Filter Results By:
Products
Applications
Manufacturers
Noise Sources
create signal disturbances for the purpose of noise instrument calibration.
See Also: Pink Noise, Noise Generators
-
product
High Power Noise Sources
NS-7001
The NS-7001 is high-power noise source specifically designed to operate in the 2.11-2.17 GHz UMTS band. It features flat output power that is regulated over a wide temperature range with high rejection outside the operating band of interest. Logic control is provided to enable/disable the noise source and an internal BIT function continuously monitors the output power. Other frequency bands and power levels are available.
-
product
Surface-Mount Noise Sources
Mercury’s family of surface-mount noise sources provides exceptional performance in a compact and easy to integrate package. These products are ideal for applications such built-in test and dithering circuits where the system requirements drive a need for compact, surface mount technology.
-
product
Precision Calibrated Noise Sources
ELVA-1's calibrated noise source ISSN-XX series delivers a uniform level of noise power spectral density within the whole waveguide frequency range. Sources are available in eight waveguide bands covering 26.4-170 GHz.
-
product
Calibrated, Integral Isolator Noise Sources
Calibrated, Integral Isolator Noise Sources by Pasternack
-
product
Broadband Calibrated Noise Sources
Fairview Microwave’s calibrated noise sources cover frequency bands from 10 KHz to 18 GHz. Their performance specifications include output ENR levels ranging from 15 dB to 30 dB and typical VSWR levels as low as 1.25:1. Depending on the model, calibrated frequency points are at 10 MHz, 100 MHz, 1000 MHz, 2000 MHz and 1 GHz steps. The temperature coefficient of these noise sources is < 0.01 dB/°C and noise output variation is < 0.1 dB/%V.
-
product
Power Sensor and SNS Noise Source Cable (6.1m/20 feet)
11730C
The Keysight 11730 series power sensor cables are used with the 8480 and E-series power sensors (except the E9320 family of peak and average sensors). These cables are designed to reduce RFI effects on low power readings with an improved shielding design in the cable itself. Cables may be ordered individually or in pairs in any combination desired for single and dual-channel measurements.
-
product
Microwave / RF Synthesizers, Test & Measurement
Berkeley Nucleonics Corporation
The 825-M is an agile ultra-low phase noise RF signal source from 8 kHz to 20 GHz RF Synthesizer. It is available in single-channel or multichannel configurations. A single channel 825-M is packaged in a compact enclosure, or can be ordered with a touch-screen display, or a 1U 19" rackmountable version. The multi-channel version (2, 3, or 4 channels) is packaged in a 19” 1U rackmount enclosure.
-
product
Handheld Broadband Noise Generator
NS-1
The Model NS-1 is a handheld broadband white Gaussian noise source. It generates a wide, even, RF noise-signal. The NS-1 is popular for testing network components and aligning a building's coaxial cable network. The NS-1's noise-signal is also used to provide the RF source for measuring insertion loss of cable, splitters, taps and more.
-
product
Broadband Coaxial Noise Sources
Our integrated noise modules contain all the required biasing circuitry and only need a positive voltage to activate for an easy installation. Since they typically do not contain amplification, the raw noise output from the diode is seen at the output of the module resulting in a maximum ENR of approximately 35dB. Primary applications include system built-in test and laboratory use.
-
product
RF Noise Source
NS-3
The NS-3 Broadband RF Noise Generator provides an extremely flat AWGN (Additive White Gaussian Noise) signal from 5 to 2150 MHz. The output level adjusts in 0.1 dB steps over a 30 dB range.The bench-top configuration is standard and an optional two unit rack enclosure is available. The RS232 or USB remote control interface simplifies its use in automated test and factory ATE environments. The NS-3's combination of range, versatility and value make it the ideal general purpose broad-spectrum signal source for bench and ATE applications, including C/N, BER, MER, PER testing and rain fade simulation.
-
product
Millimeter-Wave Noise Source, R-band, 26.5 to 40 GHz
R347B
The Keysight R347B noise source covers a 26.5 to 40 GHz frequency range. This waveguide noise source allows you to make accurate and convenient noise figure measurements on millimeter-wave devices. The R347B provides highly precise broadband noise at the input of the system or component under test. The noise figure meter then processes the ON/OFF ratio of noise power present in the system IF, and provides an accurate reading of noise figure and gain. The R347B noise source has remarkable ENR stability over time, which allows longer recalibration cycles and more accurate noise figure measurements.
-
product
SNS Series Noise Source 10 MHz to 18 GHz (ENR 6 dB)
N4000A
The SNS series N4000A noise source is designed for accurately measuring devices with low noise figure, with a frequency range of 10 MHz to 18 GHz and nominal ENR 6 dB.
-
product
Speaker Component Checker
Cab Driver
Whirlwind Music Distributors, Inc.
The CAB DRIVER is a test device for checking the operation of the speaker components within enclosures. A pink noise signal source is sent through pushbutton selectors to an assortment of speaker connectors, including Speakon NL8 and NL4, 1/4" TS and banana jacks. Speaker/ Polarity/ Impedance/ Pink Noise Generator
-
product
6.5-Digit Low Noise Power Source, 32 W, 210 V, 3 A, 2-Channel
B2962B
The Keysight B2961B Series 6.5-digit low noise source power supplies provide a power supply and source solution that meets the difficult measurement challenges researchers, designers, and developers face working on advanced components, circuits, and materials.
