Filter Results By:

Products

Applications

Manufacturers

Showing results: 346 - 360 of 362 items found.

  • Universal Multichannel System up to 8 kV

    CAEN S.p.A.

    - From 12 to 24 independently controllable High Voltage channels- 8 kV maximum output voltage- Maximum Current 1 mA- Either Radiall Multipin or SHV connectors- Available with either positive or negative polarity- Up to 500 pA/50 pA current set / monitor resolution- Up to 100 mV/10 mV voltage set / monitor resolution- Very Low ripple, down to < 5 mV- 3 different channel grounding - Common Ground (AGxxxx) - Common Floating Return (Axxxx) - Individual Floating (A1534 only)- Independently programmable for each channel: - Output voltage - Current limit - Ramp up/down (1 ÷ 500 V/sec) - TRIP parameter- Current generator operation in overcurrent condition- Specific design for Germanium detectors (A15x0H only)

  • Battery Charger-Analyzer for small battery systems (up to 10A-Hr)

    24-400xg - JFM Engineering

    The 24-400XG is an instrument designed to charge, trickle charge and analyze (discharge) Nickel-Cadmium, Sealed Lead-Acid and other types of rechargeable batteries.With its multiple modes of operation of Constant Current Charge (dual and single rate), Constant Current & Float Charge, Constant Current & Peak Stop Charge, Automatic Discharge (analysis), Resistance Discharge (analysis) and Full Discharge (deep cycle), the 24-400XG can satisfy the requirements of most small (0 to 10 A-hr) rechargeable battery systems.The instrument features safety interlocks to protect the operator, the charger and the battery in the event of reversed polarity connection, short circuit, open circuit (no load) and Overvoltage conditions.Two large LED digital meters permit the simultaneous monitoring of voltage and current, while eight indicator lights inform of the status of the operation.

  • DC/DC - High Voltage Output Converter

    Mornsun Guangzhou Science & Technology

    MORNSUN 0.6-400W high voltage output DC DC converters can provide high voltage output up to 3,000VDC. These high voltage output series feature low ripple, low power consumption, constant current output,  high stable output voltage with low time coefficient and temperature coefficient and multiple protections such as input under-voltage, output short circuit, over-voltage and input reverse polarity protection. They are specifically designed for applications where high voltage, output voltage stability are required and output ripple requirements are high. Check out these high voltage output DC DC converters, which are suited in the fields of medical, security and some special equipment such as ultrasonic flaw detectors, photomultiplier tubes, piezoelectric devices, and capacitor charging, etc.

  • Intelligent Battery Charger-Analyzer for Large Battery Systems

    SuperMasterCharger - JFM Engineering

    The SuperMasterCharger is an instrument designed to charge, trickle charge and analyze ( discharge ) Nickel-Cadmium, Sealed Lead-Acid and other types of rechargeable batteries. With its multiple modes of operation: Constant Current Charge ( dual and single rate ), Constant Current & Float Charge, Constant Current & Peak Stop Charge, Automatic Discharge ( analysis ), Resistance Discharge ( analysis ) and Full Discharge ( deep cycle ). The SuperMasterCharger can satisfy the requirements of most large ( 10 A-hr to 100 A-hr ) rechargeable battery systems. The instrument features safety interlocks to protect the operator, the charger and the battery in the event of reversed polarity connection, short circuit, open circuit ( no load ) and Over-voltage conditions. Two large LED digital meters permit the simultaneous monitoring of voltage and current, while eight indicator lights display the status of the operation.

  • Intelligent Battery Charger-Analyzer for Battery Systems

    SuperMini - JFM Engineering

    The SuperMini is an instrument designed to charge, trickle charge and analyze ( discharge ) Nickel-Cadmium, Sealed Lead-Acid and other types of rechargeable batteries. With its multiple modes of operation: Constant Current Charge ( dual and single rate ), Constant Current & Float Charge, Constant Current & Peak Stop Charge, Automatic Discharge ( analysis ), Resistance Discharge ( analysis ) and Full Discharge ( deep cycle ). The SuperMini can satisfy the requirements of most ( Up to 40 A-hr ) rechargeable battery systems. The instrument features safety interlocks to protect the operator, the charger and the battery in the event of reversed polarity connection, short circuit, open circuit ( no load ) and Over-voltage conditions. Two large LED digital meters permit the simultaneous monitoring of voltage and current, while eight indicator lights display the status of the operation.

