Showing results: 1 - 15 of 221 items found.
-
Model 2000AF & 2000SM -
OAI
The OAI Model 2000 Exposure Systems may be configured as either an edge-bead exposure system (2000SM) or a flood exposure system (2000AF); both configurations are based on OAI’s proven, time-tested platform.
-
sX series -
IT'IS Foundation
Exposure systems are equipment or systems designed for the assessment of, for example, health risk, efficacy of therapies or mechanisms associated with exposure to electromagnetic fields. The systems designed by the IT''IS Foundation are the sX series, where sX stands for "System for eXposure" with options for cells (c), vertebrates (v), and humans (h).
-
-
Model 2012AF & 2012SM -
OAI
The Model 2012AF Flood Exposure System provides a cost-effective method for automated flood exposure. Designed to accommodate wafers from 8” to 300mm, the tool features automated FOUP loading. Mask and substrate changeover can be accomplished quickly and easily adding to both versatility and high-volume throughput of this production tool.The Model 2012SM Automated Edge-bead Exposure System provides a cost-effective method for edge-bead removal using standard shadow mask technology. Designed to accommodate wafers from 8” to 300mm, the tool features automated FOUP loading. Mask and substrate changeover can be accomplished quickly and easily adding to both versatility and high-volume throughput of this production tool.
-
Castle Group Ltd.
EU Directives and the UK Regulations specify specific daily exposure limits, which can be translated into the HSE's Exposure Points. Points are determined quantifying the Vibration Level of tools and the Time that operators are exposed to the vibration, named Exposure Time.
-
OAI
UV Exposure Systems by OAI
-
-
sXcTEM835 -
IT'IS Foundation
Tests radiofrequency electromagnetic field exposures from mobile communication devices operating in the 900 MHz region (additional frequencies upon request). The setup is based on two Crawford TEM cells that are blindly excited by a fully computer-controlled signal unit.
-
OET -
PSE Instruments GmbH
A comprehensive analysis of PV modules includes many different parameters. Determining the normal module operating temperature (NMOT), incidence angle effects and comparing soiling effects on different modules up to the initial degradation of PV modules are all parameters that can be analyzed with our outdoor exposure tester. The tester comes with up to twelve electronic loads installed in a 19" rack. The loads have two main functions: maximum power point tracking (MPPT) and IV curve tracing. For the advanced analysis, it is possible to change between these two modes within one test. In the normal operation mode, the electronic load keeps the module under MPP and each predefined interval an IV curve is traced. The entire tester comes with all necessary sensors such as temperature sensor, which can be attached to the module to determine the NMOT temperature like defined in IEC 61215 (MQT 05) and IEC 61853-2. The irradiation sensor is also included. In combination with our tracking system P2, it is also possible to determine incident angle effects of the PV module. It is also possible to connect other irradiation sensors for diffuse and direct irradiation, which helps to understand the behavior of the module in different irradiation conditions. An optional albedo meter is a powerful tool for the analysis of bifacial modules. The entire graphical user interface is web based and offers the possibility to access the system from the all computers in the network.
-
-
Luzchem Research Inc.
Top irradiation is ideal for solids, paper and some biological samples; while side irradiation is usually preferred for liquids. Different wavelength ranges in the UV and visible regions are available from both broadband fluorescent lamps, LED lamps and xenon lamps. Fluorescent lamps are compatible with many Rayonet reactors including RPR-100, RPR-200 and RMR-600. Various configurations of photoreactors are available.
-
ELT-400 -
Narda Safety Test Solutions
*Wide frequency range (1 Hz - 400 kHz)*Standard-compliant measurement*Acceptance measurements compliant with CE standard IEC/EN 62233 and Generic Standard IEC 62311*Limit value traces conforming to ICNIRP 1998, 2010 and EMF Directive 2013/35/EU*Real time measurement with RMS and peak detectors*External FFT signal analysis for determining the frequency components via three channel analog output (one channel for each spatial axis) e.g. with the aid of a digital oscilloscope.
-
ABET Technologies, Inc.
Standard maintenance, lamp, or filter replacement, does not require any tools. Locking indicator dials on all the system controls, located together for ease of alignment, provide for a reproducible setup. A beam imaging accessory makes alignment even faster.
-
AFJ Instruments
Through different ways of coupling between luminaries and humans, a level of exposure of a person to electromagnetic fields can be derived. One part of the exposure is based on capacitive coupling between lighting equipment and person. This creates induced internal electric field that must be evaluated using an EMI receiver and a Van Der Hoofden test head.
-
National Technical Systems
Accelerated weathering is the simulation of the damaging effects of long term exposure of coatings, materials, and products to outdoor conditions. There are a number of different types of outdoor conditions accelerated weathering addresses, including wind, rain, icing, sand and dust, and of course, UV exposure.