Showing results: 796 - 810 of 1906 items found.
-
YAV91CLR -
6TL Engineering
The YAV90CLR card allows the intensity and color test of LEDs, in an automatic, precise and cost-effective way. The card has a calibrated RGB light source as a tool for calibration of the 16 channels or for detecting dirt on the optical heads.
-
AMETEK Drexelbrook
Drexelbrook’s line of magnetostrictive level probes utilizes proven machine tool positioning accuracy combined with process compatible floats to offer liquid level, interface level and temperature measurements with no requirements for maintenance or calibration.
-
Mensor Corp.
Test pumps serve as pressure generators for the testing, adjustment and calibration of mechanical and electronic pressure measuring instruments through comparative measurements. These pressure tests can take place in the laboratory or workshop, or on site at the measuring point.
-
WIKA Alexander Wiegand SE & Co. KG
Test pumps serve as pressure generators for the testing, adjustment and calibration of mechanical and electronic pressure measuring instruments through comparative measurements. These pressure tests can take place in the laboratory or workshop, or on-site at the measuring location.
-
TS25 MKII -
Intelligent Charging
Rugged and reliable designed for busy maintenance workshops, the TS25 MKII charger is suitable for every industry where batteries are used. It features a software controlled self-calibration facility which amounts to zero downtime for calibration.
-
MS-159 -
Misum Systech Co., Ltd.
This equipment used for F/W writing, Calibration and function test. It inspect current, voltage protection mode, consumption current and cell balancing measurement to check the state of BMS and applied to the full inspection and mass production.
-
85523B -
Keysight Technologies
The operation of the CalPods is via VNA firmware, and the CalPod controller provides the control signals for operation of the CalPod calibration refresh modules. The CalPod controller interfaces with the PNA family and M937xA PXIe vector network analyzers.
-
LAQUA PC220 -
HORIBA, Ltd.
- Automatic pH calibration - up to 5 points (NIST, USA pH buffers) / up to 6 points (DIN pH buffers)- 0.01 pH resolution- Offset and average slope display- ORP calibration option- Automatic / manual temperature compensation and temperature calibration function- Automatic (up to 4 points) and manual (up to 5 points) conductivity calibration- Adjustable reference temperature and temperature coefficient- Adjustable cell constant and selectable measurement unit- Conductivity and total dissolved solids (TDS) conversion- Four (4) TDS calibration curves for wide range of applications: EN27888, Linear, 442, NaCl- Two (2) salinity calibration curves: NaCl, Seawater- With real-time clock and date/time stamp for GLP compliance- Auto log data; built-in memory can store up to 1000 data- Auto shut-off (programmable: up to 30 minutes)- Auto stable, auto hold, and real time measurement modes- Calibration alarm (programmable: up to 90 days)- Built-in electrode holder allows 2 electrodes to be attached - Monochrome LCD with white LED backlight: 50 x 50 mm- Phono jack output for connecting meter to computer via PC (USB) cable for data collection and to printer via printer (RS232) cable for printout - Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip- Powered by 2 x AA batteries- Packaged with electrodes and calibration solutions in carrying case- 3 years meter warranty
-
ThermoWorks
A single select button scrolls quickly between the 3 factory set calibration points for efficiency. Two models to choose from: 271-018 (0°F, 32°F, 212°F) and 271-019 (32°F, 212°F, 500°F). Each unit includes a 3-point UKAS Accredited Calibration Certificate so you know that you''re using a precision instrument. Also included is a 3 foot type K test lead for connecting up your type K meters. You get precision at an economic price. Simple and fast!
-
NevadaNanotech Systems, Inc.
NevadaNano’s Molecular Property Spectrometer™ (MPS™) Flammable Gas sensor is powering the next generation of combustible gas detection. The MPS delivers unprecedented reliability, accuracy, and worker safety by simultaneously detecting over a dozen of the most common combustible gases, including Hydrogen, Methane, Propane, Butane, and many more. We call this TrueLEL™. No other flammable gas sensor can accurately report 0-100% LEL across over a dozen different gases with just one factory calibration, the MPS never requires field calibration.
-
Hydrogen Series -
H2scan Corp.
The H2scan GRIDSCAN 5000 Hydrogen Sensor pairs a high performance ASIC to H2scan’s field-proven solid-state hydrogen sensor. This stand-alone sensor system has been designed to provide precision hydrogen measurement, at a lower cost for the high-volume OEM or utilities. No calibrations or maintenance is needed for up to 10 years, and the GRIDSCAN 5000 is the lowest cost by thousands to any other available hydrogen DGA system. H2scan is the only company in the industry that can state retail sales of over 15,000 sensor systems worldwide with no after sale calibrations performed since 2012.
-
40-262-102 -
Pickering Interfaces Ltd.
The 40-262 is a 3U PXI module range that supports 6 (in one slot), 12 or 18 (in two slots) channels of RTD simulation. Based on the 40-260 design principles the module can provide a setting resolution of <8mΩ (PT100) or <90mΩ (PT1000) and a resistance accuracy of better than 0.1% on all channels. Each simulation channel is able to provide a short or open circuit setting to simulate faulty wiring connections to a sensor. Calibration or verification of each resistor channel can be verified by using the calibration port connected to a high performance DMM and a supplied software package.
-
ESCP-BMS1 Sensor -
ES Systems
ESCP-BMS1 is an absolute, gauge or differential pressure sensor of ultra-high resolution with analog (0-3,3V), PWM, SPI or I2C interface. The output is fully calibrated, and temperature compensated based on the internal temperature sensor and the factory calibration coefficients which are stored in the embedded memory. The sensor is ready to be installed directly to the end system without further processing with medical, HVAC, industrial, commercial & automotive applications. The total error including repeatability, hysteresis, non-linearity, thermal offset and calibration error between 0°C and 60°C is better than 0.25% FS.
-
40-262-202 -
Pickering Interfaces Ltd.
The 40-262 is a 3U PXI module range that supports 6 (in one slot), 12 or 18 (in two slots) channels of RTD simulation. Based on the 40-260 design principles the module can provide a setting resolution of <8mΩ (PT100) or <90mΩ (PT1000) and a resistance accuracy of better than 0.1% on all channels. Each simulation channel is able to provide a short or open circuit setting to simulate faulty wiring connections to a sensor. Calibration or verification of each resistor channel can be verified by using the calibration port connected to a high performance DMM and a supplied software package.
-
40-262-002 -
Pickering Interfaces Ltd.
The 40-262 is a 3U PXI module range that supports 6 (in one slot), 12 or 18 (in two slots) channels of RTD simulation. Based on the 40-260 design principles the module can provide a setting resolution of <8mΩ (PT100) or <90mΩ (PT1000) and a resistance accuracy of better than 0.1% on all channels. Each simulation channel is able to provide a short or open circuit setting to simulate faulty wiring connections to a sensor. Calibration or verification of each resistor channel can be verified by using the calibration port connected to a high performance DMM and a supplied software package.