Filter Results By:

Products

Applications

Manufacturers

Showing results: 421 - 435 of 486 items found.

  • Handheld Digital Thickness Gauges

    HC-210 - Shenzhen Chuangxin Instruments Co., Ltd.

    HC series of coating thickness gauge is a portable thickness gauge with eddy current thickness method and electromagnetic thickness method. It can be used to quickly and accurately measure the thickness of coating or cladding material without damaging it. As an  essential instrument for professional material protection, this coating thickness gauge is widely used in manufacturing industry, metal processing industry, chemical industry and commodities inspection etc., both in the laboratory and in the engineering field. It can measure the thickness of nonmagnetic layer on magnetic metal substrate condition (such as steel, iron, alloy and hard magnetic steel, etc.) and the thickness of conductive layer on nonmagnetic metal substrate condition (such as rubber, paint, plastic, anodic oxidation film, etc.).

  • Digestion Systems

    Tecator line - FOSS A/S

    FOSS Tecator line Digestion systems are based on a digestion unit and a tube rack, allowing fully automated digestion for convenient, safe and flexible Kjeldahl analysis. Two way PC communication supports traceability and GLP. These versatile digestion systems are capable of handling eight, twenty or forty tubes in volumes of 100 ml, 250 ml or 400 ml dependent on chosen configuration. Parameters: Kjeldahl digestions, Chemical Oxygen Demand & other reflux chemistries, Trace metal analysis by AAS or ICP instruments. Sample types: Raw materials and finished products in Food, Feed, Agriculture and related matrices, Water & Wastewater and a wide range of industrial compounds.

  • Clora Online

    XOS

    Chlorine is often present in crude oils and the concentration can vary greatly depending on the origin. If not removed, Chlorine can react to form highly corrosive hydrochloric acid in areas such as crude tower overheads, leading to serious operational issues, economic loss and safety concerns. The need for a reliable online chlorine analyzer for refining process control is more important than ever. Clora Online complies with ASTM D7536 method, and delivers continuous chlorine analysis to monitor plant equipment corrosion. By monitoring desalted crude, a plant can optimize performance and immediately see impacts of crude changes (including organic chloride). Additionally, monitoring overhead water can provide the necessary feedback for chemical feed.

  • Hydrostatic Head Pressure Tester

    Sataton Instruments Technology CO., Ltd

    Hydrostatic head pressure tester is designed to determine the resistance to water penetration of materials by hydrostatic pressure method. By measuring the opposition to the passage of water through the tested specimen, the tester is to provide standard testing conditions for operator to note the test terminal point. The tester is primarily intended for ducks, tarpaulins, tentings, waterproof materials and other materials which are used for impermeable application, such as chemical protective clothing or medical protective clothing.

  • pHTestr® 50 Waterproof Pocket pH Tester,

    Premium 50 Series - OAKTON Instruments

    The Oakton pHTestr 50 has a replaceable double junction sensor for longer life, an expanded number of applications, and easy maintenance. Double-junction electrode sensor handles wastewater and solutions containing sulfides, heavy metals, and TRIS. Electrode sensor offers a clog-resistant Kynar® junction and a recessed, glass pH bulb to protect against breakage. Valox sensor housing resists most chemicals. The keypad clicks to confirm operation, and allows access to a variety of functions. Calibrate up to three pH points with the auto-buffer recognition at both USA and NIST standard buffers. Additional features include an automatic temperature compensation (ATC), hold function, auto-off function, self-diagnostic error messages, and a three-segment battery-life indicator.

  • pHTestr® 50 Waterproof Pocket pH Tester,

    OAKTON Instruments

    The Oakton pHTestr 50 has a replaceable double junction sensor for longer life, an expanded number of applications, and easy maintenance. Double-junction electrode sensor handles wastewater and solutions containing sulfides, heavy metals, and TRIS. Electrode sensor offers a clog-resistant Kynar® junction and a recessed, glass pH bulb to protect against breakage. Valox sensor housing resists most chemicals. The keypad clicks to confirm operation, and allows access to a variety of functions. Calibrate up to three pH points with the auto-buffer recognition at both USA and NIST standard buffers. Additional features include an automatic temperature compensation (ATC), hold function, auto-off function, self-diagnostic error messages, and a three-segment battery-life indicator.

  • Sensor Bodies

    optek

    The armature - assembled sensor body - is the central component of an inline photometer. We have already designed more than 1000 different sensor bodies and more than 50 types are always on stock. All optek inline sensor bodies are made from high quality materials and are machined with extreme precision. The quality-tested manufacturing tolerances allow optical path lengths of up to 1000 mm, for which the accuracy of the incoming and outgoing light beam is ensured by testing a laser-based coaxiality tolerance test to the reference axis. To cover a wide spectrum of different process conditions, optek sensor bodies can be manufactured from various materials (also for aggressive chemicals or with NACE MR 0175) and adapted with regards to:

  • Affordable ICP-OES Spectrometer

    Ultima Expert LT - HORIBA, Ltd.

    HORIBA Scientific develops and manufactures high performance ICP-OES spectrometers for more than 35 years.• The new Ultima Expert LT provides high performance at affordable price for laboratories with challenging samples.• Ultima Expert LT integrates high efficiency Jobin Yvon optical design capable to achieve optimal performance for a large variety of sample types and matrices.• Ultima Expert LT is driven by the powerful Analyst software featuring a large variety of analytical functionalities for tailored control and analysis.• The robustness of the Ultima Expert LT makes it ideal for applications common to mining, chemicals manufacture, salt production, wear metals in oil analysis, petrochemical and metallurgical production• Gain in performance with the Ultima Expert LT for your most challenging applications!

