Showing product results. 271 - 285 of 701 products found.
-
BIRD 210 - HGH USA
Testing detectors requires the implementation of ultra-low noise driving electronics and presenting high quality optical stimuli to the detector under test. This meets all these requirements and allows to test any type of detector by easily implementing the detector’s driving signals and providing exhaustive and accurate measurement results.
-
Pickering Interfaces Ltd.
Simulation of resistance based temperature sensors such as positive or negative temperature coefficient thermistors. Resistance Temperature Detectors (RTDs) can be wire-wound or thin film. Our RTD simulator modules provide a cost-effective method of simulating both PT100 and PT1000 RTD sensor types that require fine setting resolution.
-
Evident Scientific
Portable eddy current (EC) flaw detectors inspect metallic parts and perform highly reliable and advanced flaw detection of surface and near-surface defects. Olympus offers portable eddy current equipment to meet a broad range of applications, including the detection of surface or near-surface defects, and the inspection of bolt holes.
-
-
GAMMA-W - Amptek Inc.
Gamma-W software performs high-precision analysis of gamma-ray spectra from HPGe detectors, and is ideally combined with the PX5-HPGe and your high-purity germanium detector. It is noted for its accurate and reproducible analysis of small peaks even in the presence of high backgrounds. Gamma-W contains all of the options and algorithms legally required by many jurisdictions for quantitative analysis of HPGe gamma-ray spectra, including detection limit, radioactive decay control, uncertainties, documentation, etc…, and allows users to run samples from within the DPPMCA software.
-
ST60 TO-18 - Dexter Research Center, Inc.
A single-channel silicon-based thermopile provides lowest cost solutions in a small active area of 0.61mm x 0.61mm in a small TO-18 package. Time constant of 18ms with Nitrogen encapsulation gas. Delivers a very low Temperature Coefficient of Responsivity of -0.04%/C. This detector has a very short thermal shock response to ambient temperature change.
-
ST120 TO-5 - Dexter Research Center, Inc.
A single-channel silicon-based thermopile provides lowest cost solutions in a small active area of 1.2mm x 1.2mm in a TO-5 package. Time constant of 25ms with Nitrogen encapsulation gas. Delivers a very low Temperature Coefficient of Responsivity of -0.04%/C. This detector has a very short thermal shock response to ambient temperature change.
-
S25 TO-5 - Dexter Research Center, Inc.
A single-channel silicon-based thermopile that offers the smallest single element active area size at 0.25mm x 0.25mm in a TO-5 package. Delivers a fast 18ms time constant in Argon encapsulation gas and even faster with Neon gas at 9ms. Delivers a very low Temperature Coefficient of Responsivity of -0.04%/C.
-
M5 - Dexter Research Center, Inc.
A thin film-based thermopile offering very low noise and a small 0.5mm diameter active area in a TO-5 package. This is one of the lowest noise thermopiles you can buy and provides a time constant 28ms time constant with Argon encapsulation gas.
-
DR34 Compensated - Dexter Research Center, Inc.
A one-channel compensated thin-film thermopile in a TO-5 package. The active area and compensating element area are 3.16mm x 0.4mm each. Internal aperture minimizes channel-to-channel crosstalk and thus increasing sensitivity.
-
ST150 With Diffractive Lens - Dexter Research Center, Inc.
A single-channel silicon-based thermopile with integrated diffractive lens and internal baffle that delivers a very low Temperature Coefficient of Responsivity of -0.04%/C with a high output voltage, 19.5 FOV and a quick time constant of 38ms. This Low-cost detector comes in a TO-5 package and has a very short thermal shock response to ambient temperature change.
-
M34 - Dexter Research Center, Inc.
A thin-film thermopile in a TO-5 package with an active area of 3.16mm x 0.4mm that offers low noise output.
-
1SC Compensated - Dexter Research Center, Inc.
A thin film-based single channel thermopile detector that offers thermal compensation to minimize effects of sudden ambient temperature change during the initial five seconds of change. The 1SC Compensated comes in a TO-5 package with a medium sized 1.0 x 1.0mm active area. Compensation is achieved through the integration of two additional half-sized thermopile elements. Internal aperture is standard and precisely defines active area for applications with FOV and/or spot size requirements.
-
1M - Dexter Research Center, Inc.
A thin film-based thermopile with a 1.0mm diameter active area with good signal-to-noise ratio in a TO-5 package and a moderate time constant of 32ms with Argon encapsulation gas.
-
ST60 TO-5 - Dexter Research Center, Inc.
A single-channel silicon-based thermopile provides lowest cost solutions in a small active area of 0.61mm x 0.61mm in a TO-5 package. Time constant of 18ms with Nitrogen encapsulation gas. Delivers a very low Temperature Coefficient of Responsivity of -0.04%/C. This detector has a very short thermal shock response to ambient temperature change.