Filter Results By:

Products

Applications

Manufacturers

Motor

propels movement.

See Also: Electric Motor, Automobile, Vehicle, Speed, Motor Test


Showing results: 1051 - 1065 of 1084 items found.

  • Vibration And Packaging Equipment

    LR Environmental Equipment Co. Inc.

    LR/RAD Drop Testers are available to simulate the impact a package would encounter during handling and shipment. The machine is air actuated to provide a reliable long life. Drop height ranges from 12-60 inches.The Drop Tester is supplied with a variety of standard features to earn its reputation as the industry standard: motor hoist with hand held control box to automatically raise and lower drop arm with package in place, Microswitch to preset drop height for repeatable drops, drop height indicator, remote hand switch actuated and a one inch vertical drop prior to drop arm swing to insure that package is not subject to rotation. LR/RAD Drop Testers are designed so packages may be released from any angle and be assured of landing in the same position. Special fixtures are available to allow for corner and edge drops.

  • Tensile Strength Tester

    Atico Export

    Capacity of Tester with accuracy of 100g : 250 Kgf. and 500 Kgf.Capacity of Tester with accuracy of 10g : 20 Kgf, 50 Kgf and 100 KgfS Type Load Cell fixed with Top GripTraverse Speed: 300 & 100mm /min.Grip Separation: 1000 mmGrip Separation: 25 mmTop Grip is fixed and Bottom Grip is Movable Type.Elongation measurement by Steel Scale and Digital Counter Meter Both.Digital Display of Load and Elongation.Peak value of last test can be read.User friendly key panel with switch of zero setting and peak value of last testMotor: 1/2 HP single phase 220V 50 Hz. ( for Capacity up to 100 Kgf )Motor: 1 HP single phase 220 V 50 Hz ( for Capacity up to 500 Kgf)Power: 220 V AC 50 Hz.Safety device by limit switch to protect from over traverse.

  • Heavy Duty Dynamometers

    MD-250-HD - Mustang Dynamometer

    The MD-250-HD series dyno (SE/DE) was designed to be a performance dynamometer first with the added benefit of being able to test 2-wheel-drive heavy-duty vehicles such as truck, buses and commercial vehicles in addition to the standard car or light duty pick-up. The 250-HD is certified in the states of Colorado, Nevada and Utah for use in loaded-mode diesel smog testing programs because of its accuracy and reliability. No other dyno in its class offers more value or better in-house motor vehicle testing capabilities than the Mustang MD-250-HD. For starters, the MD-250-HD boasts a 1,500 horsepower measurement capacity at a top speed of 175 mph and a powerful air-cooled eddy current brake provides the MD-250-HD-SE with 900-hp worth ofloading capacity for steady state testing. Loading capacity can be increased to 1,500-hp via the optional DE model. The 250-HD can be upgraded to the 250-HD-SE-M via the addition of a 100 or 200 hp AC motor for transient testing of electric buses to measure range and regeneration or for emissions testing of IC engines. Do not be fooled by its compact size – the MD-250-HD is a serious dynamometer with serious tuning capabilities. The MD-250-HD uses a powerful eddy current power absorber, a frictionless, air-cooled braking device, to enable it to apply variable and steady state loading. A complete control and data acquisition system lets you design a wide range of tests or select from a host of pre-configured tests included with the standard system. The 250-HD’s four roller design makes setting up vehicles a snap – simply drive onto the 250-HD and let the tires settle in between the rollers. The 250-HD can be installed above-ground or below-ground, it’s your choice. The above-ground system utilizes an optional premium platform and ramp system with an above-ground restraint kit. The addition of an axle pull-down kit help keep the tires from slipping or trying to “climb out” of the rollers.

  • PC Controlled Bench Top Power Analyzer

    PA2100 - Powertek LLC

    The PA2100 is a PC controlled bench top power analyzer, allowing several electrical power measurements to be taken simultaneously during testing - from just one set of input connections. The PA2100's power measurement ability is a must in research and development, manufacturing and required for certification and traceability of manufactured goods. In addition to power measurements, apparent power (VA), harmonics, voltage, current, power factor can all be viewed and stored with ease. The PA2100 wattmeter simply connects between the ac supply and the load, various current transformer options allow measurement with any size of current from 10mA to 10000A. Typical watt meter applications include appliance testing; microwave ovens, electric stoves, heating, air conditioning, TVs, monitors, computers, electronic lighting, fans and motor controllers. Powertek wattmeters are equipped with 4mm/banana safety terminals along with optional "breakout" boxes and clamp current probes for fast and safe measurement.

  • 4 Digit Temperature Meter (5 Channels)

    CM1-TX5 - Chuan Sheng Electronics Co., Ltd.

