Showing results: 2761 - 2775 of 5316 items found.
-
RNT-5A -
Neutronics Manufacturing Co.
This is a portable testing kit in one unit, suitable for testing protective relay, over current relay, earth fault relay, protective device, circuit breaker, tripping coils etc.The set is designed for both laboratory and field use. TECHNICAL FEATURES: INPUT : 230 Volts, single phase, 50Hz. AC. OUTPUTS : : 1) Current Output: a) 0- 1Amp. At 6/60Volts. (Continuous duty). b) 0- 5 Amps. At 6/60 Volts. (Continuous duty). c) 0- 10 Amps. At 6/60 Volts. (Continuous duty). d) 0- 20 Amps. At 6 Volts. (for30 min. duty). e) 0- 50 Amps. At 6Volts. (For 10 min. duty). f) 0-100 Amps. At 6 volts. (For10 min. duty). g) 0-200 Amps at 6Volts. (For 30 sec. duty). Current output is continuously variable and the output is taken out through a multi range C.T. The secondary is connected to an ammeter scaled in 0 to 100%. Output current range 1Amp. To 20Amps. Are selected by current range selector switch with common output terminals and for other three ranges three brass terminals are provided of proper ratting. 2) AC Voltage Output: Continuously variable 0 -230V AC. Capacity- 240VA (Max). OR DC Voltage Output: Continuously Variable 0-240V DC. Capacity-240VA.(max). One change over switch should be provided for selection of Volt. Meter for AC or DC voltage output & either AC or Dc voltage should be available at a time. 3) Time Measurement: 0-9.999Secs. & 0-99.99Secs. in two ranges. Accuracy: 1% CURRENT CIRCUIT: Loading transformer: Double winding loading transformer of suitable burden to provided corresponding current output specified before. One change over switch in current ckt. To be provided for voltage selection i.e. selection of 10volt. Or 50volt. Measuring CT: Multi ratio wound primary current transformer Ratio : 1-5-10-20-50-100-200A/5A. Variable auto transformer: For smooth variation of current output at various ranges selected. Tripping circuit: The current output will be cutoff incase of any overload for the range 200A or even if the relay under test actuated.
-
-
LAB / HPL -
ET System Electronic GmbH
*Output from 5kW to 10kW*Output voltage up to 600V*Output current up to 500A*Dimensions: 19 "x 3 U x 620mm*Integrated load; voltage controlled*For 2-quadrant operation*Compact design*Low noise development for pleasant work in the immediate vicinity of the device
-
56-926 -
CTEK Power USA
The LITHIUM US is an advanced microprocessor controlled charger specially designed to recharge and maintain the cells of Lithium-Iron (LiFePO4) batteries - maximizing their performance and lifespan. With up to 4.3A of charge current available the LITHIUM US is extremely flexible and will charge LiFePO4 batteries from 5Ah to 60Ah and maintain up to 120Ah.
-
CPE 8th Brick Series -
Semiconductor Circuits, Inc.
An eighth-brick DC-DC converter that conforms to industry standard specifications. The converter operates over an input voltage range of 36 to 75 VDC, and provides a tightly regulated output voltage with an output current rating of 30 A. The output is fully isolated from the input and the converter meets Basic Insulation requirements.
-
HH2107A -
Colluck Company Limited
Basic Accuracy 1.0%. Large LCD display 2000 count, 21mm figure height. Manual Ranging at your choice (19 Range). High Voltage test up to AC 750V and DC 1000V. Higher Current test up to 10A. Resistance test up to 20MΩ
-
WMA-320 -
Falco Systems
The WMA-320 is a high voltage, wide bandwidth laboratory amplifier. Its high output voltage, current and wide bandwidth have been designed to serve the needs of a wide variety of high-tech experiments. The WMA-320 can be used for MEMS actuation, EO-modulators, PZT (piezo) positioners, ultrasonics, and many other applications.
-
HH2210 -
Colluck Company Limited
Auto Ranging High Voltage test up to 1000V DC and 750V AC. Higher Current test up to 20A AC/DC. Diode test and Transistor test. Continuity check with buzzer sound. Measure Resistance up to 30MΩWide. Frequency test range up to 300kHz
-
DFX-20 -
Lisun Electronics Inc.
• Working power: AC220V 50Hz • Normal load: Continuous adjustable from 0 to 280V • Electric current: 0~20A/Continuos adjustable cosφ: 0.3-0.96 under 16A; 0.6~0.96 more than 16A • Precision: 0.5 class, digital display • Counter: 0~999999 times, can be preset
-
Morris Products Inc.
AC Voltage: 10/50/250/500VDC Voltage: 2.5/10/50/250/500VDC Current: 500u/10m/250mAVoltage Multimeter Resistance: 2K/200K Ohms MaxBattery Test 1.5V & 9VOverload ProtectionPower Source: One AA (1.5V) BatteryVoltage Multimeter Dimensions: 2.5” X 4.0” X 1.25”Weight: 3.4 oz.
-
PM0825 -
Applied Test Resources
The PM0825 consists of 8 fully independent four-quadrant power sources capable of supplying up to ±20V. Two of the sources are capable of up to 500mA each, four more are capable of performing at low levels with ranges of 1uA and 100uA; the remaining two are mid range with current ranges of 1mA and 100mA.
-
EMIC Corporation
The principle of the eddy current is applied to measure the distance without contacting an object. This measuring method is widely used in the industry for detecting abnormal vibrations of rotating shafts or ironwork in a production in line. The highly accurate signal conditioning for providing the analog voltage being linearly proportional to displacement can be made easy.
-
Mors Smitt Group
The concept is based on the need to improve the performance of existing pilot wire protection schemes by increasing reliability & availability as well as adding an over current guard function. This can be achieved at considerably lower cost than the replacement of the existing proven protection relays & change over to a fibre optic communication channel.
-
HH2205B -
Colluck Company Limited
High Accuracy (Basic Accuracy 0.5%). 3-3/4 Jumbo LCD display 3260 count with symbolic signs and bargraph. Double Injection Casing. Auto Ranging High Voltage test up to 1000V DC and 750V TRMS AC. Higher Current test up to 20A AC/DC
-
AC-DC High Voltage Power Supplies -
Acopian Technical Company
Ideal for laboratory and instrumentation applications, these rack mounting supplies have the same output ratings and specifications as the modular supplies, but additionally feature calibrated ten-turn controls (with locking vernier dials) for precisely setting voltage and current. Voltmeter and ammeter are standard. An 8' long shielded output cable is included.