Filter Results By:

Products

Applications

Manufacturers

Coil

One or more spiral turns of a conductor.

See Also: Helmholtz Coils, Coil Turns, Rogowski, Impulse Winding Testers, Transformer, Inductor


Showing results: 406 - 420 of 427 items found.

  • Temperature Loop Control Setup

    ULP-27 - Unitech Scales And Measurements Pvt. Ltd

    Unitech’s Temperature Control Loop Setup is basically a PC based PID controller setup used for closed loop and open loop analysis of temperature process system. The setup comprises of RTD temperature Sensor. The water flows through the Rotameter and Process tank to which a heating coil is fitted. The heater is controlled by a Thirstier drive. The Thirstier drive is connected to PID controller. The manual control valve can control the water flow. The system is mounted on a tabletop model with all necessary Piping. Water at approx. 100 LPH has to be supplied to a system externally. The electronic panel comprises of ADC/DAC card with RS-232 interfaces.

  • 4 2/3 Digital Resistance Meter

    CS2-RS - Chuan Sheng Electronics Co., Ltd.

    CS2-RS Resistance Indicator has been designed with high accuracy measurement, display and communication of Ohm (2 wire) as like as Coil of motor or transformer.The meter supports Field Calibration function. It can be calibrated with sensor (Resistance) to meet machinery structure.We build flexible function as like as 3 bank (for multi-range scaling and set point) and 3 external control inputs meet to various testing equipment inquiry.They are also building in 4 Relay outputs, 3 External Control Inputs, 1 Analogue output and 1 RS485(Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission and communication for a wide range of machinery and testing equipments applications.

  • High Performance Polyphase Energy Metering AFE w/ Power Quality Analysis

    ADE9000 - Analog Devices Inc.

    The ADE9000 is a highly accurate, fully integrated energy-metering device. Interfacing with both current transformer (CT) and Rogowski coil sensors, the ADE9000 enables users to develop a three-phase metrology platform, which achieves high performance for Class 1 through Class 0.2 meters. Power quality features enable advanced meter designs with fast rms measurements and power quality level monitoring for EN50160 compliance. The ADE9000 integrates seven high performances ADC’s, a flexible DSP core. An integrated high-end reference ensures low drift over temperature with a combined drift of less than ±25 ppm/°C max for the whole channel including PGA and ADC.

  • Automatic Circuit Breaker Tester

    GDGK-306 - Chongqing Gold Mechanical & Electrical Equipment Co.,Ltd

    1) Test standard: IEC622712) Closing and opening time measurement of 12 channels3) Max difference of closing or opening time measurement of three phases4) C-O and O-C time measurement5) Rated operation sequence test6) Bounce time and frequency measurement of breaker closing7) Circuit breaker closing and opening speed measurement8) Travel-time, Coil current-time curve of circuit breaker operation measurement9) Travel and clearance of circuit breaker measurement10) Variable DC circuit breaker operation power supply11) Closing arc resistance value and connected time measurement12) Closing time and opening time of graphite circuit breaker measurement13) Print test results by internal micro printers

  • Circuit Breaker Tester

    GDGK-307 - Chongqing Gold Mechanical & Electrical Equipment Co.,Ltd

    1) Closing and opening time measurement of 12 channels2) Max difference of closing or opening time measurement of three phases3) C-O and O-C time measurement4) Rated operation sequence test5) Bounce time and frequency measurement of breaker closing6) Circuit breaker closing and opening speed measurement7) Travel-time, coil current-time curve of circuit breaker operation measurement8) Travel and clearance of circuit breaker measurement9) Variable DC circuit breaker operation power supply10) Closing arc resistance value and connected time measurement11) Closing time and opening time of graphite circuit breaker measurement12) Print test results by internal micro printers

  • Insulation Meters

    PCE Instruments

    Here you will find an insulation tester for a variety of ranges between 50 mega ohms and 2000 mega ohms. The portable manual insulation tester is used for determining insulation resistance, continuous current, alternating current and testing. With an insulation tester, measurements can be taken for different voltages, beginning with 100V up to 10,000V. Measurements meet the DIN VDE 0413 part 1 standard. The insulation tester comes with a test mechanism, clips, batteries and a carrying case. The insulation meter can be equipped for test laboratories if an optional DIN EN ISO is acquired.Measurement of insulation in cables and motor coils is vitally important for the prevention of accidents and damage to installations and is obligatory according to most codes of conduct.

