Filter Results By:

Products

Applications

Manufacturers

CT

1) Current Transformer 2) Computed Tomography


Showing results: 271 - 281 of 281 items found.

  • Failsafe, Normally Open (Terminated), SP8T Multi-Throw Switch, 50Ω Impedance, SMA Connectors, DC-12GHz

    Part No.s CCT-38S/CT-38S​ SP​​​​8T - Teledyne Defense Electronics Relays & Coax Switch

    Normally open, SP8T Multi-Throw switch, 50Ω impedanceIncludes internal 50Ω terminations on unused ports Available in Commercial models, with SMA connectorsDC-12GHz

  • 3-Phase Power & Harmonics Analyzer

    Extech PQ3350 - Extech Instruments Corporation

    Power measurements and analysis + datalogging of single and 3-phase/3-wire or 3-phase/4-wire systems (up to 52,428 single phase readings or 17,476 3-phase readings). Large backlighting LCD displays up to 35 parameters in one screen. Clamp-on True RMS power measurements with on-screen Harmonics display. Simultaneous display of Harmonics and Waveform. Display of Waveform with Peak Values (1024 samples/period). Analysis of Total Harmonic Distortion (THD-F). Maximum Demand (MDkW, MW, kVA, MVA) with programmable period. Adjustable CT ratio (1 to 600) and VT ratio (1 to 3000). Graphic Phase diagram with 3-Phase system parameters. 3-phase Voltage or Current Unbalanced Ratio (VUR, VIR) and Unbalanced Factor (d0%, d2%). Calculated Unbalanced Current through Neutral Line (In). Capture 28 Transient events (including Dip, Swell and Outage) with programmable threshold (%). Optically isolated USB interface with software to download Waveforms, Power Parameters and Harmonics. Includes 4 voltage leads with alligator clips and retractable plunger clips, 8 AA batteries, universal AC adaptor, software, USB interface cable, and case. Current Probes sold separately.

  • 3-Phase Power & Harmonics Analyzer - Complete with 3000A 24" Flexible Current Clamp Probes

    Extech PQ3350-3 - Extech Instruments Corporation

    Complete with 3000A 18" flexible current clamp probes. Datalogging of single and 3-phase/3-wire or 3-phase/4-wire systems (up to 52,428 single phase readings or 17,476 3-phase readings). Flexible clamp probes can be used for wrapping around bus bars and wire bundles. Large backlighting LCD displays up to 35 parameters in one screen. Clamp-on True RMS power measurements with on-screen Harmonics display. Simultaneous display of Harmonics and Waveform. Display of Waveform with Peak Values (1024 samples/period). Analysis of Total Harmonic Distortion (THD-F). Maximum Demand (MDkW, MW, kVA, MVA) with programmable period. Adjustable CT ratio (1 to 600) and VT ratio (1 to 3000). Graphic Phase diagram with 3-Phase system parameters. 3-phase Voltage or Current Unbalanced Ratio (VUR, VIR) and Unbalanced Factor (d0%, d2%). Calculated Unbalanced Current through Neutral Line (In). Capture 28 Transient events (including Dip, Swell and Outage) with programmable threshold (%). Optically isolated USB interface with software to download Waveforms, Power Parameters and Harmonics. Includes 3 flexible current clamps, 4 voltage leads with alligator clips and retractable plunger clips, 8 AA batteries, universal AC adaptor, software, USB interface cable, and case.

  • 3-Phase Power & Harmonics Analyzer - Complete with 1200A 12" Flexible Current Clamp Probes

    Extech PQ3350-1 - Extech Instruments Corporation

    Complete with 1200A 12" flexible current clamp probes. Datalogging of single and 3-phase/3-wire or 3-phase/4-wire systems (up to 52,428 single phase readings or 17,476 3-phase readings). Flexible clamp probes can be used for wrapping around bus bars and wire bundles. Large backlighting LCD displays up to 35 parameters in one screen. Clamp-on True RMS power measurements with on-screen Harmonics display. Simultaneous display of Harmonics and Waveform. Display of Waveform with Peak Values (1024 samples/period). Analysis of Total Harmonic Distortion (THD-F). Maximum Demand (MDkW, MW, kVA, MVA) with programmable period. Adjustable CT ratio (1 to 600) and VT ratio (1 to 3000). Graphic Phase diagram with 3-Phase system parameters. 3-phase Voltage or Current Unbalanced Ratio (VUR, VIR) and Unbalanced Factor (d0%, d2%). Calculated Unbalanced Current through Neutral Line (In). Capture 28 Transient events (including Dip, Swell and Outage) with programmable threshold (%). Optically isolated USB interface with software to download Waveforms, Power Parameters and Harmonics. Includes 3 flexible current clamps, 4 voltage leads with alligator clips and retractable plunger clips, 8 AA batteries, universal AC adaptor, software, USB interface cable, and case

  • Latching (Terminated) SP3T, SP4T, or SP6T Multi-Throw Switch​, 50Ω Impedance, SMA Connectors

    Part No.s CCT-39S/CT-39S SP3T/ SP4T/ SP​​​​6T - Teledyne Defense Electronics Relays & Coax Switch

    Latching, SP3T, SP4T, or SP6T Multi-Throw switch​, 50Ω impedance. Includes internal 50Ω terminations on unused portsAvailable in Commercial and Elite models, with SMA connectorsDC-18GHz ​(commercial) DC-22GHz ​(Elite)

  • Latching (Terminated), SP3T, SP4T, or SP6T Multi-Throw Switch, 50Ω Impedance, 2.92mm Connectors, DC-40GHz

