Showing results: 16 - 30 of 51 items found.
-
154 -
Elcometer Limited
Metric and Imperial values are on the same comb, 50 to 800μm on one side, 2 to 32mils on the other.
-
J2150A -
PICOTEST Corp.
The USB Harmonic Comb Injector is a fast, easy-to-use, ultra-portable signal generator for interrogating your PDN to identify noise sensitivities. Quickly identify power supply related issues. Multiple modes include time and frequency jitter. Wideband harmonic comb spans 1kHz-1GHz+. Great for clock power supply EMI spectrum testing.
-
COMBGEN6DIFF -
Ultraview Corporation
*Differential output - can also provide two separate single ended complementary outputs.*Pulse height of up to +4V peak into 50 ohms, on positive output*Pulse height of up to -4V peak into 50 ohms, on negative output*Rise time < 80pS, FWHM of approximately 120pS*Produces pulse on both edges of input clock, thereby doubling frequency.*Input clock may be sinewave from 50MHz to 2GHz or square wave from 5MHz to 2GHz, producing fundamental comb tooth energy from 10MHz to 4GHz.*Usable energy to >10GHz.*Can drive any load, including short, without damage.*Power Requirements: -12V @ 120mA and +24V @ 80mA
-
Furaxa, Inc.
*Differential output - can also provide single ended outputs, one with positive going pulse, the second with negative going pulse. * Pulse height adjustable +1 to +5V peak into 50 ohms, on positive output, with concurrent -1 to -5V peak on negative output * Produces differential pulse on positive edge of input clock * Input clock may be 20-100MHz sinewave or 0.5-100MHz square wave, producing comb to 4GHz. Usable energy to >10GHz. * Differential outputs are designed to drive matched 50 ohm loads, but can drive any load, including short, without damage. Has integral fan. * Power Requirements: -12V @ 120mA and +18V @ 90mA.
-
112AL -
Elcometer Limited
The Elcometer 112AL, being punched from aluminium, is not as accurate as precision formed stainless steel wet film combs and has a shorter lifespan.
-
Elcometer 115 -
Elcometer Limited
Four separate thickness ranges are available up to a maximum of 1,250μm or 50mils and are manufactured to an accuracy of ±5% of marked value or ±3µm (0.12mil), whichever is greater.
-
U9391M -
Keysight Technologies
U9391M comb generators were developed to provide precision phase calibration, for non-linear measurements using the PNA-X nonlinear vector network analyser (NVNA), referenced to the National Institute of Standards and Technology (NIST) standard. Additionally, the comb generators can be used to calibrate PNA and PNA-X network analyzers for phase and delay measurements of frequency converters without requiring reference or calibration mixers.
-
U9391C -
Keysight Technologies
The Keysight Technologies, Inc. U9391C comb generators were developed to provide precision phase calibration, for non-linear measurements using the PNA-X nonlinear vector network analyser (NVNA), referenced to the National Institute of Standards and Technology (NIST) standard. Additionally, the comb generators can be used to calibrate PNA and PNA-X network analyzers for phase and delay measurements of frequency converters without requiring reference or calibration mixers.
-
U9391F -
Keysight Technologies
The Keysight Technologies, Inc. U9391F comb generators were developed to provide precision phase calibration, for non-linear measurements using the PNA-X nonlinear vector network analyser (NVNA), referenced to the National Institute of Standards and Technology (NIST) standard. Additionally, the comb generators can be used to calibrate PNA and PNA-X network analyzers for phase and delay measurements of frequency converters without requiring reference or calibration mixers.
-
U9391G -
Keysight Technologies
The Keysight Technologies, Inc. U9391G comb generators were developed to provide precision phase calibration, for non-linear measurements using the PNA-X nonlinear vector network analyser (NVNA), referenced to the National Institute of Standards and Technology (NIST) standard. Additionally, the comb generators can be used to calibrate PNA and PNA-X network analyzers for phase and delay measurements of frequency converters without requiring reference or calibration mixers.
-
112 & 3236 -
Elcometer Limited
These hexagonal precision formed stainless steel wet film combs are long lasting, reusable and supplied in a range of thicknesses measuring up to 3,000μm (120mils).
-
3238 -
Elcometer Limited
Each comb has 24 measurement steps (teeth) providing a more accurate wet film thickness value.
-
PTR Messtechnik GmbH & Co. KG
Compact design - Connection points for bridge combs - Solder-free circuit board contact - Plug -in connectors for interchangeable modules, such as small relays
-
Menlo Systems Gmbh
We offer add-on products for Optical Frequency Combs and metrology applications. These include heterodyne photodetectors (BDU), and highly stable RF oscillators, just to name a few.
-
F215 -
SDL Atlas
To determine the tensile strength of natural fibers. Includes 1 pair clamps and spacer, torque vice and wrench, cutter, comb and tweezers. A 5mg x 0.01mg capacity balance is required but not included.