Filter Results By:

Products

Applications

Manufacturers

Model

construction of a concept.

See Also: Modeling, Modelling, Modelers, Human Body Model, Charged Device Model


Showing results: 1141 - 1155 of 4104 items found.

  • Thermometer

    HX-E18 - HuiXia Supply Co., Limited

    Model: Digital roast meat milk thermometer HX-E18Temperature range: -50-200c, -58-392FProduct dimension: 215x30x27mmWelght Approx: 49gMaterial: PlasticPackage: White paper box

  • Oscilloscope 70/100/200 MHz, 4 Analog Channels

    DSOX1204G - Keysight Technologies

    4 channel and built-in WaveGen model of the InfiniiVision 1000 X-Series entry-level oscilloscopes that can be upgraded from 70 MHz to 100 MHz or 200 MHz.

  • DC Gaussmeter

    GM1-HS - Alpha Lab, Inc.

    The Model GM1-HS measures the strength and polarity of magnetic fields up to 799.99 gauss. The thin sensor is at the end of a 100 cm flexible cable. The sensor tip is also flexible and can be bent for a variety of situations. The sensor can be held against the surface of a steel part to check for residual magnetism, or it can be bent into an "L" shape to measure inside a DC Solenoid. This meter has a resolution of .01 gauss (1/50 of the Earth's typical field) which is finer resolution than the Model GM1-ST. It is also used to map fields from large magnets (If fields are over 800 gauss, use the Model GM1-ST). The meter has immediate turn-on and updates 4 times a second. There is no setup required, making this the fastest gaussmeter available.

  • Bench/System Precision Linear Regulated DC Power Supply With Digital Control, Single Or Triple Outputs, 105 To 242 Watts, With/without Remote Interfaces

    QL Series II - Aim-TTi

    Advanced dc power supplies, single or triple outputUp to 112 watts per outputVery high precision, very low noise, excellent dynamicsAdvanced user interface with numeric and rotary controlMultiple voltage/current ranges for increased flexibilityMultiple non-volatile memories for power supply set-upsSwitchable remote sense provides perfect load regulationComprehensive protection including OVP and OCP tripsCompact bench footprint; modular width for rack mountingAuxiliary output fully variable 1.00V to 6.00V at 3A with selectable voltage and current metering (T models)Bus programmable via USB, RS232, GPIB or LAN (P models)LAN interface is LXI compliantDuplicate power and sense terminals at rear (P models)

  • Scalar Feed Horn Antennas

    ERAVANT

    Scalar feed horns are offered as both standard and custom build models with either a circular or rectangular waveguide interface. While scalar feed horns with a rectangular waveguide interface can only support linear polarization, models with a circular waveguide interface can support various polarization types including horizontal, vertical, left-handed circular, and right-handed circular polarization for broader applications. The standard models operate across the full waveguide band and offer 17 dBi nominal gain, 25 degrees half power beamwidth and a -28 dB side lobe level at center frequency. The below standard offering covers the frequency range of 8.5 to 140 GHz. However, other frequencies or gain values are also available.

  • Dual Polarized Antennas

    ERAVANT

    Dual polarized horn antennas are offered as both standard and custom models with rectangular waveguide interfaces for both horizontal and vertical ports. These dual polarized horn antennas support both linear and elliptical polarized waveforms. When the antenna receives a circular polarized waveform, equal amplitude linear polarized waveforms are output at both horizontal and vertical ports. When two equal amplitude linear polarized waveforms are input into the vertical and horizontal ports, the antenna will transmit a circular polarized waveform. The listed models offer 15 dB nominal gain and 33/28 degrees typical half power beamwidth at the center frequency of the band. They also exhibit 40 dB typical port isolation and 35 dB nominal cross polarization. These antennas cover full waveguide bandwidths within the frequency range of 8.2 to 110 GHz. In addition to the models listed below, models with 10, 20, 23 and 25 dB gain and other frequency bands are also available.

  • Fail Safe Waveguide Switches

    The Rotation Link SAS

    Waveguide switches enable very rapid switching between two RF channels. Fail Safe Waveguide Switches return to the de-energized position when the power is disconnected and requires a small holding current in the energized position. All models have low VSWR and high power handling capacity. They withstand the full power rating of the waveguide and most models can be pressurized to 0.2 MPa (2 ATO) for high peak power applications.