  • Magnetic Flaw Detector

    CJX-A - Mitech Co., LTD.

    multifunctional magnetic flaw detector absorbed the advantages of similar products at home and abroad. With small size, light weight, easy operation, multifunction in one unit. The detector can equip A, D, O three types of probes to realize the functions of magnetic clamp detection, electromagnetic yoke detection, ring detection. It is the necessary detector to do flaw testing, quality control, safety check, life evaluation in the fields of petrol, chemicals, metallurgy, shipbuilding, aviation, railway etc..

  • ICP-OES Analyzer

    SPECTRO ARCOS - SPECTRO Analytical Instruments GmbH

    The SPECTRO ARCOS ICP-OES excels in industrial and academic applications for the most advanced elemental analysis of metals, chemicals, petrochemicals, and other materials.Its unique new MultiView plasma interface option provides truly uncompromising axial-view and radial-view plasma observation in a single instrument. The periscope-free MultiView mechanism lets an operator literally "turn" a radial-view instrument into an axial-view device, or vice-versa, in 90 seconds or less. Visit the MultiView Q&A section in the ARCOS Resource Center for answers to frequently asked questions. Plasma power enters a whole new era with the system's innovative generator. This unique, compact and extremely rugged component is based on laterally diffused metal oxide semiconductor (LDMOS) technology. It delivers the highest plasma power available today, enabling previously impossible feats of analysis at the highest plasma loads.

  • Metals Analyser

    Vulcan - Oxford Instruments plc

    Vulcan is the fastest metals analyser available, taking just one second to measure metal alloys - that’s faster than any XRF (X-ray fluorescence) analyser or any other laser product on the market. In quality control and quality assurance this means that large inventories of incoming raw materials or finished parts can be checked very quickly. Large quantities of scrap metal can be sorted in scrapyards easily and fast. Vulcan offers high performance and guarantees very high accuracy and precision for its analysis results. For example, when analysing aluminium, it not only provides the commercial grade of aluminium but also its accurate chemical composition. As Vulcan is so simple to operate, possible user error has been significantly reduced if not almost completely eliminated, so the results obtained from analysis will be reliable and consistent.

  • Quizix Precision Pumps

    Chandler Engineering

    The variety of models within the Quizix line offers several key advantages. The wide range of flow rates, pressure configurations and available options allow Quizix pumps to meet virtually any experimental requirement from bench top to pilot scale. The ability of Quizix pumps to handle almost any slurry, paste, liquid or gas provides unique capability not found in other positive displacement pumps. Exceptional flow rate accuracy, combined with non-stop pulseless flow makes Quizix pumps ideal for applications involved with rock core analysis/reservoir engineering, oil and gas production enhancement studies, EOR/IOR, PVT, rock mechanics, catalyst or chemical feed stock addition for reactor feed/chemical synthesis and any fluid delivery application where critical fluid delivery or pressure control is required.

  • Handheld Raman Analyzer

    TacticID®-1064 - B&W Tek, Inc.

    The TacticID®-1064 is a field-ready handheld spectral analysis instrument designed for non-contact forensic analysis by safety personnel and first responders, including law enforcement personnel, bomb squads, customs and border patrol, hazmat technicians, and more. The TacticID®-1064 utilizes proven Raman spectroscopy, allowing users to get real-time actionable identification of unknown chemicals, explosives, narcotics, pharmaceutical drugs and many other substances while reducing operational uncertainty and response time. The TacticID®-1064 includes a comprehensive library of over 10,000 substances. In addition, users have flexibility to create their own libraries. By utilizing the 1064nm wavelength, the TacticID®-1064 avoids fluorescence, allowing users to get results in less than 1 minute even when working with tough street samples.

  • BET Flowing Gas Surface Area Analyzers

    SA-9600 Series - HORIBA, Ltd.

    The surface area of a material is, in many cases, as important as the chemical properties. As particle size decreases, surface area increases. Porosity of materials - from micropores to macropores - contribute even more to the total surface area. The interface at the surface is what defines how a solid reacts to other substances, be they gases, liquids, or solids.Surface area can impact shelf life, stability, dissolution and efficacy of pharmaceutical powders and tablets. Likewise, surface area can affect the rheological properties and hiding powers of pigments, paints, and coatings. It has a significant impact on the ability for materials like catalysts, adsorbents, filtration materials and air separation products to react in the designed application. Ceramics used in applications ranging from; dinner plates, to dental implants, to electronics, all are affected by surface area.

  • Automated Total Nitrosamine Analyser

    Ellutia Chromatography Solutions

    Nitrosamines are carcinogenic compounds that can be found and formed in many products.  This has been a particular issue in the pharmaceutical industry recently.  Traditional approaches to the analysis, such as by mass spec, have been challenging due to the low detection levels required, the possibility of false positives, or even missing.  This system takes a unique approach of using the combination of a chemical reaction targeting nitrosamine compounds, then detection by a detector with very high selectivity and sensitivity for nitro/nitroso compounds. Rather than speciating the various nitrosamines present, the system gives a single quantitative result down to 1 ppb for the total nitrosamine content. This means both volatile and non-volatile nitrosamines are measured at the same time. This process is automated to allow a high sample throughput.  This makes it ideal for screening a large number of samples rapidly.

Get Help