Filter Results By:
Products
Applications
Manufacturers
- Pickering Interfaces Inc.
product
PXI Very High Density Mux Dual 10 Ch 8 Pole
40-670A-022-D/10/8
The 40-670A series of very high density multiplexer modules feature a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems.
-
product
Partial Discharge Measuring System
LDS-6
The Doble LDS-6 is a highly sophisticated digital measuring system for partial discharge detection and analysis. It is trusted as a valuable tool for factory and laboratory testing.The LDS-6 can be used to test a variety of high voltage apparatus. Use the LDS-6 to perform PD quality tests on motors, generators, transformers, MV and HV cable systems, switchgear and additional HV accessories.The LDS-6 complies with IEC 60270, VDE 0434 as well as various IEEE and other standards.
-
product
Extra-Ground Current Impuision Equipment
JYQ
Generally, the way of finding out the iron core ground false of powertransformer is always inefficient, while the method of using the traditional measure such as increase powerful current by welder when finding the false point oftransformer. The transformer needs to be mended on the spot or return to the factory if it can not melt off the point because of low voltage. It will spend high transportation fee and dealing costs, brings huge economic loss. The JYQ iron-coreimpulsionequipment is the intelligence set for exclusiveusing in solving the false of transformer. It can output high-voltage powerful current transientand melt the ground point off rapidly.
-
product
Adjustable Isolating Transformers
PeakTech Prüf- und Messtechnik GmbH
Is a 2 in 1 laboratory isolating transformer with integrated DC power supply, which was designed with the aspect of high safety requirements for use in research, science and repair. The device has a dual adjustable DC, AC output, which can also be used for constant voltage or current and offers high stability and performance.
-
product
Advanced Handheld Partial Discharge Detector for Electric Power Equipment with Multi-Sensor and Cloud Diagnostic Technologies, Data Management Software, and Test Management App
PDetector
Power Monitoring and Diagnostic Technology Ltd.
The PDetector is an ideal device for On-Line Partial Discharge (OLPD) testing of MV and HV equipment which employs all 5 types of OLPD sensor technology: Ultra-High Frequency (UHF), Acoustic Emissions (AE), Ultrasonic, High Frequency Current Transformer (HFCT), and Transient Earth Voltage (TEV). The information from multiple sensors gives the PDetector the versatility to detect all types of PD in all types of substation apparatus. The exact type of PD activity can be determined effectively using multiple on-screen data spectrum analysis. The PDetector greatly simplifies and standardizes the routine OLPD testing procedure by using the Intelligent Patrol function, the PDetector App, and the PMDTCloud. It is a very powerful and helpful tool for substation operators to conduct routine testing in a substation quickly, to determine what the issue is, and where it is located.
-
product
MIL-STD-1553 Test & Simulation Instrument for PXI
PXI-C1553
Avionics Interface Technologies
Dual redundant, single, dual or quad stream configurationsSoftware selectable Transformer, Direct, and Bus Stub Coupling Modes - Concurrent Bus Controller, 31 Remote Terminals, & Bus monitor operation - Full error injection and detection - Multi-level triggers for capture and filtering - Ten high voltage (up from 30V) programmable DIO lines - IRIG-B time code encoder/decoder with free-wheeling mode - Time Synchronization to PXI 10MHz reference clock - Real-Time recording and physical bus replay - PXI trigger generation on 1553 bus events - Initiate BC, RT Simulation and BM Capture on PXI Triggers - Application interface supporting C, C++, C#, and .NET development - Device driver support: Windows, Linux, LabVIEW Real-Time (others on request) - Compatible with AIT’s Flight Simulyzer GUI Bus Analyzer Software
-
product
High Impedance Transformers
Osborne high impedance transformers are used to step-up, step-down and isolate voltages in single phase and three phase circuits. A properly designed high impedance transformer can be used an an equivalent to an isolation transformer connected in series with an inductor. The high impedance characteristic may be employed as a current limiting feature in both the primary and secondary circuity.
-
product
High Voltage Test Set
Hi-Pot Series
SCOPE introduces a high voltage test set, these high voltage testing sets comes with Power frequency AC high voltage /DC high Voltage test /AC-DC high Voltage test set for testing transformers, motors, insulators, cables etc. Further, these testing sets are capable of giving continuously variable HIGH VOLTAGE from zero to maximum rated output voltage. Wide range of up to 100 kV is available in user selectable combinations.
