Showing results: 901 - 915 of 1736 items found.
-
40-785C-452-T -
Pickering Interfaces Ltd.
The 40-785C-452-T (PXI) and 42-785C-452-T (PXIe) are dual SP4T 50GHz microwave multiplexers with automatic termination of unused signals. The 40/42-785C range of multiplexers are available as single or dual, SP6T or SP4T panel mounted multiplexers with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.
-
40-785C-553-E -
Pickering Interfaces Ltd.
The 40-785C-553-E (PXI) and 42-785C-553-E (PXIe) are triple SP6T 50GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-785C range of multiplexers are available as single or dual, SP6T or SP4T panel mounted multiplexers with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.
-
40-785C-571-E -
Pickering Interfaces Ltd.
The 40-785C-571-E (PXI) and 42-785C-571-E (PXIe) are single SP6T 67GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-785C range of multiplexers are available as single or dual, SP6T or SP4T panel mounted multiplexers with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.
-
40-785C-453-E -
Pickering Interfaces Ltd.
The 40-785C-453-E (PXI) and 42-785C-453-E (PXIe) are triple SP4T 50GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-785C range of multiplexers are available as single or dual, SP6T or SP4T panel mounted multiplexers with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.
-
40-785C-471-E -
Pickering Interfaces Ltd.
The 40-785C-471-E (PXI) and 42-785C-471-E (PXIe) are single SP4T 67GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-785C range of multiplexers are available as single or dual, SP6T or SP4T panel mounted multiplexers with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.
-
40-785C-452-E -
Pickering Interfaces Ltd.
The 40-785C-452-E (PXI) and 42-785C-452-E (PXIe) are dual SP4T 50GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-785C range of multiplexers are available as single or dual, SP6T or SP4T panel mounted multiplexers with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.
-
40-785C-552-E -
Pickering Interfaces Ltd.
The 40-785C-552-E (PXI) and 42-785C-552-E (PXIe) are dual SP6T 50GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-785C range of multiplexers are available as single or dual, SP6T or SP4T panel mounted multiplexers with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.
-
781155-01 -
NI
2-Channel, 8 V, ±3 A PXI Programmable Power Supply—The PXIe‑4154 is a specialized programmable power supply for battery simulation. It is designed to simulate a lithium‑ion battery cell’s transient speed, output resistance, and 2‑quadrant operation (source/sink). Critical to many RF and wireless applications, the simulator’s fast transient response time allows it to rapidly respond to changes in load current with minimal voltage dip, which makes the PXIe‑4154 ideal for powering devices under test (DUTs) such as RF power amplifiers, cellular handsets, and a variety of other mobile devices. To model the behavior of a battery more accurately, you can use the onboard programmable output resistance to simulate a battery’s internal resistance. For quiescent and standby current measurements, the PXIe‑4154 features integrated current measurement.
-
782856-01 -
NI
±60 V, 3 A System PXI Source Measure Unit—The PXIe‑4138 system source measure unit (SMU) delivers high power, precision, and speed. It is ideal for a broad range of applications including manufacturing test; board-level test; lab characterization with devices such as integrated circuits (ICs), power management integrated circuits (PMICs), and radio frequency integrated circuits (RFICs); and discrete devices including LEDs and optical transceivers. The PXIe‑4138 features 4-quadrant operation. The PXIe‑4138 is a hardware-timed instrument with a high-speed sequencing engine for synchronizing acquisitions between multiple SMUs. The module supports direct DMA streaming between the host PC and SMU, so you can stream large waveforms and measurement data at the full update rate and sample rate of the instrument.
-
40-614D-001 -
Pickering Interfaces Ltd.
The 40-614D-001 (PXI) and 42-614D-001 (PXIe) 16-bank, 8-channel, 1-pole multiplexers are part of the High Density 2A multiplexer module range available in 22 configurations (see 'Also in this Range' link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
40-614D-012 -
Pickering Interfaces Ltd.
The 40-614D-012 (PXI) and 42-614D-012 (PXIe) 2-bank, 16-channel, 4-pole multiplexers are part of the High Density 2A multiplexer module range available in 22 configurations (see 'Also in this Range' link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
40-614D-019 -
Pickering Interfaces Ltd.
The 40-614D-019 (PXI) and 42-614D-019 (PXIe) 1-bank, 8-channel, 16-pole multiplexers are part of the High Density 2A multiplexer module range available in 22 configurations (see 'Also in this Range' link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
40-614D-010 -
Pickering Interfaces Ltd.
The 40-614D-010 (PXI) and 42-614D-010 (PXIe) 2-bank, 64-channel, 1-pole multiplexers are part of the High Density 2A multiplexer module range available in 22 configurations (see 'Also in this Range' link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
40-614D-011 -
Pickering Interfaces Ltd.
The 40-614D-011 (PXI) and 42-614D-011 (PXIe) 2-bank, 32-channel, 2-pole multiplexers are part of the High Density 2A multiplexer module range available in 22 configurations (see 'Also in this Range' link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
40-614D-013 -
Pickering Interfaces Ltd.
The 40-614D-013 (PXI) and 42-614D-013 (PXIe) 2-bank, 8-channel, 8-pole multiplexers are part of the High Density 2A multiplexer module range available in 22 configurations (see 'Also in this Range' link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.