Showing results: 16 - 30 of 280 items found.
-
-
-
-
1047 -
The Eastern Specialty Company
TESCO’s new CT Ratio/Burden Tester (Catalog No. 1047) is a lightweight, portable and highly accurate in-service test set to assist in finding lost revenue by testing the accuracy of your meter circuits. The Tester can help determine if there are installations errors, loose connections, incorrect ratios, resistance buildup, open CT’s, or manufacturers defects. The CT Ratio/Burden Tester measures and displays the primary and secondary current of the CT under test, and the ratio of the currents. All test data is stored in the internal memory and easily uploaded to a PC.
-
GOM GmbH
The GOM CT scans complex components in one measuring sequence and thus makes the entire part including internal structures available with component positioning performed automatically. GOM CT technical specifications: 225-kV x-ray source | 3k detector | Measuring Volume: 240 mm x 400 mm | Photogrammetric Calibration | Temperature balancing | 5-axis kinematics.
-
CTPTA-504 -
UDEYRAJ ELECTRICALS PRIVATE LIMITED
UDEY ‘CTPTA-504 is a comprehensive CT and PT analyzer. It’s constant voltage and current is highly stable. DSP system controls the constant voltage and current source output and amplitude. This source generates AC of 0-125V and or DC of 0-0.5A current to sample CT. The DSP system besides controlling the sources, also samples data and communicates with the internal computer. Display screen is large LCD with touch pad. The analyzer is highly accurate with high noise immunity and is very user friendly.
-
Tokyo Seimitsu Co., Ltd.
The surface and the internal parts, in one measurement. We provide “Dimensional X-ray CT System” that does not only observe the interior of the workpiece, but that can also perform high precision, contactless measurements.
-
505B -
Red Phase Instruments Australia Pty Ltd.
Field testing kWh meters is easy, field testing CTs when live is much more difficult. Our admittance tester can test CTs live with 50Hz or 60Hz current in the metering circuit. This technique does not confirm the accuracy of a CT but it will detect faults that give metering errors, such as shorted turns, metering circuits shorted to ground and tampering of CTs. CT faults can cause large revenue losses. Admittance testing only adds 10 minutes to a routine polyphase meter test, giving cheap insurance.
-
Nikon Instruments Inc.
Systems offer a microfocus X-ray source, a large inspection volume, high image resolution and is ready for ultrafast CT reconstruction. They cover a wide range of applications, including the inspection of plastic parts, small castings and complex mechanisms as well as researching materials and natural specimens.
-
585 -
Radian Research, Inc.
The 585 Burden Tester is a hand held unit rated for use up to 20A. The design features a digital LED meter for displaying the current transformer (CT) secondary current. The burden is applied for a specific length of time controlled by circuitry inside the unit to help prevent the burnout of the burden elements.
-
-
-
-
-