-
product
Multi-Channel, Programmable Current Source
CS-48-100
The Model CS-48-100 is a multi-channel, programmable current source. Developed for both semiconductor and digital superconductor electronics, it is computer-controlled and features 48 low noise current source outputs. Each source output has the capability to both set and read back currents and can be set to a zero current high Z mute state. Each of the 48 sources are optically coupled for control and are sourced from their own secondary winding for complete galvanic isolation. The device consumes a maximum of only 80 W and handles a maximum load current of 4.8 A total over all outputs. Operating over a range of 0-100 mA on each channel, the device features accuracy of +/-25 ?A. The mute state can be set thru a rear panel interlock or from the front panel button for maximum circuit protection. The unit can be mounted in a standard-sized rack.
-
product
High-Current, Ultra-Low Noise Filter, 21 V / 500 MA, 10 Ω
N1298A
The N1298A Series is a collection of low noise filters for the Keysight B2960 Series 6.5-digit low noise source.
-
product
Sound Power Measurement
Dewesoft sound power measurement solution merges the best of both worlds: widely established sound power measurements with familiar, distinctive user interface and industry unmatched adaptability. Rate and compare different noise sources with ease and exactness while simultaneously monitor any number of additional parameters.
-
product
USB Smart Noise Source, 500 MHz To 50 GHz, 5 DB ENR Nominal
U1832C
The USB-powered (USB TMC compliant) U1832C provides broadband noise figure measurements from 500 MHz – 50 GHz with modular signal analyzer, benchtop X-Series signal analyzers and Fieldfox
-
product
High-Density Precision SMU (100 PA, 30 V)
PZ2130A
The Keysight PZ2130A is a high-channel density precision source / measure unit (SMU) with 5 channels per module that saves space at a low cost per channel for a wide range of applications requiring numerous precision power supplies. Its seamless current measurement ranging function eliminates the time it takes to change the range and expands the dynamic range to cover multiple measurement ranges, which reduces test duration. These capabilities make the PZ2130A suitable for applications that require numerous precision power supplies, such as semiconductor reliability tests and integrated circuit (IC) tests. The Keysight PX0107A low noise filter adapter lowers its voltage source noise level, which makes the PZ2130A suitable for noise sensitive applications such as quantum computing as well.
-
product
Noise Source, 10 MHz to 18 GHz, nominal ENR 15 dB
346B
The Keysight 346B noise source is the ideal companion to Keysight's noise figure solutions. Since it is broadband (10 MHz to 18 GHz), it eliminates the necessity for several sources at different frequency bands. The low SWR of the noise source reduces a major source of measurement uncertainty; reflections of test signals. The 346B's high ENR, low SWR, and variety of connectors make it a general-purpose noise source. Add special option H01 for high ENR (21 dB typical) to measure high noise figure devices, or option H42 for measuring Direct Broadcast Satellite (DBS) low noise block converters.
-
product
Noise Source Family
347
The R347B waveguide noise source cover the R-band (26.5 to 40 GHz frequency range), while the Q347B model cover the Q-band (33 to 50 GHz frequency range), allows you to make accurate noise figure measurements on millimeter-wave devices.
-
product
Sound Intensity Measurement
Sound Intensity MeasurementA perfect tool for sound intensity level measurement and noise source determination brought to an entirely new level by Dewesoft. The solution brings a simple and intuitive measurement process while offering the utmost precision and industry unmatched adaptability.
-
product
Noise Location Package
Type HFDF
National RF’s Type HFDF high frequency location system is a proven noise hunting and location directional antenna system that allows you, in many cases, to walk right up to the source of High Frequency (HF) noise! Used by several power companies around the United States, professional noise hunters, and other communications specialists, the HFDF has located noise sources that emanated from pole power transformers, arcing electric fences, CATV in-line amplifiers, plasma TV screens, and even Marijuana grower’s heating lamps! The system incorporates several plug-in, tunable magnetic loop sensors of a proprietary National RF design, that cover the frequency range between 1.8 MHz and 55 MHz. The unit is packaged in a hand-held, lightweight metallic enclosure, with a pistol grip and a magnetic compass mounted on top. The compass is used to get magnetic bearings to the noise source, which may be plotted on a map to triangulate, and ultimately pin-point, the location of the noise source. In certain cases, our customers tell us that they have been able to walk right up to the interfering noise source and correct the situation on the spot!
-
product
Noise Figure Analyzer, Multi-touch, 10 MHz to 40 GHz
N8976B
The N8976B high performance noise figure analyzer is designed to make fast, accurate and repeatable noise figure measurements. When paired with an SNS Series noise source and U7227 Series USB preamplifier the ENR data from the SNS and USB preamplifier data automatically downloads into the N8976B.
-
product
Millimeter-Wave Noise Source, Q-band, 33 To 50 GHz
Q347B
The Q347B waveguide noise source (33 to 50 GHz frequency range), allows you to make accurate noise figure measurements on millimeter-wave devices...
-
product
RF Reference Sources
The 27 GHz 96270A and 4 GHz 96040A Low Phase Noise Reference Sources are designed specifically for RF calibration, featuring a calibration-oriented interface, precision signal level and attenuation, high signal purity and precision low distortion modulation. Both instruments simplify the process of RF calibration by reducing the amount of equipment and simplifying the calculations required.
-
product
1000W Ferroresonant Power Supply
Series PRR
Kepco's PRR are 1000 Watt rack mounted laboratory systems power supplies that offer the low cost and very high dependability of ferroresonant voltage stabilization.The ferroresonant stabilizing technique provides extraordinary isolation from a wide variety of source noise. It is inherently short-circuit proof and cannot expose delicate loads to overvoltage hazards. Hence no crowbar, fuses, or bounding circuits are needed. Ferroresonant power supplies use no noise-producing switches or oscillators. Voltage setting is independent of delicate control settings or diode references and requires no comparators, references, or limiters. Efficiency is 70-80%.