  • Circuit Breaker Analyzers & Timers

    CAT Handheld Series - IBEKO Power AB

    When it’s not practical to use conventional robust circuit breaker analyzers, a handheld circuit breaker analyzer and timer may come handy. DV Power has developed a unique CAT Handheld series. It is specially designed for testing of circuit breakers with one break per phase. Their compact and ergonomic design can provide a wide range of features and reliable operations in low, medium and high-voltage substations or in industrial environments.CAT Handheld series consists of two models, CAT-P and CAT-H. Both of them have a large (5,7 in) colored touch screen display. Because of that, test results are visible in dark places as well as in bright sunlight.Powerful internal Li-Ion battery of the instruments can last up to 8 hours of testing without recharging.CAT Handheld series records:main contacts operating times,contact synchronization,sequence time,a resistance of pre-insertion resistors,open and close coil currents,main contacts bounce time,auxiliary contact time,DC Voltage.Multiple operations, such as Open-Close and Open-Close-Open, can be initiated by using a predefined delay time or by triggering signal from current clamps connected to circuit breaker coil.CAT-H is capable of performing a coil control, while this feature is optional at CAT-P instrument. In contrast to CAT-H, CAT-P instrument can execute “First Trip” test.Both instruments display numerical and graphical results. Because of that, a user can easily overlay up to 4 records in the graphical form and make a quick on-site analysis of potential defects.A user can download test results to a PC via Bluetooth interface for more detailed analysis using DV Win software.

  • PXIe-4340, PXI Displacement Input Module

    785068-01 - NI

    The PXI Displacement Input Module supports 4-, 5-, and 6-wire AC linear variable differential transformer (LVDT) and AC rotary variable differential transformer (RVDT) measurements. The module simultaneously samples each analog input and sets the excitation frequency and voltage for each channel independently. You can set different timing, triggering, and sampling modes for each channel independently. Diagnostic features include self-calibration, overcurrent detection, and open coil detection.The PXI Displacement Input Module includes the NI-DAQmx driver and configuration utility that simplify configuration and measurements. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.

  • 1μΩ-4kΩ AC Milliohmmeter Low Resistance Tester

    TH2521 - Shenzhen Chuangxin Instruments Co., Ltd.

    TH2521 AC Milliohmmeter is a high-performance and intelligent tester widely used to test contact resistance, internal resistance and battery voltage. The application of constant current source with 1kHz frequency can greatly eliminate the potential error caused by thermoelectricity on DUT. This meter has the function to automatically detect contact failures on test cable. At the range of 30mΩ, basic R resolution can reach 1μΩ. It is applicable for transformer, inductance coil copper resistance, relay contact resistance, switch, connector contact resistance, wire resistance, PCB line and via reistance dan metal defect detection, etc. In the mean time, signals, such as HIGH, LOW, PASS, can be output through HANDLER interface, thus it is very convenient to be used in automatic production line.

  • Amplifier, Switch and Test Box

    CLIOQC Model V - Audiomatica

    The QCBOX Model 5 is a non-conventional unit designed to fulfil actual and future needs of an electro-acoustical analyzer like the CLIO system. It is USB linked to a PC and can be configured, with dedicated software controls, to assist frequency response and impedance measurements or to perform DC measurements. Using it for frequency response measurements acts as 50W power amplifier to drive the speaker or network under test while routing one-of-four inputs to the analyzer as well the current sensing output. The four inputs are able to provide a phantom power supply both for Audiomatica or general purpose microphones (0-24 V range, software controlled). Impedance measurements can be done either switching the D.U.T.’s load across the analyzer’s input or using a dedicated output, ISENSE, thus allowing impedance measurements in constant voltage mode as well voice coil current distortion analysis. An internal ADC measures the DC current into the voice coil. Thanks to an internal software controlled voltage generator the speaker can be driven with a superimposed DC voltage (±20V), allowing for measurements of large signal parameters. Two ADC converters with a ±2.5 V and ±5 V are available at inputs 3 and 4 to measure the displacement with a laser sensor or any other DC signal. A dedicated digital input handles an external foot pedal switch (or TTL signal) to be connected and triggers QC operations. A 6 bit output – 5 bit input TTL digital port is available to interface the QCBOX and driving software with external hardware (like turntables for example).The QCBOX Model 5 finds use both in laboratory for R&D applications and in production lines setups.