-
product
HV AC Voltage Test Systems
Fivestar HV Testing Equipment Co., Ltd.
FSHV offers three different types of AC voltage test systems, the conventional type is AC test transformer design, mainly for testing objects of medium & low capacitance products, particularly for tests requiring stable voltage even if the load changes under voltage (corona, wet & pollution tests) or when the load is inductive (like inductive voltage transformers). Another is AC resonant test systems, according to series resonance circuit XL=XC (2πfL=1/2πfC), by setting F frequency of power supply or L inductance of reactor, generate a pure sinusoidal waveform of the test voltage, and the required input power is only 1/Q. Variable frequency type operates in a frequency range from 20Hz to 300Hz, ideal for field commissioning test of power cables and GIS/GIL. Variable inductance type outputs continuous AC voltage of power frequency (50/60Hz), mainly for factory testing of high and ultra-high voltage cables, power transformers, GIS, etc.
-
product
Transformer Turns Ratio Meter
TTRM 301
SCOPE introduces state of the art precision three phase Transformer Turns Ratio Meter (TTRM ) designed for field testing as well as factory testing of power transformers, instrument transformers and distribution transformers of all types. Along with turns ratio, this light weight and reliable instrument measures ratio deviation, phase angle deviation, magnetizing current and detects tap-position of single as well as three phase transformers in charged switchyard condition. The instrument has facility to automatically detect vector group of all majority configurations available. The differant AC voltage selection offers high accuracy in measurement.
-
product
Rapidox 6100 Pump Back Gas Analyser
The Rapidox SF6 6100 Pump Back is a fully-automatic zero-emissions SF6 gas analyser, designed for controlling and monitoring the quality and purity of gas used in high voltage switchgear, circuit breakers and transformers.
-
product
High Frequency Current Transformer
HFCT Ø 140mm
Techimp Clamp High Frequency Current Transformer model 140 is an inductive sensor for partial discharge measurements. It is suitable for online /off line PD tests on : large diameter cables ; grounding rod bar ; etc. A TNC termination is available to connect the Clamp HFCT 140 to the TechImp PD analyzer : PDCheck , PDBase etc. The arrow indicates the requested input current (Iin) direction to get coherent output voltage (Vout) polarity respect to ground. When the sensor is installed with the arrow directed to ground, the detected voltage signal (Vout) has the same phase of the input current (Iin).
-
product
Isolated LVDS
Isolated LVDS (low voltage differential signaling) devices couple differential signals applied to the LVDS receiver inputs across the isolation barrier to the outputs on the other side and re-transmits the bit stream or clock as LVDS. Analog Devices' drop-in LVDS isolators offer designers robust, high speed differential signaling for point-to-point and multidrop applications. Extending iCoupler® chip scale transformer technology for ultrahigh speed data encoding, these LVDS isolators support a a data rate of up to 2.5 Gigabits per channel for a total bandwidth of 10 Gbps. In contrast to expensive fiber implementations, deserialized links over standard digital isolators or optocouplers, and design-intensive bespoke solutions using transformers or high voltage capacitors, ADI Gigabit Digital LVDS isolators offer the only integrated comprehensive, high performance isolation at 10 Gbps. High performance galvanic isolation for applications include analog front-end (AFE), processor to processor serial communication, or video and imaging data (such as HDMI isolators) as well as isolation between boards, or at a cable interface for LVDS or CML signal chains.
-
product
Burn Down Transformer
ATG 6000
BAUR Prüf- und Messtechnik GmbH
Cable fault location with the BAUR ATG 6000. The high performance ATG 6000 burn down transformer is used for impedance reduction of cable faults in low- and medium-voltage networks. The short-circuit proof 5.75 kVA stray field transformer delivers a maximum voltage of 15 kV and is housed in a fully enclosed 19" housing.* Proven methodes for cable faults that are difficult to locate* Useful for cables that are difficult to access* Robust construction for reliable functions* Independent current and voltage control on each burning level
-
product
AC Resonant Test System
Yangzhou Power Electric Co., Ltd
Testing of certain apparatus requires much high voltage or current that a straight AC test system is not sufficient. Thus resonant test reactor with a variable core is needed. The main advantage of such test systems is lower input power and larger output power. The resonant test system is designed to compensate capacitance in the testing circuit precisely by tuning inductance of the test system. AC resonant test system is used for factory testing of middle, high and ultra-high voltage cables, capacitors, generators, motors, power transformers and gas-insulated switchgears.