    Part No.s CCT-49K/CT-49K SP3T/ SP4T/ SP​​​​6T - Teledyne Defense Electronics Relays & Coax Switch

    ​​​​​Latching, SP3T, SP4T, or SP6T Multi-Throw switch, 50Ω impedance. Includes internal 50Ω terminations on unused ports​Available in Commercial and Elite models, with 2.92mm ​coconnectorsDC-40GHz

  • Latching (Terminated) SP3T, SP4T, or SP6T Multi-Throw Switch​, 50Ω Impedance, SMA Connectors, DC-26.5GHz

    Part No.s CCT-59S/CT-59S ​ SP3T/ SP4T/ SP​​​​6T - Teledyne Defense Electronics Relays & Coax Switch

    Latching, SP3T, SP4T, or SP6T Multi-Throw switch​, 50Ω impedance. Includes internal 50Ω terminations on unused portsAvailable in Commercial and Elite models, with SMA connectorsDC-26.5GHz​

  • Failsafe, Normally Open (Terminated), SP3T, SP4T, or SP6T Multi-Throw Switch, 50Ω Impedance, K Connectors, DC-40GHz

    Part No.s CCT-48K/CT-48K SP3T/ SP4T/ SP​​​​6T - Teledyne Defense Electronics Relays & Coax Switch

    Normally open, SP3T, SP4T, or SP6T Multi-Throw switch, 50Ω impedance. Includes internal 50Ω terminations on unused portsAvailable in Commercial and Elite models, with K connectorsDC-40​GHz

  • Failsafe, Normally Open (Terminated), SP3T, SP4T, or SP6T Multi-Throw Switch​, 50Ω Impedance, SMA Connectors

    Part No. CCT-38S/CT-38S SP3T/ SP4T /SP​​​​6T - Teledyne Defense Electronics Relays & Coax Switch

    Normally open, SP3T, SP4T, or SP6T Multi-Throw switch​, 50Ω impedance. Includes internal 50Ω terminations on unused portsAvailable in Commercial and Elite models, with SMA connectorsDC-18GHz ​(commercial) DC-22GHz ​(Elite)

  • Three-Phase Transformer Demagnetizer

    DEM60C - IBEKO Power AB

    After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores. The best way to eliminate this source of potential problems is to use demagnetizer on the power or instrument transformer.The DEM60C is a fully automatic test instrument which performs three-phase transformer demagnetization. Transformer magnetic core demagnetization requires the application of AC current with magnitude decreasing to zero. DEM60C provides this AC current by internally changing the polarity of a controlled DC current. During the demagnetization process, the instrument supplies the current at decreasing magnitude for each step, following a proprietary algorithm. It can demagnetize single-phase and three-phase power transformers.The instrument can be connected to all three phases of a power transformer to be demagnetized, on either the primary or the secondary side. If a user selects specific vector diagrams for different types of transformers, DEM60C will run a specific demagnetization procedure for each transformer type (i.e., single phase, delta, wye/star, zig-zag.) without switching the test leads.DEM60C enables safe and efficient power transformer demagnetization. The instrument automatically regulates the injection of current and discharging energy from the inductance. During and after the operation, an intrinsically safe discharge circuit with an indicator rapidly dissipates the stored magnetic energy. The discharging circuit is independent of the power supply, which improves its reliability in case of loss of power.Test currents of up to 60 A DC enable efficient demagnetization of even the largest power transformers. Using a DV Win software, it is possible to control DEM60C externally.

  • Relay Test Set

    RNT-5A - Neutronics Manufacturing Co.

    This is a portable testing kit in one unit, suitable for testing protective relay, over current relay, earth fault relay, protective device, circuit breaker, tripping coils etc.The set is designed for both laboratory and field use. TECHNICAL FEATURES: INPUT : 230 Volts, single phase, 50Hz. AC. OUTPUTS : : 1) Current Output: a) 0- 1Amp. At 6/60Volts. (Continuous duty). b) 0- 5 Amps. At 6/60 Volts. (Continuous duty). c) 0- 10 Amps. At 6/60 Volts. (Continuous duty). d) 0- 20 Amps. At 6 Volts. (for30 min. duty). e) 0- 50 Amps. At 6Volts. (For 10 min. duty). f) 0-100 Amps. At 6 volts. (For10 min. duty). g) 0-200 Amps at 6Volts. (For 30 sec. duty). Current output is continuously variable and the output is taken out through a multi range C.T. The secondary is connected to an ammeter scaled in 0 to 100%. Output current range 1Amp. To 20Amps. Are selected by current range selector switch with common output terminals and for other three ranges three brass terminals are provided of proper ratting. 2) AC Voltage Output: Continuously variable 0 -230V AC. Capacity- 240VA (Max). OR DC Voltage Output: Continuously Variable 0-240V DC. Capacity-240VA.(max). One change over switch should be provided for selection of Volt. Meter for AC or DC voltage output & either AC or Dc voltage should be available at a time. 3) Time Measurement: 0-9.999Secs. & 0-99.99Secs. in two ranges. Accuracy: 1% CURRENT CIRCUIT: Loading transformer: Double winding loading transformer of suitable burden to provided corresponding current output specified before. One change over switch in current ckt. To be provided for voltage selection i.e. selection of 10volt. Or 50volt. Measuring CT: Multi ratio wound primary current transformer Ratio : 1-5-10-20-50-100-200A/5A. Variable auto transformer: For smooth variation of current output at various ranges selected. Tripping circuit: The current output will be cutoff incase of any overload for the range 200A or even if the relay under test actuated.

Get Help