  • SNAPSHOT

    PH-200 - Pansco, Ltd

    The Snapshot cable checker gives professionals and layman the ability to check cables instantly upon plug-in, with no buttons pressed or displays read.  With its built-in memory, the Snapshot simply checks each cable plugged in against a correctly-configured cable pre-set by the user, and indicates the cable’s status with a  sound.  For pin-by-pin cable checking, the 〝standard check〞mode offers a plain LED-displayed check of the cable’s pins, checked automatically or manually. The Snapshot also generates a tone along the length of cables, making finding and following the cable with a tone probe a snap.  A remote unit allows testing of already-installed cables, and a built-in line tester verifies phone line polarity and detects voltage before it threatens the safety of the test unit.  A shield-test feature automatically tests cable shielding and a battery-low indicator prevents misreading results.

  • High-Performance Liquid Chromatograph Mass Spectrometer

    LCMS-2050 - Shimadzu Corp.

    The LCMS-2050 single quadrupole mass spectrometer combines the user-friendliness of an LC detector with the excellent performance of MS to provide a complete package of easy-to-use high-level performance and compactness. To make it accessible to all users, the system is enhanced with technology and functions to ensure that even technicians unfamiliar with mass spectrometers can easily and efficiently perform analysis. While delivering operational convenience on par with an LC detector, the LCMS-2050 can rapidly analyze compounds of a wide mass range with high sensitivity, continuing the tradition of excellence recognized with Shimadzu mass spectrometers. Capable of analyzing a wide range of compounds from high to low polarity, the LCMS-2050 can be used in a variety of markets and applications. This new mass spectrometer system is also equipped with data analysis features using Analytical Intelligence and eco conscious functions, which contribute to labor and energy savings in the laboratory.

  • High-Dynamics PIMag Linear Stage

    V-522 • V-524 • V-528 - Physik Instrumente GmbH & Co. KG

    Reference-class linear stage. Linear positioning stages with magnetic direct drives largely dispense with mechanical components in the drivetrain and the drive force acts directly on the motion platform. Together with precision bearings, a high travel accuracy and longer lifetime is achieved. The linear positioning stages are particularly suitable for scanning applications. PIMag® Voice Coil. Voice coil drives consist of 2 essential components: A permanent magnet and a coil, which is located in the air gap of the magnetic field. When current flows through the coil, it moves in the magnetic field of the permanent magnet. The direction of motion depends on the polarity. Thanks to their low weight and friction-free drive principle, voice coil drives are particularly suitable for applications, which require high dynamics and high velocities at limited travel ranges. High scan frequencies and precision positioning are also possible with these drives, because they are free of the effects of hysteresis.

  • Zero Bias Schottky Detectors

    Fairview Microwave Inc.

    Fairview Microwave’s line of coaxial packaged zero bias Schottky detectors feature matched inputs for excellent VSWR, voltage sensitivity levels that range from 100 to 500 mV/mW for small signal detection, negative video output polarity, and can withstand maximum input power levels up to +20 dBm CW. Operating temperature range covers 0°C to +90°C and storage temperature of -65°C to +125°C. These zero bias Schottky detectors utilize compact cylindrical package outlines that are made of passivated stainless steel and offer a variety of popular input/output SMA and BNC connector configurations that make them ideal for use with precision test and measurement, instrumentation, and subsystems assemblies. Numerous applications include power measurement, leveling pulsed signal sources, AM noise measurements, radar or missile guidance systems, monitoring system level performance, and pulsed RF measurements.

