Calibration
maintains accuracy of test asset by correcting out of specification conditions.
See Also: Calibrators, Power Calibration, Display Calibration, Calibration Standards, Calibration Software, Calibration Services, Calibration References
-
product
NI-9213, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module
785185-02
16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module - The NI‑9213 is a high-density thermocouple input module that is designed for higher channel count systems. With this module, you can add thermocouples to mixed-signal test systems without taking up too many slots. The NI‑9213 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The NI‑9213 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range.
-
product
Computer Based Audio Component Test System
DATS V3
Rugged aluminum housing with detachable test leads and built-in precision calibration resistorTighter tolerances on internal components for more precise measurementsIncreased output capability means greater separation from the noise floor, resulting in more accurate measurementsDATS Linearity Test for comparing parameters and impedance plots at multiple drive levelsOptional under desk mounting brackets included to save desk spaceOnly 1" H x 2-1/2" W x 4-1/8" D for easy portability
-
product
Optical Displacement Measurement Systems
ODS Series
The optical displacement measurement systems of the ODS series are specially designed for measuring the ultrasonic vibration displacement at bond tools of wire & flip-chip die bonders. The systems are highly accurate and very easy to use. That makes it the perfect tool for displacement based calibration of ultrasonic bond machines.
-
product
GFS Primary Gravimetric Flow Standard
The GFS dynamic gravimetric mass flow calibration system allows users to maintain the accuracy and traceability of molblocs or other high precision devices using the same primary reference used by Fluke Calibration. GFS is a true mass flow reference suitable for use in premier measurement institutes who require the lowest measurement uncertainty.
-
product
Furnace Calibration
Tempsens Calibration Centre offers calibration of wide ranges of Furnaces at site and at our lab.
-
product
Shear Stress Sensors
DirectShear™
Micromachined floating element shear stress sensor that enables time-resolved, one-dimensional, direct shear stress measurements. Direct measurement of shear stress — no heat transfer calibration. Non-intrusive — minimal flow disturbance. Simultaneous mean and fluctuating shear stress measurements. High resolution, dynamic range and bandwidth. Highly accurate, quantitative measurements.
-
product
Optical Power Meter
PM203
The PM203 optical power meter can be used to measure the radiometric power in a beam of monochromatic or narrow band light. Using the internal calibration table the micro-processor controlled PM203 displays directly the optical power in Watts or dBm or the calibration wavelength.
-
product
PXI Strain/Bridge Input Module
PXI Strain/Bridge Input Modules feature up to eightchannels that support quarter-, half-, or full-bridge sensors at speeds up to 102.4kS/s. The modules provide increased accuracy, high data throughput, and a range of synchronization features. Optional features include remote sensing, internal bridge completion, and shunt calibration options per channel. PXI Strain/Bridge Input Modules are ideal for dynamic strain, load and pressure measurements, and test cell installations requiring accuracy and flexibility.
-
product
Ambient Temperature CalPod Module, 20 GHz
85530B
CalPods provide a new and unique way to quickly and easily refresh a network analyzer calibration, at the push of a button and without removing the DUT or re-connecting standards.
-
product
Smaet LDV III
A Laser Doppler Velocimeter (LDV) measures fluid velocity by utilizing coherence of laser light. It detects the Doppler shift frequency of the scattering light of particles in the fluid and calculates the velocity of the particles (fluid). With a LDV system, non-intrusive measurements without disturbing the measuring object, liquid or gas flow, are achieved. No calibration is necessary and reverse flow measurements at a high resolution is also possible. The LDV system provides the absolute value of the flow velocity with accuracy.
