Showing results: 496 - 510 of 1196 items found.
-
VX Instruments GmbH
Up to 4 potential-free channels, U/I measurement unitsMax. 400 V or 100 A per channelTotal output max. 800 W (10 kW in pulse mode)Integrated switching matrix with self-testStandard: 19", 3/6 U
-
Berkeley Nucleonics Corporation
is a bin and power supply combination for plug-in modules. It can house twelve single-width modular instruments or a mixture of other sizes equivalent to twelve singles. Units that can be installed include BNC's modular digital delay generators, trigger pulse amplifiers, pulse generators, programming interfaces and the instruments of other companies that are designed to NIM standards.
-
Orbit Controls AG
Orbit Controls counters and timers are designed for connection to practically all industrial sensors and pulse sources . They can be used as process monitors to display the process variable to be measured or as process controllers for control and monitoring tasks. The devices display and process pulses and frequencies, as well as quadrature signals from incremental and absolute encoded rotary encoders. In addition to information on the display, the devices also generate data and analog outputs and monitor preselected limit values. The process parameters are entered via the keyboard so that the display is calibrated in the required units and the output signals, serial interfaces and limit values are optimized.
-
XO1 -
Yamasaki Optical Technology
FiberPulse OTDRs send pulses down fiber optic networks from one end of the fiber, displaying a trace and reporting all detected events such as splices, connectors, macrobends and fiber ends and breaks. The total fiber length is reported along with name, location, loss and reflectance of detected events. The intuitive keypad design features integrated shortcut keys designed for quickly positioning and analysing events. Another feature of this unit is the Live Optical Signal Detect Function, which tests if the fiber is live before sending the pulse, this can effectively prevent accidental damage to the OTDR and attached communication equipment.
-
MPR6 Series -
Entes Elektronik
Dimensions:96X96kVArh, Max, Min: available (available) % THD I: available (available) % THD V: available (available)Harmonics 1-51.:RS-485:available (available)Digital Input:Digital Output:2AO:0/14-20mA: AO:0/2-10V:Relay:2 Pulse Output: available (available) Hour (RTC): available (available) Memory:1MB Pulse Counter: none (none) Operating Hour: none (none) Alarm: available (available) CT-25: none (none) 110/230 VAC:none (none) 85-265 VAC/DC: available (available) 45-265 VAC/DC: none (none) 10-56 VDC: none (none) Pcs. / Carton:8
-
Salicon Nano Technology
As Rigol's RF first signal source, the DSG3000 series offers standard AM/FM/ØM analog modulation, as well as options for I/Q modulation and I/Q baseband output. The instrument is available with maximum frequencies of either 3 GHz or 6 GHz. Featuring a high signal purity with phase noise measuring <-110dBc/Hz@20kHz (typical) and a wide output range of -130dBm to +13dBm, the DSG3000 RF signal generator has standard pulse modulation with an on/off ratio of up to 80dB, with optional pulse train generator available. The DSG3000 series also has an amplitude accuracy of <0.5dB (typical).
-
Wuntronic GmbH
Premium Data Loggers for temperature, humidity, co2, atm. Pressure, voltage, current, pulse and 2-state inputs.
-
MOPA -
Fibotec Fiberoptics GmbH
These light sources are compact Master Oscillator Power Amplifier (MOPA) assemblies that can be directly modulated in a fixed range of repetitive frequency and pulse power. The standard products operate in the wavelength range around 1.5 μm at a repetition frequency> 6 kHz and with a pulse energy of 10 μJ / 50 ns (200 W peak power).
-
ifm efector, inc.
*Inputs for analog, digital, diagnostic and pulse signals*Digital, PWM or current-controlled outputs*Programmable to IEC 61131-3 with CODESYS*High-performance CAN interface for various communication tasks*E1 type approval (German Federal Motor Transport Authority)
-
AXC7585 -
VX Instruments GmbH
Generate extremely short, fully regulated current pulses from 300 µs up to 1600 A. At the same time, carry out measurements directly on the DUT with the integrated VMU and CMU. Perfect for rapid semiconductor tests during production.
-
AXC757x -
VX Instruments GmbH
Generate extremely short, fully regulated current pulses from 300 µs up to 250 A. At the same time, carry out measurements directly on the DUT with the integrated VMU and CMU. Perfect for rapid semiconductor tests during production.
-
AXC755x -
VX Instruments GmbH
Generate extremely short, fully regulated current pulses from 300 µs up to 500 A. At the same time, carry out measurements directly on the DUT with the integrated VMU and CMU. Perfect for rapid semiconductor tests during production.
-
Newport Electronics
High speed fiber-optic detectors use special photodiodes with high speed electronic circuits to convert fast pulses in optical fibers to electrical signals for measurement. Unlike our optical receivers, these photodetectors do not include a transimpedance amplifier.
-
DIM-570 -
Tecpel Co., Ltd.
Measure insulation resistance up to 2000M£[. 1000V pulse to test insulation. 3 1/2 Digit LCD Back light display. Auto data hold function after releasing MEAS button. Auto power off function
-
TIO-10 #1 -
VI Control Systems Ltd.
Interface board for converting signals on a National Instruments PC-TIO-10 timing board to and from fiber optic signals. Bursts, delayed pulses, and frequencies can be generated on outputs. The input channel can be used to measure frequency or period.