- Pickering Interfaces Inc.
product
LXI High Density 16x64 2A Matrix with BIRST
60-552-021
It is constructed from 8x64 sub-assemblies, permitting the matrix to be supplied in a variety of sizes from a single 16 x 64 to 64 X 64 and dual 8x64 to 32x64. Larger configurations can be easily achieved by utilizing the Loop thru connections on either the X or Y bus, for instance, four 64x64 units can be linked to create a 128x128 matrix.
-
product
Standard 4.47 (127.00) - 12.00 (340.00) High Frequency Probe
K-50B-S
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 2.50Nominal Impedance (Ohms): 50Test Center (mil): 600Test Center (mm): 15.24Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 90Recommended Travel (mm): 2.29Overall Length (mil): 1,205Overall Length (mm): 30.61
-
product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50B-QG-75
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,575Overall Length (mm): 40.00
-
product
Vector Network Analyzer Extenders
VNAX
VDI''s VNA Extenders deliver high performance network analyzer frequency extension into the THz range. Models cover 50 GHz to 1,100GHz with additional bands in development. VDI modules come in a variety of form factors and configurations including our original Standard-size Modules and new Mini Modules that reduce volume up to 75%. In addition to our full Transceiver (TxRx) modules, VDI also offers Transmit-Reference (TxRef) modules and Receive only (Rx) modules that deliver optimized performanc...show more -
product
500 MHz Passive Probe, 5mm, 10:1, 10 MOhm
PP026-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscillosco...show more -
product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50B-QG-75R
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,637Overall Length (mm): 41.58
-
product
Vector Impedance Analyser
TE3000
The TE3000 Vector Impedance Analyser is a portable desktop instrument designed for high accuracy impedance measurement. The probe style construction and small output signal make it ideal for "in circuit" impedance characterisation of small signal devices without the risk of damage to the device under test. The TE3000 comes factory calibrated to the tip of the probe with optional custom calibration. Turn it on, set the frequency, take a measurement, and display the results in any format.
-
product
Microtester Test Systems
With the micro probes and the fine-pitch adapters used on them, you are able to contact the finest test structures. E-tests, functional tests, IC tests or high-current tests are made to be affordable, efficient and with a short cycle time. With the integration of HF adapters we also enable the double-sided testing of HF substrates up to high frequency ranges.
-
product
250 MHz Passive Probe for WaveSurfer3000, 10:1, 10 MOhm
PP019-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscillosco...show more -
product
Ultra Low Noise Preamp
J2180A
The J2180A low noise preamplifier provides a fixed, AC coupled 20dB gain while converting a 1 MOhm input impedance to a 50 Ohm output impedance. With a 3dB bandwidth of 0.1Hz to 100MHz, the preamplifier improves the sensitivity of oscilloscopes, network analyzers and spectrum analyzers while reducing the effective noise floor and spurious response. The preamplifier can also serve as a low frequency DC blocker for a spectrum analyzer or you can use it to connect a high input impedance oscilloscope probe to 50 Ohm equipment.
-
product
DIGITAL TURNS TESTER AND DIGITAL LCRTZ METER
TURNS-LCRTZ
Digital TURNS TESTER with LCR for Counting / Measuring Number of Turns for Toroidal Coils , Current Sensor , Current Transformer , Round Core Coils. Can measure, Turns along with Winding Polarity , DC Resistance , Inductance (L), Capacitance (C), DC Resistance, Rac, Q, D, ESR and Tan.Toroidal Turns Platforms :TTPT100 : 5 T - 1000 T , TTPT1000 : 500T-10000 T The Platform has 2 connections for the coil and 2 for the probe wire. Measurement principle is based on dynamic comparison of the vo...show more -
product
MOD MONITOR
TYPE HFX-1
The Type HFX-1 Modulation Monitor is an ancillary piece of equipment, which is used with narrow bandwidth, or older oscilloscopes to allow viewing of RF signals and particularly modulated signals as high as 55MHz. The equipment contains an RF signal source and a broadband mixing circuit which converts the high frequency signal to an intermediate frequency within the oscilloscope’s range. The frequency control dial is simply adjusted until the RF signal is viewed on the scope. BNC connectors are ...show more -
product
Transmission Line Probes
Transmission line probes are a special type of passive probe designed for use at very high frequencies. They replace the high impedance probe cable found in a traditional passive probe with a precision transmission line, with a characteristic impedance that matches the oscilloscope input (50 Ohm). This greatly reduces the input capacitance to a fraction of a picofarad, minimizing the loading of high frequency signals. A matching network at the tip increases the DC input resistance. While they ha...show more -
product
10:1, 10 Mohm, 300 MHz Passive Probe
PP016
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscillosco...show more -
product
500 MHz Passive Probe, 2.5mm, 10:1, 10 MOhm
PP022-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscillosco...show more -
product
Active Differential Probe, 100 kHz to 12 GHz
U1818B
The Keysight U1818B 100 kHz to 12 GHz active differential probe makes it easy to perform high frequency in-circuit measurements using network, spectrum and signal source analyzers. With flat frequency response, low noise floor, and direct power from instrument connection, the U1818B allows measurements to be made while taking full advantage of Keysight's RF analyzers dynamic range.