-
product
Hydrophone
TC4047
The TC4047 miniature hydrophone offers a useable frequency range from 1kHz to 170kHz. The hydrophone incorporates a high quality 20dB low-noise pre-amplifi er which provides optimal conditions for signal transmission. The high sensitivity provides excellent signal to noise ratio and immunity against induced cable noise. The hydrophone is omnidirectional up-to 100kHz and has uniform receiving characteristic from 1kHz to 100kHz. An insert calibration circuit enables remote testing of the hydrophon...show more -
product
NI-9217, 4-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module
779592-01
4-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9217 is a resistance temperature detector (RTD) input module. You can configure the NI‑9217 for two sample rate modes: high sample rate or high resolution. The NI‑9217 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9217 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
product
Light Source
UVM-SP-JW
Readouts of UV intensity and cumulative luminescence count are prompted either on the front panel or via the externally connected remote signal control. The UV intensity detection segment is intended to measure a specific intensity of light signals, while the cumulative luminescence count is designed to tally a cumulative count on all UV intensities measured, in conjunction with real-time calibration.
-
product
4 2/3 Digital Potentiometer Meter
CS2-PM
Chuan Sheng Electronics Co., Ltd.
CS2-PM Potentiometer Indicator has been designed with high accuracy measurement, display and communication of Ohm (3 wire) as like as Positioner.The meter supports Field Calibration function. It can be calibrated with sensor (Potentiometer) to meet machinery structure.They are also building in 4 Relay outputs, 3 External Control Inputs, 1 Analogue output and 1 RS485(Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission and communication for a wide range of machinery and testing equipments applications.
-
product
Calibration Solutions
Software
SPEKTRA Schwingungstechnik und Akustik GmbH Dresden
The CS18 software was created in close cooperation with the SPEKTRA Calibration laboratory accredited by DAkkS. It meets the demands of every efficiently operating calibration laboratory already in its basic configuration and can easily be adapted to the workflows of any company.
-
product
Software / Downloads
Pratt & Whitney Measurement Systems, Inc.
Powerful and resourceful, Pratt & Whitney's GageCal Software sets a new standard for user-friendly calibration and part measuring. By controlling the operation and facilitating data collection, GageCal increases total measurement productivity. GageCal is included with the following product lines: Labmaster Universal Model 175, 1000M, 1000A, BM175, BM1000M, BM1000A, Labmicrometer Model 900, 1600, External Supermicrometer Model PC, Universal Supermicrometer Model 501, 504. GageCal is an optional add-on for the External Supermicrometer Model C and Digital Measuring Machines.
-
product
Individual Precision Foils
Elcometer 990
Calibration foils or ‘shims’ are the most convenient way of creating a coating thickness standard on the substrate material, surface finish or form.
-
product
Stand Alone/ Bench Top Load Cell Amplifier/ Conditioner Module
MODEL TMO-2A
The TMO-2A Transducer Modules is a complete differential amplifier/signal conditioners with self contained power. The unit provide excitation, balance and span adjustment via precision 10 turn pots, and shunt calibration necessary to couple a user supplied bridge type transducer to an indicating instrument. Zero to full scale output is specified at 4-20 mA. The TMO-2A provides a floating shunt calibration circuit which applies calibration at the transducer, thereby eliminating errors due to line...show more -
product
Receiver Conformance Test Application for IEEE 802.3ck
M8091CKCA
Designed to assist and simplify the stress signal calibration used for testing the inputs of IEEE 802.3ck Draft 3.3 chip-to-chip (C2C) and chip-to-module (C2M) electrical interfaces using Keysight M8040A 64Gbaud Higher Performance BERT or an M8050A 120Gbd High-Performance BERT together with Keysight Digital Communication Analyzer (DCA) Oscilloscope or Infiniium UXR real-time Oscilloscope.
-
product
10-meter (33 feet) Sensor Cable
E1739B
The E1739B 10-meter (33 feet) Sensor Cable is used to connect the E1736A USB Sensor Hub to either the E1737A Material Temperature Sensor or the E1738A Air Sensor. The connectors at either end of a sensor cable are identical. It is part of the 5530 Laser Calibration System.Other cable lengths available: E1739A 5-meter (16 feet), E1739C (49 feet) 15-meter and E1739D 25-meter (82 feet).