-
product
TE-Metrology
HIGHVOLT Prüftechnik Dresden GmbH
The TE measurement complements the high voltage test and is part of the routine and type testing of numerous electrical devices. It is one of the most important non-destructive methods for detecting faults in electrical installations. The breakdown of an insulating material usually occurs at an internal weak point, which usually already shows a partial discharge activity in advance. For this reason, measuring partial discharges can help prevent costly damage. The TE measurement is thus used for quality testing and diagnosis in the factory as well as during on-site testing of cables, GIS, power transformers and transducers or rotating machinery and their components
-
product
Embedded Synchro - Resolver -
LVDT I/O Cards
Computer Conversions Corporation
100% Transformer Isolation is offered for all AC I/O, and various Isolated DC converters are available as standard product, eliminating concerns for ground-loops, ground interjected (intermittent and ghostly) field noise, inductive surges, differing potentials, and high voltage field transients from effecting the card itself, the sensitive ISA bus backplane and any other device or system sharing these signals.
-
product
1μΩ-4kΩ AC Milliohmmeter Low Resistance Tester
TH2521
Shenzhen Chuangxin Instruments Co., Ltd.
TH2521 AC Milliohmmeter is a high-performance and intelligent tester widely used to test contact resistance, internal resistance and battery voltage. The application of constant current source with 1kHz frequency can greatly eliminate the potential error caused by thermoelectricity on DUT. This meter has the function to automatically detect contact failures on test cable. At the range of 30mΩ, basic R resolution can reach 1μΩ. It is applicable for transformer, inductance coil copper resistance, relay contact resistance, switch, connector contact resistance, wire resistance, PCB line and via reistance dan metal defect detection, etc. In the mean time, signals, such as HIGH, LOW, PASS, can be output through HANDLER interface, thus it is very convenient to be used in automatic production line.
-
product
Tap Adapter
Techimp Voltage Tap Adapter is gender changer which allows the user to connect to the test tap (sometimes called power factor tap) of high voltage transformer bushings.While keeping the test tap well below the safety voltage level required by the manufacturer, the Tap Adapter lets the user to drain high frequency PD signals for diagnostic assessment of insulating materials.A synchronization signal can be derived as well.It is suitable for both single shot as well as continuous PD monitoring.Although it must be customized on the basis of the shape and dimension of the test tap (to be provided by the Customer), many models are readily available for the most established transformer bushings. A list of the presently available models is reported below.Several thousands of hours of operation are a guarantee of reliability and accurate design.
-
product
Contact Resistance Tester
JYL-200B/100B
Product description: JYL-200B/100B contact resistance tester can measure contact resistance of high voltage switches and circuit breakeres, also can test primar side resistance of transformer and grounding wire in groups
-
product
Partial Discharge Tester
GTPD-4C
GTPD-4C partial discharge comprehensive tester is the new generation of digital PD measurement and analysis instrument. The instrument has a strong ability of comprehensive analysis of partial discharge and detection of partial discharge in small signal and strong interference environment. With different accessories, it can measure and locate the partial discharge in any high voltage electrical equipment. It can realize testing the transformer partial discharge by applying the voltage on the three phases simultaneously.
-
product
AC / DC Combined High Voltage Test Set
Cambridge Instruments & Engineering Co.
suitable to perform AC High Voltage Power Frequency test on transformers, motors, cables etc. Leakage current can be measured at desired pressure and this set can be used as a source for cable fault burning.
-
product
Injection Transformer
J2100A
The injection transformer is presently the prevalent method for connecting the network analyzer to the circuit being tested, and is primarily used for control loop stability measurements. The goal of the transformer is to inject a signal into the control loop being measured, without impacting the performance of the loop. In order to accomplish this to a reasonable degree, The transformer is isolated and therefore is capable of floating on a high voltage, such as a Power Factor Corrector (PFC), which is often close to 400VDC. Measuring voltages that exceed the voltage rating of the FRA inputs require attenuation probes.
-
product
High Quality Transformer Oil Dielectric Strength Tester
AS-023A
Chongqing Assen Power Equipment Co., Ltd
AS-023A Series High Quality Intelligent Transformer Oil Dielectric Strength Tester is specially designed for testing dielectric strength (Breakdown Voltage) of transformer oil. The breakdown voltage (dielectric strength) is one of the most important parameters of transformer oil, it is a rule of the voltage withstand. The value of breakdown voltage (dielectric strength) indicates whether the oil contains water, impurity and electric particles, and you’ll know the oil value via the breakdown voltage (dielectric strength).