  • High Speed End Launch Connectors

    Fairview Microwave Inc.

    Fairview Microwave’s high-speed end launch connectors are comprised of four models that provide VSWR as low as 1.10:1 and a maximum operating frequency of 40 to 110 GHz, depending on the model. These end launch connectors are reusable, don’t require any soldering and have a compact profile with a 0.350-inch mounting width and a 0.005-inch launch pin. They feature an outer conductor made of stainless steel and a gold-plated beryllium copper center contact.

  • Single Channel Transmitter

    1066 - Barben Analytical

    The model 1066 Single Channel Transmitter is a loop powered device that can accept input from pH/ORP, conductivity (contacting and toroidal), and amperometric (dissolved oxygen, chlorine, and ozone) sensors.The model 1066 Single Channel Transmitter can display a liquid analytical measurement, in addition to a temperature measurement, current output, and diagnostic information. The transmitter has quick start programming for shorter installation times and an intuitive user interface for easy operation.

  • Digital Sound Meter

    SM-100 - Dwyer Instruments Inc.

    Model SM-100 Digital Sound Meter is ideal for measuring noise levels from 30 to 130 dB with accuracy of ±1.5 dB. Model SM-100 has a frequency of 31.5 Hz to 8 kHz, three different dB ranges, and a 1/2" condenser microphone. The SM-100 has two frequency weightings: the "A" weighting ranges from 30 to 130 dB, while the °C" weighting ranges from 35 to 130 dB.

  • Analog Output Board with Arbitrary Waveform Generation

    104-DA12-8A - Acces I/O Products, Inc.

    Model 104-DA12-8A is a PC104 board featuring eight independent 12-bit digital-to-analog converters (DACs) and broadly configurable arbitrary waveform generation (ARB) capabilities. Other convenient features include 128K SRAM for waveform data storage, eight 4-20mA current sinks, three 16-bit counter/timers and fused general-purpose +5V and +12V power outputs. An economy version is available without the ARB feature as model 104-DA12-8.

  • Dual Trace Analog Oscilloscope With Probes

    2120C - B&K Precision Corporation

    B&K Precision's model 2120C is a dual trace oscilloscope that offers high performance at a low price. Most competitor's entry level oscilloscopes have a 20 MHz bandwidth, while B&K Precision's models 2120C has a bandwidth of 30 MHz. This oscilloscope is built by and backed by B&K Precision, a company that has been selling reliable, durable, value priced test instruments for over 60 years.

  • Module For High Q-factor Structures Analysis.

    QProny - QWED Sp. z o.o.

    In order to assist the users of QW-3D in the analysis of high Q structures, a special software module QProny, co-authored by Prof. M. Mrozowski was developed. QProny uses one of the most robust signal processing techniques known as the Generalised Pencil of Function Method (GPOF) and employs unique and innovative methods for automatic selection of the most important parameters such as:• the number of initial samples to be skipped• the number of samples required for model construction• the model order

  • Test Kit

    Metriso B530 - Wolfgang Warmbier GmbH & Co. KG

    Test voltage / Test current: 1 mA < I < 1,3 mAHigh ohmic range: DC 10 volts,100 volts and 500 voltsTest range:low ohmic range: 1 to 10 kOhmhigh ohmic range: 1 kOhm to 199 GOhmOperation: Battery operatedProbes:2x Model 870 (weight: 2,27 kg / ø 63,5 mm) with conductive rubber (grey) and extension,1x hand-held probe Model 45

  • 600W Bench Electronic Load, Dual Input 150V, 60A, 300W

    EL34243A - Keysight Technologies

    Keysight’s EL30000 Series bench electronic loads consist ofthree models, all with a built-in data logger. The EL33133A basic performanceelectronic load offers an economical price, a limited range, and a single 40 A,150 V, and 250 W input. Two performance models offer additional ranges, theEL34143A single input 60 A, 150 V, 350 W, and EL34243A dual input 60A, 150V,600 W.

Get Help