Filter Results By:

Products

Applications

Manufacturers

Showing results: 211 - 225 of 277 items found.

  • EMC Testing

    D.L.S. Electronic Systems, Inc

    EMC testing and consulting services to the Electronics, Medical Equipment, Automotive, Aerospace, Computer, Telecommunications, and other industries. We are a NVLAP certified test facility, capable of testing electronic equipment to today's high frequency requirements. Our 14 Test chambers and 3 Open Area Test Sites can perform full scan Immunity and Emission testing at frequencies up to 40 GHz. Please contact us for your specific requirements.

  • EMC Testing

    Carl Zeiss AG

    Does your product send or receive electromagnetic data? This can be analyzed using various tests. We investigate the interference immunity and emitted interference of simple electrical devices and complex machinery. Our EMC measurements and tests conducted in accordance with standards recognize all activity in the electromagnetic field and ascertain how immune to interference a piece of equipment is. We will also offer guidance on optimizing the product in terms of its EMC properties during the development phase.

  • 24 TTL Channels, Enhanced, Programmable I/O

    TL2 - North Atlantic Industries

    Function module TL2 provides 24 channels of TTL/CMOS transceiver functionality as either inputs or outputs. The transistor-transistor logic (TTL) employs transmitters with multiple emitters in gates having more than one input. TTL offers high switching speed and relative immunity to noisy systems. CMOS sensors provide image sensing technology by converting light waves into signals that are small bursts of current. These waves can be light or other electromagnetic radiation.

  • 24 TTL Channels, Programmable I/O

    TL1 - North Atlantic Industries

    Function module TL1 provides 24 channels of TTL/CMOS transceiver functionality as either inputs or outputs. The transistor-transistor logic (TTL) employs transmitters with multiple emitters in gates having more than one input. TTL offers high switching speed and relative immunity to noisy systems. CMOS sensors provide image sensing technology by converting light waves into signals that are small bursts of current. These waves can be light or other electromagnetic radiation.

  • One Port Vector Network Analyser

    TE3001 - TrewMac Systems Pty Ltd

    The TE3001 One Port Vector Network Analyser is built for the professional who understands the calibration process and has a network analysis task to perform. The unit features a larger output signal than the TE3000 for better noise immunity, and is supplied with a 6 piece custom calibration kit to remove the effect of test fixtures and cables. Together, these features make the TE3001 ideal for broadcast and plasma applications that require a length of cable for connection and may be high in noise or interference.

  • Din Rail Load Cell Amplifier (user selectable gain)

    SY038 - Synectic Electronics

    The SY038 is a strain gauge bridge amplifier ideal for use in load cell amplification.  This Load Cell Amplifier has a variable gain functionality using a miniature dip switch which enables the user to select one of 16 ranges for transducer outputs as low as 0.25mV/V and up to 4.4mV/V, higher if specified.  It has the best stability in its class and high immunity to interference.  Non-interactive Zero and Span trimmers are screw driver adjustable giving a further +/-20% adjustment.

  • NI-9265, 4-Channel C Series Current Output Module

    779334-02 - NI

    4-Channel C Series Current Output Module - The NI‑9265 is ideal for interfacing and controlling industrial current-driven actuators at high rates. The module has built-in open-loop detection, which generates an interrupt in software when an open loop is detected as well as zeroing outputs to ensure safety and avoid driving actuators at system power on. The NI‑9265 requires an external power supply and includes a channel‑to‑earth ground double isolation barrier for safety and noise immunity.

  • sbRIO-9263 , Non-Enclosed, 100 kS/s/ch Simultaneous, ±10 V, 4-Channel C Series Voltage Output Module

    780876-01 - NI

    Non-Enclosed, 100 kS/s/ch Simultaneous, ±10 V, 4-Channel C Series Voltage Output Module - The sbRIO‑9263 is a simultaneously updating analog output module. It features overvoltage protection, short-circuit protection, low crosstalk, fast slew rate, high relative accuracy, and NIST‑traceable calibration. The sbRIO‑9263 module includes a channel‑to‑earth ground double isolation barrier for safety and noise immunity. Non-enclosed modules are designed for OEM applications.