-
product
Sound Level Calibrators
PeakTech Prüf- und Messtechnik GmbH
For sound level measurements in extreme conditions, at high altitudes or high demands on the accuracy of the measurement results, sound level meters should be checked prior to the measurement with a sound level calibrator. Also for calibration and verification of microphones in audio technology, you need a sound level calibrator, which is designed to produce several sound pressure levels at a fixed frequency characteristic. This calibrator has two switchable calibration steps.
-
product
Temperature Data Acquistion
THERMES-USB RF
Physitemp’s original Thermes high accuracy ISA based data acquisition system has been redesigned to create a more versatile USB model. The new system requires no internal connections to your computer and simply connects via an external USB port on your laptop or desktop computer. Two versions of the data acquisition system are available. The standard version, THERMES USB, is connected to your computer USB port. The wireless version - THERMES USB WFI, can be either directly connected to a USB por...show more -
product
Acoustic Calibrators
When you're ready to take noise measurements, it's strongly recommended that you perform a field calibration using an Acoustic Calibrator. You should calibrate your sound meter before you start to measure, and then once you've finished you should perform a reference check against the calibrator and make note of any drift that has occured. You can find out more about performing Field Calibrators by reading this post and watching a short video.
-
product
Open-Short-Load RF calibration kits
Open-Short-Load RF calibration kits from Fairview Microwave are available with Type N or 7/16 DIN connectors. Type N open-short-load RF calibration kits have male or female genders, 7/16 DIN open-short-load kits are male gender. Type N open-short-load (OSL) calibration kits for RF have a minimum frequency of 0 (DC) and a maximum frequency range between 4 GHz and 6 GHz. Type N open short load kits for calibration have a maximum power handling of between 1 Watt and 2 Watts.
-
product
Conformance Calibration Standard Test Card for ITF-14 (Interleaved 2 of 5) Symbol Verifiers
AI-CCS-ITF-14
This test card is ideal for testing verifiers, scanners, and other ITF-14 (Interleaved 2 of 5) barcode reading equipment. It also can serve as an excellent training aid to ensure new operators are using the proper methodology and are proven competent in the use of verifiers.
-
product
Silicon Diodes
DT-670 Series
DT-670 Series silicon diodes offer better accuracy over a wider temperature range than any previously marketed silicon diodes. Conforming to the Curve DT-670 standard voltage versus temperature response curve, sensors within the DT-670 series are interchangeable and, for many applications, do not require individual calibration. DT-670 sensors in the SD package are available in four tolerance bands—three for general cryogenic use across the 1.4 K to 500 K temperature range and one that ...show more -
product
Temp Characterized CalPod, 20 GHz
85531B
CalPods provide a new and unique way to quickly and easily refresh a network analyzer calibration, at the push of a button and without removing the DUT or re-connecting standards. Very useful in thermal chamber testing, where it is desired to remove the thermal effects of the test cables and connectors from the DUT’s response, and where it is impractical to stop the thermal testing to perform a normal re-calibration.
-
product
Pressure Transmitter For Industrial Applications, Ratiometric Output
Series 21 C
KELLER AG für Druckmesstechnik
The C-series transmitters are noted for their ability to deliver high accuracy over a wide temperature range. This is achieved by means of mathematical modelling of the sensor characteristics and digital compensation. In order to do this, each transmitter is gauged over pressure and temperature, programmed and checked after calibration in the same test set-up.
-
product
Mobile ASA-Livestream Data Node for Main Inspection
CONNECT CUBE V3 | VP 185076
Maschinenbau Haldenwang GmbH & Co. KG.
The mobile data node is the right tool for quick and digital diagnosis of the brake system as well as for routine testing and calibration of all ASA livestream-capable brake testers. The plug & play solution can also be used for modern routine testing and calibration of brake test stands.
-
product
Low Current DC/AC Clamp Meter
SE-07
Max.error by earth magnetic:≤±30mA1/f noise level :0.5mADisplay:3 3/4 digits LCD display with 3999 countsJaw size: 5mm(Max)Range:400mA/4AResolution:0.1mABand wide up to 1KHzOver range indication:Display“0L" or“-0L”Auto range,Auto power off,Auto zero adjustReading Rate:2.5 readings/secAuto Calibration