-
product
Standard 1.59 (40.40) - 7.00 (198.50) High Frequency Probe
CSP-30TS-011
Nominal Impedance (Ohms): 50Current Capacity (Amps) @ 20° C: 1.00Bandwidth @ -1dB (GHz): 35.00Recommended Travel (mil): 67Recommended Travel (mm): 1.70Full Travel (mil): 100Full Travel (mm): 2.54Overall Length (mil): 1,003Overall Length (mm): 25.48Rec. Mounting Hole Size (mil): 213Rec. Mounting Hole Size (mm): 5.40Test Center (mil): 375Test Center (mm): 9.53
-
product
Specialist Test Probes
High Current Test Probes, Ultra-high Current Test Probes,Kelvin Test Probes, High Frequency Test Probes, Switching Test Probes
-
product
÷10, 500 MHz, 10 MΩ, Passive Probe
PP009-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscillosco...show more -
product
500 MHz Passive Probe, 2.5mm, 10:1, 10 MOhm
PP021-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.
-
product
Near Field Probes 1GHz - 10 GHz
SX set
The SX1 set consists of 3 passive near field probes for making measurements in the development phase of E-field and magnetic field with a high clock frequency in the range from 1 GHz to 10 GHz. The probe heads of the set SX allow for measurements close to electronic assemblies, e.g. on single IC pins, conducting paths, components and their connectors, to localize interference sources. Field orientation and field distribution on an electronic assembly can be detected through trained use of the ne...show more -
product
TightSight™ Clamp Meter, 660A AC/DC W/TRMS
61-765
*TightSight™ bottom display*Tapered jaws with hook tip*True RMS current and voltage*AC/DC voltage*Audible continuity*High frequency rejection**Peak hold*Max/min hold*Data hold*Selectable audible and visual alerts when potentially hazardous voltages are detected at the probe terminals*Selectable auto power off*Backlit display*Low battery indicator*Reads accurately on noisy electrical circuits
-
product
Low Voltage Single Ended Probes
A low voltage single-ended probe is typically used for measuring high-speed, ground referenced signals up to 12 V. These low voltage probes are the best choice for making measurements on high impedance, high frequency circuit elements which require minimal probe loading. Users should select probes with a low input capacitance specification (~1 pF) to minimize the probe’s loading effect on the circuit. A probe with lower input capacitance will offer higher input impedance at higher frequencies.
-
product
500 MHz Passive Probe for HDO4000, 10:1, 10 MOhm
PP018-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscillosco...show more -
product
RF High Frequency Probes
*Low impedance*High bandwidth up to 20 GHz*Repeatable measurements*Coaxial design*Interchangeable center conductor
-
product
500 MHz Passive Probe, 5mm, 10:1, 10 MOhm
PP025-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscillosco...show more -
product
Differential Probe
With signals becoming faster, and power supply voltages going lower, these active differential probes will allow floating measurements from 100uVolts to as high as 7000 volts. These probes provide high CMRR and a broad frequency range.
-
product
250 MHz Passive Probe for HDO4000, 10:1, 10 MOhm
PP017-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscillosco...show more -
product
Standard 0.80 (22.00) - 4.00 (114.00) High Frequency Probe
CSP-03G-003
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 3.70Return Loss @ -20dB (GHz): 1.80Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,090Overall Length (mm): 27.76
-
product
Cryogenic Millimeter-Wave / Microwave Test Fixtures and Calibration Kits
upj10
KEYCOM''s cryogenic millimeter-wave / microwave test fixtures and calibration kits are specifically optimized for testing the performance of patterns between the edges of printed boards(edge type) and circuit testing on the printed boards(probe type). They are also designed to minimize heat capacity by miniaturizing their dimensions so they cool off efficiently, and materials with low coefficient of linear thermal expansion such as invar are used for major parts where high dimensional stability is required. Their operating frequency ranges from DC to 110GHz.
-
product
TightSight™ Clamp Meter, 1000A AC/DC W/TRMS
61-775
*TightSight™ second display*Tapered jaws with hook tip*True RMS current and voltage*AC/DC voltage*Audible continuity*High frequency rejection**Peak hold*Max/min hold*Data hold*Selectable audible and visual alerts when potentially hazardous voltages are detected at the probe terminals*Selectable auto power off*Backlit display*Low battery indicator*Reads accurately on noisy electrical circuits