    RS-485 Modbus RTU protocol (with communication LED indicator)RS-485 address 1~255Communication Baudrate 9600, 19200, 38400, 57600, 115.2KParity check N81, N82, E81, O81Input 5 channels of signal selectable:thermocouple/PT100.5 channels of input can be set to play 1~10 seconds loop display.1~5 channels of display value limits can be set, and the number of channels of carousel display screens can be set by yourself.5 channels of input signals with LED unit cycle display.Standard 2 groups of alarms Hi, LO with communication LED indicators to ensure the normal operation of the field system.Suitable for HVAC refrigeration and air conditioning PLC, DDC, PC brands to achieve remote real-time monitoringCan be used in solar panels, medical control, clean room, ice water host, boiler, motor, chemical plant, power plant, school energy-saving control, remote control of power monitoring panel

  • Solar Pump Inverter

    45-100kw - Shenzhen Setec Power Co., Ltd.

    Solar pumping system is composed of a solar array,a pump and a solar pumping inverter. Based on the design philosophy that it is better to store water than electricity , there is no energy storing device such as storebattery in the system. The solar array,an aggregation of many solar modules connected in series and parallel , absorbs sunlight radiation and converts it into electrical energy , providing dynamical water for the whole system. The pumping inverter controls and adjusts the system operation and converts the DC produced by solar array into AC to drive the pump , and adjust the output frequency intensity to realize the maximumpower point tracking (MPPT) . The pump, drive by 3-phase AC motor,can draw water fromthe deep wells or rivers and lakes to pour into the storage tank or reservoir , or directly connect to the irrigation system ,fountain system,ect. According to the actual systemdemand and installation conditions,different types of pump such as centrifugal pump, axial flow pump,mixed-flow pump or deep-well pump can be used.

  • Solar Pump Inverter

    22-37kw - Shenzhen Setec Power Co., Ltd.

    Solar pumping system is composed of a solar array,a pump and a solar pumping inverter. Based on the design philosophy that it is better to store water than electricity , there is no energy storing device such as storebattery in the system. The solar array,an aggregation of many solar modules connected in series and parallel ,  absorbs sunlight radiation and converts it into electrical energy , providing dynamical water for the whole system. The pumping inverter controls and adjusts the system  operation and converts  the  DC produced  by  solar array  into  AC  to drive the pump ,  and adjust  the output  frequency  intensity to realize the maximumpower point tracking (MPPT) . The pump, drive by 3-phase AC motor,can draw water fromthe deep wells or rivers and lakes to pour  into the storage tank or reservoir , or directly connect to the irrigation system ,fountain system,ect. According to the actual systemdemand and installation conditions,different types of pump such as centrifugal pump, axial flow pump,mixed-flow pump or deep-well pump can be used.

  • Omni-λSeries Imaging Spectrograph

    Omni-λi - ZOLIX

    Zolix Imaging Spectrometer includes different focal length 320mm, 500mm, 750mm; ◆Manual micrometer adjustable slits for precision control of incoming light. Motorized Slit and fixed slit is optional. • More than 100 gratings for the best spectral range, throughput and dispersion to meet your application◆DSP controlled stepping motor scanning system provides superior precision and repeatability of wavelength positioning◆Optional internal shutter or six-position filter wheel for experiments requiring background removal or signal attenuation◆Installation and set-up through USB 2.0 computer interfaces • Stand-alone Omni Series monochromator control software for basic scanning and calibration. Also includes utilities for grating updates and communications◆ Active X control support Visual Basic, C++ and Delphi drivers allow users to design their own acquisition programs◆ZolixScan data acquisition software provides a simple user interface for easy data acquisition and experimental set-up

  • 2 phase 120/240VAC SDP-30KW split phase inverter

    SDP-30KW - Zhejiang Sandi Electric Co., Ltd

    SANDI SDP series Pure Sine Wave Inverter is the one of the most advanced technology DC to AC conversion products in the world, it’s suitable use for areas without electricity, providing a complete power solution for strict demand applications. With SVPWM technology it has high conversion efficiency, high instantaneous power and low losses power output pure sine wave, applying to capacitive, inductive and nonlinear mixed-load, with superior load capacity, perfect protection function: overload, short circuit, low/over battery voltage, improper operation etc, which won’t cause mechanical failures. This Inverter is very suitable for solar power systems, wind power generation systems, wind and solar hybrid generation systems. The inverter can supply AC power to all kinds of electric equipment, air conditioners, electric motors, refrigerators, fluorescent lights, televisions, electric fans and other industrial power supply.

