Filter Results By:

Products

Applications

Manufacturers

Life

animate creation.

See Also: Life Cycle


Showing results: 946 - 960 of 1103 items found.

  • PXI Solid State Multiplexer, 30 Amp, Single 6-Channel

    40-667A-012 - Pickering Interfaces Ltd.

    The 40-667A-012 is a single 6-channel 30A MUX and is part of our range of high current multiplexers occupying two slots of PXI chassis. Each multiplexer switch uses a fully isolated solid state relay which has been designed to offer fast operation under hot switching conditions and high inrush current with no operational life degradation. Each multiplexer channel can support 10A of continuous current and switch up to 200V signals. The switches can sustain inrush currents in excess of 50A. AC or DC signals can be switched since the switch is polarity insensitive.

  • PXI Solid State Multiplexer Module, Single 6-Channel, 10 A

    40-666B-012 - Pickering Interfaces Ltd.

    The 40-666B-012 is a single 6-channel 10A MUX and is part of our range of high current multiplexers occupying two slots of PXI chassis. Each multiplexer switch uses a fully isolated solid state relay which has been designed to offer fast operation under hot switching conditions and high inrush current with no operational life degradation. Each multiplexer channel can support 10A of continuous current and switch up to 200V signals. The switches can sustain inrush currents in excess of 50A. AC or DC signals can be switched since the switch is polarity insensitive.

  • PXI Solid State Multiplexer Module, Dual 3-Channel, 30 A

    40-667C-011 - Pickering Interfaces Ltd.

    The 40-667C-011 is a dual 3-channel 30A MUX and is part of our range of high current multiplexers occupying two slots of PXI chassis. Each multiplexer switch uses a fully isolated solid state relay which has been designed to offer fast operation under hot switching conditions and high inrush current with no operational life degradation. Each multiplexer channel can support 10A of continuous current and switch up to 200V signals. The switches can sustain inrush currents in excess of 50A. AC or DC signals can be switched since the switch is polarity insensitive.

  • PXI Solid State Multiplexer, 30 Amp, Dual 3-Channel

    40-667A-011 - Pickering Interfaces Ltd.

    The 40-667A-011 is a dual 3-channel 30A MUX and is part of our range of high current multiplexers occupying two slots of PXI chassis. Each multiplexer switch uses a fully isolated solid state relay which has been designed to offer fast operation under hot switching conditions and high inrush current with no operational life degradation. Each multiplexer channel can support 10A of continuous current and switch up to 200V signals. The switches can sustain inrush currents in excess of 50A. AC or DC signals can be switched since the switch is polarity insensitive.

  • PXI Solid State Multiplexer Module, Single 6-Channel, 30 A

    40-667C-012 - Pickering Interfaces Ltd.

    The 40-667C-012 is a single 6-channel 30A MUX and is part of our range of high current multiplexers occupying two slots of PXI chassis. Each multiplexer switch uses a fully isolated solid state relay which has been designed to offer fast operation under hot switching conditions and high inrush current with no operational life degradation. Each multiplexer channel can support 10A of continuous current and switch up to 200V signals. The switches can sustain inrush currents in excess of 50A. AC or DC signals can be switched since the switch is polarity insensitive.

  • PXI Solid State Multiplexer, 10 Amp, Single 6-Channel

    40-666A-012 - Pickering Interfaces Ltd.

    The 40-666A-012 is a single 6-channel 10A MUX and is part of our range of high current multiplexers occupying two slots of PXI chassis. Each multiplexer switch uses a fully isolated solid state relay which has been designed to offer fast operation under hot switching conditions and high inrush current with no operational life degradation. Each multiplexer channel can support 10A of continuous current and switch up to 200V signals. The switches can sustain inrush currents in excess of 50A. AC or DC signals can be switched since the switch is polarity insensitive.

  • PXI Solid State Multiplexer Module, Dual 3-Channel, 10 A

    40-666B-011 - Pickering Interfaces Ltd.

    The 40-666B-011 is a dual 3-channel 10A MUX and is part of our range of high current multiplexers occupying two slots of PXI chassis. Each multiplexer switch uses a fully isolated solid state relay which has been designed to offer fast operation under hot switching conditions and high inrush current with no operational life degradation. Each multiplexer channel can support 10A of continuous current and switch up to 200V signals. The switches can sustain inrush currents in excess of 50A. AC or DC signals can be switched since the switch is polarity insensitive.

  • PXI Solid State Multiplexer, 10 Amp, Dual 3-Channel

    40-666A-011 - Pickering Interfaces Ltd.