-
product
Test Sets For Diagnostic Testing
Test Sets For Diagnostic Testing are designed to test Oil Resistivity, Tan Delta, High Voltage Surge Comparison, etc. These test sets are automated instruments used to measure electrical features to insulate transformer oil, liquids and varied other insulating materials. They are ideal for revealing different localized problems and varied weak spots in the insulation. These modern testing sets are designed to provide high accuracy in results. In addition to this, they are easy to maintain testing sets available to ensure accurate readings.
-
product
MIL-STD-1553 Test & Simulation Interface for PCI
PCI-C1553
Avionics Interface Technologies
Dual redundant, single, dual or quad stream configurationsSoftware selectable Transformer, Direct, and Bus Stub Coupling Modes - Concurrent Bus Controller, 31 Remote Terminals, & Bus monitor operation - Full error injection and detection - Multi-level triggers for capture and filtering - Ten high voltage (up from 30V) programmable DIO lines - IRIG-B time code encoder/decoder with free-wheeling mode - Real-Time recording and physical bus replay - PCI & PCIx Compatible, 3.3V and 5V OperationApplication interface supporting C, C++, C#, and .NET development - Device driver support: Windows, Linux, LabVIEW Real-Time (others on request) - Compatible with AIT’s Flight Simulyzer GUI Bus Analyzer Software
-
product
Electric Transformer
Zhengzhou SMS Electric Co.,Ltd
For the convenience of the user or the low voltage metering box of electric energy metering, instrument with high precision (0.1)split core type current transformer.
-
product
High Voltage Transformers
We, NMC, are engaged in manufacturing AC/DC High Voltage Transformers ranging from 5kv upto 150Kv having current capacity from 10mA to 200mA AC/DC in Air cooled or Oil Cooled type as per the customer requirement.
-
product
DC Power Supply
◎PW-4063R
*Use Toroidal Transformer. Low EMI & High EMS.*Triple output, 0-32V/0-6A X2 and 5V/3A .Max. 400Watts*Tracking operation. Max. output 64V/6A on tracking series or 32V/12A on tracking parallel.*4 display, Green LED shows Voltage and Red LRD shows Current. Easy to read.*Compact design. G.W. 9Kgs only. Easy to handle.*The resolution of PW-4063R as high as 0.01v and 0.001A.*Provide 4Pcs 10turns micro adjust VR for Voltage and Current adjustment. Easy to operate.*Very low Ripple & Noise, less than 0.4mVrms. Very suit for precise measurement.
-
product
Handheld Turns Ratio & Winding Resistance Tester
TWR-H Series
Handheld TWR-H device is DV Power single-phase instrument designed for measuring transformer winding resistance and turns ratio.The instrument has two output DC sources for measuring transformer winding resistance. The first DC source can output up to 2 A DC and is used for injecting current to the transformer’s high voltage winding. The second DC source can output up to 10 A DC and is used for testing the transformer’s low voltage winding. This is especially useful when measuring winding resistance of distribution transformers. These transformers have large turns ratio and therefore a big difference between resistances of high voltage and low voltage windings. Upon the winding resistance test, it is also possible to demagnetize the transformer core. The demagnetization process is completely automatic and safe.Together with the turns ratio, the instrument also measures excitation current and phase shift. This enables detecting transformer core or winding turns failures which cannot be spotted by measuring turns ratio only. The instrument can output test voltage up to 40 V AC for this test, but it can also output a very low test voltage of 1 V AC which is necessary for turns ratio verification of the majority of current transformers.TWR-H is powered by an internal Li-Ion battery. Up to 100 tests can be performed with a fully charged battery.
-
product
Load Cell Power Supply
MODEL PSMR
The PSM-R is a self contained AC power bridge excitation supply. This device consists of a low interwinding capacitance AC transformer and a high stability adjustable linear regulator designed specifically for driving transducer bridges. DC excitation is adjustable from 4 to 15 volts output and is capable of supplying 0 to 150 mA in output current. It features remote sensing to eliminate line drop errors and very low noise. It can also be used as a high quality voltage source or reference in many applications. AC input requirements are 105 to 125 VAC at 60 Hz.