  • DC Gaussmeter

    GM1-ST - Alpha Lab, Inc.

    The Model 1-ST measures strength and polarity of magnetic fields up to 19,999.9 gauss. The sensor can easily fit in a .060 inch (1.5 mm) gap and is at the end of a 100 cm flexible cable. The sensor end can be bent if required for a variety of situations. Place the sensor on a magnet face to measure the field. With a resolution of 0.1 gauss, it can measure any tiny variation from magnet to magnet or it can detect if a given magnet has lost even a little strength. Bend the sensor in to a "L" to measure inside a DC solenoid tube. The 5 digit display requires neither auto nor manual range change, making it easier to use than older style 3 or 4 digit meters. Turn on the meter and immediately begin reading fields (updates 4 times per second). There is no setup required, making this the fastest, easiest gaussmeter available.

  • Digital Ior Leakage Current Clamp Tester

    MCL-400IR - MULTI MEASURING INSTRUMENTS Co., Ltd.

    About Ior Leakage Current Recently, the leakage current clamp meter is widely used for insulation control of low voltage circuit as the supplementary method of the insulation resistance measurement. The control of leakage current has the advantages to enable the prediction of insulation condition in the electrical power line without having to shut off the power. The leakage current (Io) includes the capacitive leakage current (Ioc)originated in the capacitance and the resistive leakage current (Ior) originated in the insulation resistance each related to the ground. It is considered that the measurement of resistive leakage current (Ior) is the very useful and effective method for the insulation control of low voltage circuit. However, it was difficult to measure the resistive leakage current (Ior)with traditional leakage current clamp meter. MCL-400IR new digital clamp tester enabled the measurements of the resistive leakage current (Ior)without voltage input(phase detection).

  • Intelligent Digital Multimeter, Calibrated, 3999 Count, Mean Value, Auto, Manual Range, 3.75 Digit

    72-7755 CAL D  - Tenma

    The 72-7755 CAL D from Tenma is an intelligent digital multimeter. It has auto range or manual range options and dual display with maximum reading 3,999 displayed in 40 analogue bars in scale making the measured value to be seen clearly and indicating the trend of changing quickly. In addition to conventional measuring functions, there is a new breakthrough in frequency test with maximum range of 400MHz. RS232C standard serial port is equipped with meter for easy connection with computer to realize macro recording and monitoring and capture of transient dynamic data, displaying change of waveform during measurement, providing data and evidence to engineering technicians for scientific research. This is also a highly applied digital multimeter of high performance with full input protection and display backlight. The orange and grey colour meter features 73mm × 50mm size LCD, CAT III 1000V and CAT IV 600V safety ratings.

  • Intelligent Digital Multimeter, Calibrated, 3999 Count, Mean Value, Auto, Manual Range, 3.75 Digit

    72-7755 CAL  - Tenma

    The 72-7755 CAL from Tenma is an intelligent digital multimeter. It has auto range or manual range options and dual display with maximum reading 3,999 displayed in 40 analogue bars in scale making the measured value to be seen clearly and indicating the trend of changing quickly. In addition to conventional measuring functions, there is a new breakthrough in frequency test with maximum range of 400MHz. RS232C standard serial port is equipped with meter for easy connection with computer to realize macro recording and monitoring and capture of transient dynamic data, displaying change of waveform during measurement, providing data and evidence to engineering technicians for scientific research. This is also a highly applied digital multimeter of high performance with full input protection and display backlight. The orange and grey colour meter features 73mm × 50mm size LCD, CAT III 1000V and CAT IV 600V safety ratings.

  • Intelligent Digital Multimeter, Calibrated, 3999 Count, Mean Value, Auto, Manual Range, 3.75 Digit

    72-7755 CAL DU - Tenma

    The 72-7755 CAL DU from Tenma is an intelligent digital multimeter. It has auto range or manual range options and dual display with maximum reading 3,999 displayed in 40 analogue bars in scale making the measured value to be seen clearly and indicating the trend of changing quickly. In addition to conventional measuring functions, there is a new breakthrough in frequency test with maximum range of 400MHz. RS232C standard serial port is equipped with meter for easy connection with computer to realize macro recording and monitoring and capture of transient dynamic data, displaying change of waveform during measurement, providing data and evidence to engineering technicians for scientific research. This is also a highly applied digital multimeter of high performance with full input protection and display backlight. The orange and grey colour meter features 73mm × 50mm size LCD, CAT III 1000V and CAT IV 600V safety ratings.