  • X-Ray Flaw Detectors

    XXQ Series - Testech Group Co., Ltd

    1. Checking the software and hardware itself after start the machine2. Excellent anti-jamming performance, which can adapt for field operation without power supply, because of the motor supports3. Can adjust exposure parameters with keys ( easy operation.)4. Has the function of Delay time opening HV. Convenient for operator keep away from dangerous field5. Can adjust high voltage slowly for protecting X-ray generator6. Automatically controlling according to 1:1 working and rest operating way, the longest continuous exposure period is 5 minutes.7. Including complete protecting system: over KV, over KV, low mA, over mA, over temperature and optical-sound alarming8. Convenient for repairing and maintenance9. Much more Substance for structure designing, much more convenient for local operation10. Time can be changed for±0.3 according to the power supply net to make the exposure more precise

  • Hazardous Location Syringe Pump

    100HLf - Teledyne LABS

    Teledyne LABS HLf-Series pumps give you the same accurate, predictable flow and pressure control as our standard D-Series, while conforming to safety standards for use in UL Class I, Division 2, Groups A B C & D, T4 environments. The hazardous location rating is achieved through internal design modifications including the use of brushless DC motors. This approach eliminates the need for purge boxes or other additional safety devices. Wetted materials are compat​ible with most aqueous and organic liquids, corrosive solutions, heated fluids, liquefied gases, viscous fluids, or slurries and pastes. If needed, optional materials such as Hastelloy C-276 are available on request. The HLf controller has a keypad and LCD, as well as built-in and optional interfaces for computer control and other devices. Programming is easy and flexible, with instant access to menu screens even when the pump is running. This allows you to change operating parameters on the fly.

  • Hazardous Location Syringe Pump

    1000HLf - Teledyne LABS

    The Teledyne ISCO HLf-Series pumps give you the same accurate, predictable flow and pressure control as our standard D-Series, while conforming to safety standards for use in UL Class I, Division 2, Groups A B C & D, T4 environments. The hazardous location rating is achieved through internal design modifications including the use of brushless DC motors. This approach eliminates the need for purge boxes or other additional safety devices. Wetted materials are compatible with most aqueous and organic liquids, corrosive solutions, heated fluids, liquefied gases, viscous fluids, or slurries and pastes. If needed, optional materials such as Hastelloy C-276 are available on request. The HLf controller has a keypad and LCD, as well as built-in and optional interfaces for computer control and other devices. Programming is easy and flexible, with instant access to menu screens even when the pump is running. This allows you to change operating parameters on the fly.

  • Hazardous Location Syringe Pump

    500HLf - Teledyne LABS

    The Teledyne LABS HLf-Series pumps give you the same accurate, predictable flow and pressure control as our standard D-Series, while conforming to safety standards for use in UL Class I, Division 2, Groups A B C & D, T4 environments. The hazardous location rating is achieved through internal design modifications including the use of brushless DC motors. This approach eliminates the need for purge boxes or other additional safety devices. Wetted materials are compatible with most aqueous and organic liquids, corrosive solutions, heated fluids, liquefied gases, viscous fluids, or slurries and pastes. If needed, optional materials such as Hastelloy C-276 are available on request. The HLf controller has a keypad and LCD, as well as built-in and optional interfaces for computer control and other devices. Programming is easy and flexible, with instant access to menu screens even when the pump is running. This allows you to change operating parameters on the fly.

  • Hazardous Location Syringe Pump

    260HLf - Teledyne LABS

    Teledyne LABS HLf-Series pumps give you the same accurate, predictable flow and pressure control as our standard D-Series, while conforming to safety standards for use in UL Class I, Division 2, Groups A B C & D, T4 environments. The hazardous location rating is achieved through internal design modifications including the use of brushless DC motors. This approach eliminates the need for purge boxes or other additional safety devices. Wetted materials are compatible with most aqueous and organic liquids, corrosive solutions, heated fluids, liquefied gases, viscous fluids, or slurries and pastes. If needed, optional materials such as Hastelloy C-276 are available on request. The HLf controller has a keypad and LCD, as well as built-in and optional interfaces for computer control and other devices. Programming is easy and flexible, with instant access to menu screens even when the pump is running. This allows you to change operating parameters on the fly.

  • NI-9244, 400 Vrms L-N, 800 Vrms L-L, 50 kS/s/ch, 24-Bit, 3-Phase C Series Voltage Input Module

    783106-01 - NI

    400 Vrms L-N, 800 Vrms L-L, 50 kS/s/ch, 24-Bit, 3-Phase C Series Voltage Input Module - The NI‑9244 performs single-ended analog input. The wide measurement range makes it ideal for high-voltage measurement applications such as phasor measurements, power metering, power quality monitoring, industrial machinery, and motor test. You can also perform transient and harmonic analysis with high-speed simultaneous sampling. The NI‑9244 offers three channels, so you can connect single‑ or three‑phase measurement configurations such as WYE and delta. You can incorporate the NI‑9244 into systems to meet standards such as IEC 61010‑1, C37.90 and C37.60, IEC 60255‑22‑(1:7), IEC 60255‑1, C37.188 Class M and P, EMC section of IEC 60870, EMC sections of IEC 61850, IEC 61000‑4‑30 Class S, and IEC 61000‑4‑7.

Get Help