NovoTest
Hardness testing blocks are designed for metals hardness testers calibration.
-
-
ULTIMA® X5000 -
MSA
The ULTIMA® X5000 Gas Monitor is the future of gas detection for oxygen, toxic and combustible gases. MSA XCell® gas sensors with TruCal® technology offer calibration cycles up to 24 months (local calibration respected).
-
IR-518/301 -
Infrared Systems Development Corp.
The IR-518 Radiation Source provides an accurate, stable source of infrared radiation of known flux and spectral distribution. It can be used as a standard radiation source for the calibration of other laboratory sources, detectors, or other infrared devices requiring calibration against a standard.
-
9840 -
Interface Inc.
The 9840 is suitable for use in calibration labs, field service, or anywhere high accuracy is important. Features include a bipolar 6-digit 2-line display, remote sense, low noise, 22-bit resolution, USB port with RS232 communication, mV/V calibration and the ability to store up to 25 different sensors. 6-point linearization, unit conversion, front-panel tare. Self calibration via TEDS Plug & Play ready IEEE1451.4 compliance.
-
LD-LBWM-A10 -
Labodam
Benchtop Water hardness meterLD-LBWM-A10is equipped with large backlit LCD display, 2 to 5 points calibration with low to high concentration range. The calibration due reminder alerts user for calibration of the meter on regular basis. The System menu allows setting the 7 parameters like stability condition, auto-power off etc. It measure salts of calcium & other elements at mg/L, mmol/ scale which causes hardness water.
-
332D-11 VG -
Tech-Aid Products
This printed circuit board was designed to original specifications and contains OEM specified parts. This board is required for testing the 332D-11 series gyros. Also contained on board is the Method A type calibration and sample and hold circuits required to perform the calibration of the noise circuits.
-
Process Insights, Inc.
We are internationally recognized as a leading developer and manufacturer of the high-quality MBW Calibration chilled mirror dew point hygrometers used in a variety of humidity calibration, measurement and gas quality applications. Most notably, our MBW instruments provide the calibration traceability for many laboratories such as humidity instrument manufacturers and National Metrology Institutes. Our MBW chilled dew point mirrors continue to be chosen as transfer standards for inter-laboratory comparisons both regionally and internationally.
-
Model T700 -
Teledyne Advanced Pollution Instrumentation
The Model T700 is a microprocessor based calibrator for precision gas analyzers. Using highly accurate mass flow controllers combined with compressed sources of standard gases, calibration standards are provided for multipoint span and zero calibrations using up to 4 gas sources.The Model T700 can be equipped with an optional UV ozone generator for accurate, dependable ozone calibrations, and to enable production of NO2 when blended with NO gas in the included, internal gas phase titration (GPT) chamber. An optional photometer allows even more precise control of the ozone generator giving accurate and dependable ozone calibrations and enhanced GPTs. To ensure the highest accuracy of NO2 output, the T700 with the photometer option can measure the ozone concentration prior to performing a GPT. A nearly unlimited number of calibration sequences may be programmed into the non-volatile memory of the Model T700, covering time periods up to a year.
-
Metra Blansko a.s.
Tachometers - The customer must provide the generator (JA 13) for calibration with the instrument.
-
CONNECT CUBE V3 | VP 185076 -
Maschinenbau Haldenwang GmbH & Co. KG.
The mobile data node is the right tool for quick and digital diagnosis of the brake system as well as for routine testing and calibration of all ASA livestream-capable brake testers. The plug & play solution can also be used for modern routine testing and calibration of brake test stands.
-
OAI
To insure repeatable testing on any solar simulator, OAI offers 2cm x 2cm calibrated reference cells. Standard reference cell calibration cycles can be set up by OAI''s calibration laboratory to insure that your reference cell maintains certification.
-
LAQUA PD210 -
HORIBA, Ltd.
- Automatic pH calibration - up to 5 points (NIST, USA pH buffers) / up to 6 points (DIN pH buffers)- 0.01 pH resolution- Offset and average slope display - Automatic / manual temperature compensation and temperature calibration function- ORP calibration option- Dissolved oxygen (DO) concentration in ppm (mg/L) and % saturation- 0.01 mg/L or 0.1% DO resolution- Compensates salinity, temperature, and atmospheric pressure - Up to 2 DO calibration points - Auto log data; built-in memory can store up to 500 data- Auto shut-off (programmable: up to 30 minutes)- Auto stable, auto hold, and real time measurement modes- Calibration alarm (programmable: up to 90 days)- Built-in electrode holder allows 2 electrodes to be attached- Monochrome LCD with white LED backlight: 50 x 50 mm- Casing is IP67 waterproof/dustproof, shock & scratch resistant, non-slip- Powered by 2 x AA batteries- Packaged with electrodes and calibration solutions in carrying case- 3 years meter warranty