Showing results: 5401 - 5415 of 5678 items found.
-
782705-02 -
NI
The NI‑5782 is ideal for applications that require the acquisition and generation of IF or baseband signals with in-line, real-time processing. You can analyze acquired signals in the PXI FPGA Module for FlexRIO to perform measurements and generate response signals. Application areas include RF modulation and demodulation, channel emulation, bit error rate testing (BERT), signal intelligence, radio frequency identification (RFID) and near-field communication (NFC) test, real-time spectrum analysis, and software defined radio (SDR).
-
782865-01 -
NI
The NI‑5742 provides simultaneously sampled analog output channels for signal generation. It also features single-ended, DC-coupled inputs and general-purpose digital input and output lines for system stimulus and control. The NI‑5742 is ideal for applications requiring high-channel density and the power of a user-programmable FPGA. Each channel has a user-configurable sample rate, and data is written directly from the FPGA. To use the NI‑5742, you must pair it with a compatible PXI FPGA Module for FlexRIO.
-
782864-01 -
NI
The NI‑5741 provides simultaneously sampled analog output channels for signal generation. It also features single-ended, DC-coupled inputs and general-purpose digital input and output lines for system stimulus and control. The NI‑5741 is ideal for applications requiring high-channel density and the power of a user-programmable FPGA. Each channel has a user-configurable sample rate, and data is written directly from the FPGA. To use the NI‑5741, you must pair it with a compatible PXI FPGA Module for FlexRIO.
-
42-203-001 -
Pickering Interfaces Ltd.
The 40-203-001 (PXI) and 42-203-001 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 3 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
42-203-002 -
Pickering Interfaces Ltd.
The 40-203-002 (PXI) and 42-203-002 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 6 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
40-203-001 -
Pickering Interfaces Ltd.
The 40-203-001 (PXI) and 42-203-001 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 3 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
40-203-002 -
Pickering Interfaces Ltd.
The 40-203-002 (PXI) and 42-203-002 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 6 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
M9485A -
Keysight Technologies
1 MHz to 9 GHzUp to 12-ports in one chassis, 24-ports in two chassis Various applications - full N-port cal, FOM, Pulse, time-domain, noise figure and gain compression analysis capability Improve accuracy, yield & margins with the best PXI VNA speed, dynamic range, trace noise and stability Improve throughput with fast cycle time: 5 msec at 201 points, 2-port calVarious configuration with standard test set and configurable test set
-
781502-01 -
NI
8-Slot, Spartan-3 FPGA, Ethernet CompactRIO Chassis - The NI-9148 is a rugged Ethernet chassis that you can use to add C Series I/O modules to any standard Ethernet network. You can program the chassis using scan-mode for fast expansion of your real-time system or using the onboard FPGA for inline processing and high-speed I/O and control. The NI-9148 enables you to add high-performance I/O to your PC-based application or expand your CompactRIO, PXI, or industrial controller application.
-
40-675B-002-5/32 -
Pickering Interfaces Ltd.
The 40-675B-002-5/32 (PXI) and the 42-675B-002-5/32 (PXIe) are 5-channel, 32-pole multiplexers and are part of our range of very high density low cost multiplexer modules. These modules are suitable for signal routing in high channel count ATE and data acquisition systems. They use high quality electromechanical signal relays allowing each channel to switch current up to 1 A at 150 VDC/100 VAC. Connections are made via a front panel 200-pin connector.
-
40-675B-002-10/16 -
Pickering Interfaces Ltd.
The 40-675B-002-10/16 (PXI) and the 42-675B-002-10/16 (PXIe) are 10-channel, 16-pole multiplexers and are part of our range of very high density low cost multiplexer modules. These modules are suitable for signal routing in high channel count ATE and data acquisition systems. They use high quality electromechanical signal relays allowing each channel to switch current up to 1 A at 150 VDC/100 VAC. Connections are made via a front panel 200-pin connector.
-
40-675B-002-24/8 -
Pickering Interfaces Ltd.
The 40-675B-002-24/8 (PXI) and the 42-675B-002-24/8 (PXIe) are 24-channel, 8-pole multiplexers and are part of our range of very high density low cost multiplexer modules. These modules are suitable for signal routing in high channel count ATE and data acquisition systems. They use high quality electromechanical signal relays allowing each channel to switch current up to 1 A at 150 VDC/100 VAC. Connections are made via a front panel 200-pin connector.
-
40-675B-002-49/4 -
Pickering Interfaces Ltd.
The 40-675B-002-49/4 (PXI) and the 42-675B-002-49/4 (PXIe) are 49-channel, 4-pole multiplexers and are part of our range of very high density low cost multiplexer modules. These modules are suitable for signal routing in high channel count ATE and data acquisition systems. They use high quality electromechanical signal relays allowing each channel to switch current up to 1 A at 150 VDC/100 VAC. Connections are made via a front panel 200-pin connector.
-
ViTec Co. Ltd
The hardware part of the measuring system of the test bench is built on the basis of equipment from National Instruments and contains the following components: multichannel switching system for signal conditioning SCXI, interrogation system of "fast-changing" voltage signals and AC power PXI, including M-series NI PXI-6220 board for SCXI module measuring channels, a high-performance Ethernet controller for the distributed I / O system and industrial control cFP-2110 running operating systems hard real-time, multi-channel vibration measurement complex K-5101.
-
ViTec Co. Ltd
The hardware part of the measuring system of the test bench is built on the basis of equipment from National Instruments and contains the following components: multichannel switching system for SCXI signal conditioning, interrogation system of "fast-changing" voltage signals and AC power PXI, including M-series NI PXI-6220 board for SCXI module measuring channels, a high-performance Ethernet controller for the distributed I / O system and industrial control cFP-2110 running operating systems hard real-time, multi-channel vibration measurement complex K-5101.