    The 40-666A-011 is a dual 3-channel 10A MUX and is part of our range of high current multiplexers occupying two slots of PXI chassis. Each multiplexer switch uses a fully isolated solid state relay which has been designed to offer fast operation under hot switching conditions and high inrush current with no operational life degradation. Each multiplexer channel can support 10A of continuous current and switch up to 200V signals. The switches can sustain inrush currents in excess of 50A. AC or DC signals can be switched since the switch is polarity insensitive.

  • PXI Solid State Multiplexer, Dual 3-Channel, 30 Amp

    40-667B-011 - Pickering Interfaces Ltd.

    The 40-667B-011 is a dual 3-channel 30A MUX and is part of our range of high current multiplexers occupying two slots of PXI chassis. Each multiplexer switch uses a fully isolated solid state relay which has been designed to offer fast operation under hot switching conditions and high inrush current with no operational life degradation. Each multiplexer channel can support 10A of continuous current and switch up to 200V signals. The switches can sustain inrush currents in excess of 50A. AC or DC signals can be switched since the switch is polarity insensitive.

  • PXI Solid State Multiplexer, Single 6-Channel, 30 Amp

    40-667B-012 - Pickering Interfaces Ltd.

    The 40-667B-012 is a single 6-channel 30A MUX and is part of our range of high current multiplexers occupying two slots of PXI chassis. Each multiplexer switch uses a fully isolated solid state relay which has been designed to offer fast operation under hot switching conditions and high inrush current with no operational life degradation. Each multiplexer channel can support 10A of continuous current and switch up to 200V signals. The switches can sustain inrush currents in excess of 50A. AC or DC signals can be switched since the switch is polarity insensitive.

  • METES - Meter Test Systems

    KoCoS Messtechnik AG

    Dramatic advances in the field of measurement technology and the use of state-of-the-art micro-electronics have led to the development of a new generation of electricity meters which are far more accurate than their predecessors of just a few years ago. As well as measuring the exact amount of energy used, a high level of integration enables electronic meters to perform a number of additional functions. As a result, these meters are also more sensitive to network irregularities. This means that regular testing is the only way to ensure that a meter functions correctly, both during final factory tests and during the entire life span of a meter.

  • RF Shielded Test Enclosure, Largest Rack Mountable Enclosure

    JRE 1724 - JRE Test, LLC

    Originally designed for testing wide screen laptops, the rack-mountable JRE1724 is ideal for large wireless devices such as; Mesh Network AP's, Cellular/LTE/4G Base Stations, and other large RF devices. Featuring rugged welded aluminum construction, you can be assured of its tight RF shielding effectiveness. Long life door gasket material along with double edge engagement not only provides solid RF shielding, but smooth trouble free operation over its lifespan. Internal struts keep the lid open for easy internal access when connecting the device under test.

  • Brake Hydraulic Pressure and Electric Parking Brake Systems Test Bench

    Model BHP/EPB™ - MB Dynamics Inc.

    The new Model BHP/EPB™ Brake Hydraulic Pressure (BHP) and Electric Parking Brake (EPB) Systems test bench from MB Dynamics accurately measures and controls the hydraulic pressure and EPB power levels applied to brake calipers during automotive buzz, squeak and rattle (BSR) testing, as well as brake durability, stability, functional or performance testing. Varied brake pressures are applied according to timing diagrams, as well as automated or manually program-controlled repeat cycles, as required to assess brake caliper/rotor assembly noise, useful service life, and other critical performance metrics.

  • Ultrasonic Flaw Detectors

    Rinch Industrial Co.,Limited

    Application of ultrasonic flaw detector : It can not only be used in lab but also can be used on engineering site. Also, it can be widely used for safety checking and life evaluating in fields of aeronautics, rail transportation and boiler pressure vessel, it can used to test, orient, evaluate and diagnose various flaws such as crack, lard, air hole in work piece’s interior swiftly and accurately without any destruction. It is widely used for flaw detecting in fields of power engineering , boiler pressure vessel , Steel Construction , war industry , aeronautics , rail transportation ,auto and machinery etc. It is the essential flaw detecting instruments in NDT industry.

  • Ultra Low Noise, Rubidium Frequency Standard.

    A10-M - Quartzlock (UK) Ltd.

    Frequency Referencing, Calibration, Standards Lab, Production Test for Oscillator Manufacturers. A very high stability LOW NOISE 10MHz Rubidium Reference, primarily for production test of quartz oscillators and RF instrumentation frequency referencing. This industry standard 2U rack-mount instrument has a long heritage and ongoing production life for this latest 2009 version that features RS232 monitoring and control of the DPLL, locking the Ultra Low Noise OCXO to the Rubidium. Damping and Bandwidth is controlled by integrator digital gain, proportional digital gain, pre-filter order and subsample rate. Eight values of user selected bandwidth are available.

Get Help