  • NI-9215, cDAQ-9171, and NI-9981 USB Voltage Measurement Bundle

    865684-01 - NI

    NI-9215, cDAQ-9171, and NI-9981 USB Voltage Measurement Bundle - The USB Voltage Measurement Bundle with NI-9215, cDAQ-9171, and NI-9981 includes the NI-9215 C Series Voltage Input Module and the cDAQ-9171 CompactDAQ Chassis for voltage measurements. This bundle also includes the NI-9981 Connector for strain relief and operator protection from high-voltage signals. The included NI-9215 provides noise immunity, a high common-mode voltage range, NIST-traceable calibration, differential analog inputs, and four channels.

  • NI-9265, 4-Channel C Series Current Output Module

    779334-01 - NI

    4-Channel C Series Current Output Module - The NI‑9265 is ideal for interfacing and controlling industrial current-driven actuators at high rates. The module has built-in open-loop detection, which generates an interrupt in software when an open loop is detected as well as zeroing … outputs to ensure safety and avoid driving actuators at system power on. The NI‑9265 requires an external power supply and includes a channel‑to‑earth ground double isolation barrier for safety and noise immunity.

  • NI-9265, 4-Channel C Series Current Output Module

    783733-01 - NI

    4-Channel C Series Current Output Module - The NI‑9265 is ideal for interfacing and controlling industrial current-driven actuators at high rates. The module has built-in open-loop detection, which generates an interrupt in software when an open loop is detected as well as zeroing outputs to ensure safety and avoid driving actuators at system power on. The NI‑9265 requires an external power supply and includes a channel‑to‑earth ground double isolation barrier for safety and noise immunity.

  • C Series Voltage Input Module

    NI

    The C Series Voltage Input Module helps you work with voltage measurement applications. This module features isolation to separate channels from each other, from COM, or from earth ground for safety, noise immunity, and high common-mode voltage range. The module features up to 100 V of overvoltage protection for errant signal connection or unexpected outputs to the individual channels. You can use included options such as configurable input ranges, output channels, various connectors, and enclosed or non-enclosed modules.The C Series Voltage Input Module includes the NI-DAQmx driver and configuration utility that simplify configuration and measurements. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.

  • Infrared Motion Sensor

    ENVIROMUX-IMD - Network Technologies Inc

    Registers movement in the area covered. Condition display via LED. Provides immunity from common-mode signals such as the effect of strong hot or cold air currents, variation in ambient temperature, background radiation and acoustic noise. 24 dual-element detection zones for long, mid and short range protections. Surface or corner mounting. Pulse count or single shot triggering. Good RFI protection. Screw terminal. To connect to the RJ45 inputs use CAT5/5e/6 cable terminated at one end with RJ45 connector. Connect the un-terminated end to the sensor screw terminal. Maximum cable length: 1,000 ft (305 m). Powered by ENVIROMUX-2D/5D/16D. Includes mounting bracket for installing the sensor to a ceiling or wall. Regulatory approvals: CE, RoHS.

  • ESD Protection

    STMicroelectronics

    Protection against electrostatic discharges (ESD) is part of EMC Immunity (Electro Magnetic Compatibility) requirements. It is the ability for equipment to properly operate in its electromagnetic environment by limiting the reception of electromagnetic energy that may cause physical damage. ESD can be either conducted under the form of a transient voltage or can be radiated due to its fast rising time: powerful harmonics will generate erratic behavior by the application by coupling with other signals. Printed circuit boards must be protected against the effects of electrostatic discharge.

  • LETIS

    Laplace Instruments Ltd.

    Power amplifiers that are universally used for radiated immunity testing either cover the range below 1GHz or the range above 1GHz. This means that if the test requirement extends both sides of this 1GHz point, the power amplifier needs to be changed over. Genrally, this involves three connections... The LETIS handles all these connections automatically. Each is switched via a high performance RF relay under the control of a USB interface. Software issued with the Laplace Synthesisers automatically detects the presence of a LETIS and handles the switching automatically.

Get Help