Showing results: 136 - 150 of 1072 items found.
-
Extech MG302-MTK -
Extech Instruments Corporation
The Extech MG302-MTK Motor and Drive Troubleshooting Kit includes three compact tools for troubleshooting three phase motors and drives. The first tool in the kit is the MG302, a 13 Function Wireless True RMS Multimeter/Insulation Tester featuring 125 V, 250 V, 500 V, and 1000 V test voltages. It also features insulation resistance from 0.001 MOhm to 4000 MOhm, auto discharge of capacitive voltage, a lock power on function for hands free operation, data hold, min/max, relative mode, auto power off and more at a CAT IV 600 V safety rating. The second tool is the 480403 Motor Rotation and Three Phase Tester that features a double molded, durable housing and CAT III 600 V safety rating. The third tool in this kit is the MA435T 400 A True RMS AC/DC Clamp Meter with a built in non-contact voltage detector, 10 functions and a CAT III 600 V safety rating.
-
Veer Electronics
Power Parameter MeasurementVoltage (V), Current (I), Power (P), Power Factor (PF), Apparent Power (VA), Reactive Power (VAR), Frequency (F) etc. Physical Parameter MeasurementTorque (Kgm), Output Power (Po), Efficiency of Motor, RPM, CRPM, % Slip etc.
-
MR-1A -
TEGAM Inc.
# No need to disconnect drive shaft couplings# Identifies open windings# Protects user and equipment# Reliable, solid state components# Shirt pocket size, 48" leads with heavy duty 1/2" clips, works on most sizes and types of 3 phase motors
-
Intepro Systems
Drive and motor systems present unique challenges for test systems and Intepro combines regenerative active electronic loads to reduce the energy needed to do the tests as well as sophisticate instruments and supply voltages to test these demanding applications and provide meaningful results for the electrical and mechanical power parameters.
-
MEXA-1300R -
HORIBA, Ltd.
MEXA-1300R is a motor exhaust gas analyzing system for two and four stroke engine assembly lines and has an integrated sample handling system for removal of oil and moisture. The measurement of CO, CO2, HC and O2 (optional) in exhaust gases is made simply by inserting the sample probe into the tail pipe. AFR and Lambda are also calculated from the exhaust gas concentrations.
-
M-661 · M-662 -
Physik Instrumente GmbH & Co. KG
M-661 and M-662 PILine translation stages offer accelerations to 5 g with millisecond response and velocities to 500 mm/sec in an extremely compact package. Providing travel ranges to 20 mm, they are among the smallest motorized translation stages currently on the market. Both models are designed for open-loop operation (a similar closed-loop stage with linear encoder is available as model M-663. The M-662, with its square footprint, is also suitable for use in XY configurations. For applications where the smallest dimensions are essential, the P-652 micro stage is offered.
-
U-shape Core-less -
Mirae Corporation
Is a compact design product for efficient movement in a small area.
-
MEXA-ONE -
HORIBA, Ltd.
MEXA-ONE offers an intuitive user interface with a highly efficient hardware and software design.This results in increased testing efficiency and economical facility operation, while enhancing reliability and accuracy. These advancements are possible because the MEXA-ONE software employs new "HORIBA ONE PLATFORM". This platform integrates the test devices in an emission cell into a single user interface, increasing efficiency and optimizing user control over the entire testing process.
-
Vogelsang & Benning
Endurance test bench on which up to five drives can be tested at the same time. The drives / DUTs are electrically connected to resistors and driven by a servo drive according to a predefined driving profile. This exam can take up to several days. It detects currents, speeds and temperatures.
-
BK2019B -
BaKo Co., Ltd
With the BK2019B, you can test for open/short circuits, operating current and even vibration level. Because it has only one purpose, it is very easy to set up and use and it's so small it can fit into the average briefcase.
-
MOTOMEA
*Low-cost portable unit with all the major motor performance tests of the standard MotorLine® system.*Connects directly to USB 2.0 port.*Performs QA testing on 100% of production without compromising line throughput (up to 10 motors per minute), reducing costs of defective products.*Determines acceptability to user predefined PASS/FAIL limits on production lines.*Provides motor performance data, from stall up to no-load, within seconds, including: torque, speed, current, voltage, input power, output power, power factor, time, efficiency, direction of rotation.*Provides dynamic performance tests data, including: speed and torque spectrum, speed and torque oscillations, friction torque, friction spectrum, friction output power, cogging torque level.*Motor performance data can be recorded in the system database for comparison and statistical analysis.*Motor power switching is done automatically by the system.*Motors can be tested inside their applications.*Test results are provided graphically and tabulated.*Test reports in PDF and Excel format.*Capability for integration with third party devices, such as hipot & insulation resistance testers.
-
D-9005 FMT -
Jabbals
The PC Based Automatic Motor Analyzer is the most comprehensive tester designed to automatically check the quality of Motors in fast paced production motor shops.
-
MCE -
PdMA Corporation
The MCE? (Motor Circuit Evaluator) is a comprehensive static motor tester that produces detailed analyses of motor and circuit conditions in as little as three minutes. Analysis of the motor and associated circuits through MCE? testing allows for the detection of electrical faults in any one of the five fault zones.
-
SURE Engineering cc
The SURETECH Motor Insulation Monitor measures insulation resistance to earth of electric motors when themotor stops. Motors running from mains (380 / 220V) and higher voltages up to 6.6kV can have their insulationcontinuously monitored.
-
Hilkar
Motor starting reactors are used to reduce voltage during starting of large 3 phase motors while limiting inrush currents.