  • Subsea Pipe Tracking System

    HydroPACT 660E - Teledyne Marine TSS

    ​With HydroPACT 660E Teledyne Marine brings the world’s smallest submarine, pulse induction pipe tracker to market. Built upon the already established, industry standard and world leading TSS HydroPACT 440 system, the HydroPACT 660E continues the legacy by bringing pipe tracking and UXO detection capabilities to small inspection and observation class ROVs, for applications that were previously only available on larger vehicles such as work class ROVs and trenchers.The HydroPACT 660E has a single 24 Vdc, small subsea electronic pod, dramatically reducing the installed footprint and payload of the system while maintaining an operating range of greater than 85% of that of the significantly larger HydroPACT 440 system. The coil array features an integrated cable for even greater reliability and is suitable for installation and operation on smaller Observation class ROVs.​

  • Spring Fatigue Testing Machine

    TPJ Series - Jinan Testing Equipment IE Corporation

    Model TPJ Series Mechanical Computer Control Spring Fatigue Testing Machine is mainly used for the fatigue properties of all kinds of coil springs, disc springs, shock absorbers, and seal springs etc. The Spring Fatigue Testing Machine consists of motor, reducer on the connecting cams to drive the connecting rod and make reciprocating motion achieve the compression fatigue movement. The Spring Fatigue Testing Machine is efficient without any pollution to the environment. Equipped with different accessories, the Spring Fatigue Testing Machine can test springs of different sizes. Adopting the single-chip machine control, the Spring Fatigue Testing Machine realizes auto stop function when it reaches the preset test times. The Spring Fatigue Testing System is widely used in quality controls for spring, shock absorber production, and relevant applications.

  • Inductive Sensors

    Bernstein AG

    In general, inductive proximity switches consist of four basic elements: a coil, an oscillator, a threshold switch and an output stage with short-circuit protection.The oscillator generates a high frequency, electromagnetic alternating field which is emitted from the active face of the coil.Eddy currents are induced in a metal object that enters this field. These eddy currents draw energy from both the electromagnetic field and from the oscillator which is consequently attenuated.The more energy taken the closer the metal object moves towards the active face. The threshold switch switches on the output stage at a defined attenuation value.In proximity switches with a DC voltage supply, this switch is designed as an NPN transistor which switches the connected load to the negative pole or as a PNP transistor which switches the load to the positive pole. The output stage is a thyristor or a triac in AC voltage switches.

  • Primary Current Injection Sets

    R.R.Transformers & Equipments

    Protective devices such as relays, overload Coils, Circuit breakers and CTS etc. must be checked regularly to ensure that they are always ready to operate correctly, Routine current injection testing will quickly detect faulty or incorrectly adjusted protection circuits / devices & will be possible to prevent serious damage to the system. Primary injection kit is designed to operate on single phase 230/240 volts AC 50 HZ to develop smooth & continuous test current as for loading, calibrating, and testing of CTS, Bimetal Relays, Protection Relays etc. The test set gives high current output at low cost and with inherent safety. The primary current injection testing checks all parts of the protection system by injecting current down the cable / bus bars. The application of the primary current injection sets is to ascertain the current carrying capacity of any Conductor, insulator, connector or calibration of CTS / Bi-metallic relays etc.

  • Vibrating Sample Magnetometers (VSM)

    7400-S Series - Lake Shore Cryotronics, Inc.

    Backed and supported by over 40 years of expertise in measurement technologies, Lake Shore’s fully integrated vibrating sample magnetometers (VSMs) are used to characterize the DC magnetic properties of materials as a function of magnetic field, temperature, and time. Available in three different variable gap electromagnet configurations providing fields up to 3.42 T, Lake Shore VSM systems are sensitive, low-noise floor electromagnet-based VSMs that feature a broad temperature range capability—4.2 K to 1,273 K (-269 °C to 1000 °C). These systems measure a wide range of sample types, making them ideal tools for the most demanding materials research applications as well as quality control of magnetic materials. An assortment of options, including low temperature cryostats, a high temperature oven, a single stage variable temperature assembly, vector coils, autorotation, and an MR probe expand the functionality of Lake Shore VSM systems.

Get Help