 / EN 61326-1
-
DL6780 -
Di-Log
Testing of AC/ DC voltages from 12 to 690 V AC/DC Continuity testing with optical and acoustic indication Automatic switching between voltage and continuity Phase rotation test system Single pole phase indication Fully compliant with GS38 Fully operational voltage indication even when batteries are discharged Will not trip any RCD when testing across Live and Earth Single pole detection when L2 probe connected above 100V
-
Testboy GmbH
Using the new Testavit Schuki 1 LCD and 3 LCD, specialists easily check to see if sockets, cable drums or connecting cables are correctly connected in 230 V installations. Due to three LEDs, the connection status can be quickly and clearly determined. In addition, through the finger contact, it can be tested to see whether an impermissible, high contact voltage is applied at the protective earth connection. In addition, using the Testavit Schuki 1 LCD, a 30 mA FI circuit breaker (RCD) can be triggered via a pushbutton.
-
MPI-525 -
Sonel S.A.
Possible measurementsShort-circuit loop measurement:*impedance measurement with 23 A current (44 A phase-to-phase) - short-circuit resistor R=10,*measurement range: 95...440 V, frequency 45...65 Hz,Short-circuit loop measurement with resolution 0,01, in distribution network without tiggering RCD (In30 mA):*automatic calculation of short-circuit, detection of phase voltage and phase-to-phase voltage,*additional UNI-Schuko plug for automatic measurement, AGT adapter for 3 phase network measurement.Testing of general and selective RCD with the rated differential current of 10,30,100,300,500 and 1000 mA. (Type AC, A and B).Measurement of insulation resistance:*with test voltage 250 V, 500 V, 1000 V, 2500 V,*measurement range up to 10G,*automatic discharging after measurement,*automatic measurement of all resistences in 3,4,5-wire cables using optional adapter AUTO-ISO,*acoustic signals in 5 sec intervals for insulation resistance characteristic,*elapsing T1, T2, T3 times (0...600 s) form measurement of absorption coefficients (DAR, PI or Ab1, Ab2)*safety measurement - protection against overvoltage.Measurement of earthing resistance.Bi-directional testing of PE wire continuity using 200 mA current.*Autocalibration of test leads.
-
3122 -
Metrel d.d.
The MI 3122 SMARTEC Z Line-Loop / RCD is designed specifically for live circuit testing. The instrument contains integrated characteristics of fuses and RCDs for the evaluation of test results. The online voltage monitoring system allows the operator to control what is happening on three simultaneous voltages in real-time. The bright red and green PASS / FAIL lights and help screens for each measurement make the handling of the instrument easy and clear. All the results can be quickly saved on the instrument and then downloaded via the optional A 1291 EuroLink PRO or A 1290 EuroLink PRO Plus software for evaluation and professional report generation after testing.