  • Multifunction Calibrator 15 ppm basic accuracy

    MC142 - Powertek LLC

    Multifunction calibrator MC142 is a precision voltage, current and power calibration source serving as a measurement standard in calibration laboratories and production lines; where verification of electrical measurement equipment & sensors is required. It can be used for calibration and adjustment of meters measuring voltage, current, power, resistance, capacitance and frequency. Internal harmonic and non-harmonic signals make it possible to test electrical performance of meters using signals with various crest factors. Frequency modes enable selection of frequency, amplitude and duty cycle of the output signal. These are suitable for basic calibration of digital and analog oscilloscopes along with transient recorders. The calibrator is equipped to measure temperature with TC and RTD temperature sensors. Its built-in multimeter can be used independently or simultaneously with the calibrator output. Testing of transducers of various types, regulators and sensors can be performed, without the necessity to use any other measuring instrument.

  • 10 MHz to 6 GHz/33 GHz LAN Power Sensor

    U2049XA - Keysight Technologies

    Wide dynamic range (-70 to +20 dBm) for small signal measurementsLAN/ Power-Over-Ethernet (PoE) connectivity for long distance remote monitoring (up to 100 meter)TVAC compliant for operation in vacuumBest-in-class long term drift performanceInternal zero and automatic calibration saves time and reduces measurement uncertaintyEasy measurement start-up with new intuitive BenchVue software

  • Electricity Metering Device- Transmission

    Mk11 - EDMI Ltd.

    The Genius Mk11 is a highly-precision smart meter designed for generation, transmission and large industrial markets. Surpassing the IEC Class 0.2S requirement, it offers the highest level of metering system accuracy and equip with full power quality features complying to IEC 61000-4-30. In addition, Mk11 also offers 12kV impulse protection and complies to Safety Standard IEC 62052-31.

  • Totalizer (pulse input)

    Laurel Electronics, Inc

    Two independent scalable pulse-input channels. Count up or down to a preset at rated up to 1 MHz. Scaled rate and total from the same electronic counter. Scaling for direct readout in engineering units, such as gallons or cubic feet based on counts from a turbine flow meter. One channel can display total while other displays rate.

  • Anemometers

    Beha-Amprobe

    If you want to keep your electrical equipment healthy and running, it is essential to monitor heating, ventilation, and air conditioning as well as the indoor air quality (HVAC/IAQ). Bioaerosols like dust mites and fungus, for example, can thrive in uncontrolled conditions and block HVAC ducts. Prevent your equipment from breaking down unnecessarily with an air flow meter from Beha-Amprobe.

  • 3 Digit LED Voltmeter

    SP 100 - Lascar Electronics Ltd

    The SP 100 is a 3 digit LED voltmeter with 9mm (0.36") digit height. It features 200mV d.c. full scale reading, auto-zero and auto-polarity. The meter plugs directly into two 6-way SIL sockets and can be fitted into a panel via the fixing clip. This module is directly compatible with competing products. Splashproof protection to IP65 is achieved by fitting the seal supplied

  • 4 band QRP CW transceiver

    MK2 - Youkits Technology

    QSK - full break- in60m band USB RXNew IC and hardware upgradedAssembed unit, tested and ready to use. 4 amateur band in one rig, no module needed.TX covering: 3.5-4MHz, 7.0-7.3MHz, 10.1-10.15MHz, 14.0-14.35MHzRX covering: 3.2-16MhzStep: 10Hz,100Hz,1KHz,100KHzOutput: 12V 3-4W, 13.8V 4-5WSidetone: 700HzDisplay: Frequency,mode,voltage,S meter,RIT

  • AC/ DC mA Current Clamp-on Transducer

    CA-60 - Tecpel Co., Ltd.

    This miniature clamp meter features two Hall effect sensors. For use with any multimeter with 200mV or/and 2V ranges for direct readout input impedance of least 1M ohm. High conversion factor for low DC and AC mA measurement. With the small jaw size it can fit into tight space in circuit panel or wire bundle to take the reading.

  • Auto-Analysis System Kit

    PGA-710 - Eurostat Group

    PGA-710 Auto-analysis Set• Auto-analysis Application Software Disk• PFM-711A Field Meter• CPM-720A Charge Plate Assembly• PCS-730 ± 1KV Charging Source• PHT-771 Digital Psychrometer• GAP-005 Ground Adapter Plug• PFA-861-H Handle• PWS-610M Fabric Band Wrist Strap• Carrying Case with Handle• Accessory Box• Operator’s and How to Measure Manuals

  • Automated Fibre Loss Test Set

    LTS-1500 - Scitec Instruments Ltd

    The LTS-1500 is a small, rugged automated fiber optic loss test set that characterises singlemode fiber links at wavelengths of 1310, 1490 and 1550 nm. It is comprised of a sensitive InGaAs based optical power meter calibrated at six wavelengths with better than -75 dBm noise level plus a stabilised laser light source with up to three selectable wavelengths.