  • Cable Tracers

    162 CB - Standard Electric Works Co., Ltd

    Filter Probe● Works with any Tone Generator to identify wires.● Volume control for increasing sensitivity and adjustable to suit work environment.● 2 operation modes: Filter on / Filter off.● The auto-off function (5 minutes) prevents battery consumption.● Power supply is available in any 9V battery with a life of approximately 50 hours.● A phone jack is designed for headset or handset.● Flashlight function.Tone Generator● Tone Generator is a great tool for locating and identifying cable pairs or individual conductors.● 162 CB-G doesn't only provide the function of a tone generator, but also serves as a continuity and polarity tester.● A tone selector switch located inside the unit for selection of the fast tone or the slow tone.● Two bi-colored LEDs for Line1 and Line 2 indication of the polarities of the telephone lines.● The unit has alligator type terminals, a modular cable of 4 conductors with a strong connector.● The tone and continuity functions are only applied to Line1. (Modular connector)

  • Dual-Channel Precision Audio Analyzer with Built-In Condenser Measurement Mics

    PAA6 - Phonic Corporation

    Essential tools, such as the Phonic PAA6 Professional Audio Assistant generally wind up at the bottom of pro audio wishlists after esoteric preamps, compressors, and EQs. But more often than not, the key to great sound lies in the utilitarian gear, particularly, the Phonic PAA6 audio analyzer. If you want to get the most out of your studio equipment or PA system, the PAA6 should be at the top of your bucket list. A highly accurate measurement tool, the elegant touch screen interface of the PAA6 offers unfettered access to 61-band real-time spectrum analysis; Fast Fourier Transform (FFT); sound pressure (SPL) and dBu/dBV line voltage measurement; EQ setting; phase and polarity check; LEQ (equivalent continuous noise level); audio oscilloscope; and RT-60 functions. The PAA6 also has two built-in condenser measurement mics that can be used in six different positions. If sound is your product or passion, the Phonic PAA6 is perhaps the wisest investment you can make for your studio or sound reproduction system. Whether you're setting up monitors, treating room characteristics, calibrating listening levels, or want to know the harmonic distortion and noise characteristics of your workhorse preamps to ensure clean mixes, the Phonic PAA6 is your key to the best possible quality sound.

  • Digital Leakage Current Tester

    Educated Design & Development, Inc.

    Fast - All operator controls are located on the front panel to expedite testing. The entire test can be performed in a matter of seconds! Pays for itself in time and stress savings. Versatile - Measures Leakage Current in accordance with UL, CSA, EN, and IEC/ International Standards. Includes ability to perform open neutral, open ground, and line polarity forward/reverse test conditions. Adaptable - Universal rear panel receptacle allows for testing products with any plug configuration. Accurate - True RMS meter accurately measures both sinusoidal and non-sinusoidal waveshapes. This is important when testing products using a switch mode power supply which can generate non-sinusoidal leakage currents. Calibrated, traceable to NIST. Flexible - A front panel switch permits testing either through the power cord of the product under test, from surface/ patient connection-to-ground, or from surface/ patient connection-to-surface/ patient connection. Portable - Lightweight, with integral handle. Other Features - Product Ground Switching (grounding conductor maintained to device under test when not measuring leakage). Automatic front receptacle disconnect when configured in the 240V test mode (prevents inadvertent connection of 120V when configured for 240V operation). Proven - These are the only leakage current testers designed and supported by Product Safety experts. That is part of the reason why they have become the standard in the industry. Full technical support by experienced safety engineers.

  • Power Analyzers

    PCE Instruments

    At PCE Instruments you will find a power quality analyzer to measure the power in W, kWh or to analyze and measure harmonics. This power analyzer is a multi-function power analyzer device that measure precisely direct current, alternating current, AC-voltage, DC-voltage the intensity of DC or AC, phase rotation and idle, apparent and effective power. The reading of AC power is considered the real value and has a maximum range of 6000 Watts. While a reading is being taken, the polarity changes automatically, if negative values are taken then a minus sign will appear on the device display.Nowadays, power quality analyzers have many features such as, insulated current input, measurement of harmonics, AC and DC current measurement, AC and DC voltage measurement, frequency measurement, phase rotation measurement and idle, apparent and effective power measurement. All this data can also be logged and analyzed with the delivered PC-Software. Power analyzers of the type PCE PA 6000 can determine the energy in single-phase systems.Power quality analyzers of type PCE-GPA 62 allow the energy measurement in symmetrically loaded three-phase systems. Power analyzers of type PCE-PA 8000, PCE-360 and PCE-830 support professional power and energy measurements in single and three-phase systems.Apart from being used as energy-measuring devices, power analyzers like the PCE-830 can also be used for network analysis and the determination of harmonics and phase rotation. On our website you will find other power analyzers used in the field of electronics.

  • Long-range Surveillance Thermal Imaging Camera

    IRT303 - Wuhan JOHO Technology Co., Ltd

    Long-range Surveillance Thermal Imaging Camera IRT303IRT303 is extremely compact, durable uncooled day/night system, operating in 8-14 um waveband, with DDE image processing technology and high sensitivity, it is ideal for quick and accurate situational awareness in a variety of defense and security applications. It specially equipped with Dual-FOV, the wide FOV for find object in wide scope and then fast switch to narrow FOV looking at the target for details. IRT303 is the optimal device for super long observation purpose and target acquisition.ApplicationsLong distance surveillance or patrolLand border and coast surveillanceMarine navigation or rescueTechnical DataDetector Detector material Uncooled FPA Spectral range 8~14 m Pixels 320x240 Pitch 38 mx38 m NETD 50mK@25 C (f/0.7) Optics Lens 135mm/45mm FOV 5.2 3.9 /15.4 11.6 Focusing Motorized Optional lens 100mm/25mm, 120mm/40mm, 150mm/50mm, 180mm/60mm Image Presentation Video output 25Hz PAL/30Hz NTSC Electronic Zoom x2 Polarity BH/WH inverse Brightness & Contrast Auto/ Manual Gain Composition Auto/ Manual Power system Power supply 110~240VAC 9~14VDC (typical: 12VDC) Interfaces Command interface RS232 /RS485/ RS422 alternative Digital video interface(Optional ) Ethernet/LVDS/CameraLink Environmental Ambient temperature -40 C~+60 C Storage temperature -45 C~+60 C Range Performance Detection Range (2.3mx2.3m vehicle) 5500m Recognition Range (2.3mx2.3m vehiclet) 1800m Detection Range (1.8mx0.5m human) 2200m Recognition Range (1.8x0.5m human) 580m

  • Three-Phase Transformer Demagnetizer

    DEM60C - IBEKO Power AB

    After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores. The best way to eliminate this source of potential problems is to use demagnetizer on the power or instrument transformer.The DEM60C is a fully automatic test instrument which performs three-phase transformer demagnetization. Transformer magnetic core demagnetization requires the application of AC current with magnitude decreasing to zero. DEM60C provides this AC current by internally changing the polarity of a controlled DC current. During the demagnetization process, the instrument supplies the current at decreasing magnitude for each step, following a proprietary algorithm. It can demagnetize single-phase and three-phase power transformers.The instrument can be connected to all three phases of a power transformer to be demagnetized, on either the primary or the secondary side. If a user selects specific vector diagrams for different types of transformers, DEM60C will run a specific demagnetization procedure for each transformer type (i.e., single phase, delta, wye/star, zig-zag.) without switching the test leads.DEM60C enables safe and efficient power transformer demagnetization. The instrument automatically regulates the injection of current and discharging energy from the inductance. During and after the operation, an intrinsically safe discharge circuit with an indicator rapidly dissipates the stored magnetic energy. The discharging circuit is independent of the power supply, which improves its reliability in case of loss of power.Test currents of up to 60 A DC enable efficient demagnetization of even the largest power transformers. Using a DV Win software, it is possible to control DEM60C externally.

Get Help