Showing results: 181 - 195 of 247 items found.
-
Model T360M -
Teledyne Monitor Labs
The Model T360M CO2 analyzer measures Carbon Dioxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO2 filled chamber and a chamber with no CO2 present. The light path then travels through the sample cell, which has a folded path of 1.28 meters.The energy loss through the sample cell is compared with the reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing excellent performance over a wide concentration range, making this instrument an ideal choice for CO2 reporting requirements associated with dilution CEMS.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T360M comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.
-
Elemental Analysis, Inc.
Carbon, Hydrogen, Nitrogen are determined using a 2400 Perkin-Elmer CHN Analyzer. This analyzer uses combustion to convert the sample elements to simple gasses, i.e. CO2, H2O, & N2. Upon entering the analyzer, the sample is combusted in pure oxygen environment at temperatures in the range of 1200-1500 F. The product gasses are separated under steady state conditions, and measured as a function of thermal conductivity.
-
Ultrasonic -
Bacharach, Inc.
Bacharach's ultrasonic-based leak detectors support a variety of applications, including: Combustible and Refrigerant Gases, Compressed Air and Pneumatic Systems, Inert Gases (CO2, Nitrogen, Helium, etc.), Steam Trap Leak Detection, Condensate Flow, Thermal Expansion Valves (TXV), Solenoids, Mechanical Problems (Bearings, Wear), Electrical Arcing, Sealed Enclosures, Tanks, and Rooms, and Condition-Based Monitoring:
-
FTX-ONE-CS/RS -
HORIBA, Ltd.
The FTX-ONE offers a 5Hz sampling rate and simultaneously measure the concentrations of multiple components including NH3, CH4, and CO2, from (engine) direct exhaust gas using the Fourier Transform Infrared (FTIR) method in combination with multivariate analysis algorithm.
-
Model GFC-7000T -
Teledyne Analytical Instruments
The GFC Series gas filter correlation analyzers measure low ranges of gases (CO2, CO2 and N2O detecting models available by comparing infrared energy absorbed by a sample to that absorbed by a reference according to Beer-Lambert Law. All GFC Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel or via RS-232, Ethernet or USBcom ports either locally or by remote connection using the included APIcom™ software.
-
Model GFC-7001T -
Teledyne Analytical Instruments
The GFC Series gas filter correlation analyzers measure low ranges of gases (CO2, CO2 and N2O detecting models available by comparing infrared energy absorbed by a sample to that absorbed by a reference according to Beer-Lambert Law. All GFC Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel or via RS-232, Ethernet or USBcom ports either locally or by remote connection using the included APIcom™ software.
-
MET 6.1 | VP 135117 -
Maschinenbau Haldenwang GmbH & Co. KG.
The MET 6.1 exhaust gas analyser is designed for the measurement of petrol-, CNG- and LPG-powered vehicles as well as the precise analysis of the gas components HC, CO, CO2, O2 with lambda value calculation. The MET 6.1 stands out for its innovative condensate separation thanks to an active water separator. In addition, low weight, compact design and short warm-up time ensure easy handling.
-
Iso CHROM® LC -
Elementar Analysensysteme GmbH
Unlike the existing LC-inlet solution via chemical oxidation, the iso CHROM LC works with high-temperature combustion. It quantitatively converts organic carbon to CO2.In addition, the easy-to-use iso CHROM LC shows outstanding precision, accuracy, and linearity without significant peak broadening that can diminish the chromatographic performance. In continuous operation, virtually all peaks in a chromatogram can be analyzed for the stable isotope ratios of carbon.
-
MSR160 -
MSR Electronics GmbH
Four integrated analogue inputs, a high measurement rate of up to 1000/s per channel and its gigantic memory capacity, all packed into a small format are the key characteristics of the MSR160 data logger. The analogue inputs of the robust mini logger can be used for conventional sensors with analogue outputs (e.g. CO2, conductivity, pH etc). In addition, a multiple output switching power supply is also provided.
-
RkT Thermopile Series -
Laser Probe Inc.
The RkT Series thermopile power probes are ideal for measuring Nd:YAG, CO2, and other mid-power lasers. The probes are designed to withstand average power densities up to 20kW/cm2 (15MW/cm2 peak pulse power density). The flat UV to far-IR spectral response allows the probes to measure broadband sources as well. Measure the power of cw sources or the average power of sources pulsed at 5Hz or greater.
-
NSA-3080 -
Shimadzu Corp.
The NSA-3080 is infrared gas analyzer for monitoring stationary sources The NSA-3080 can measure up to five components NOx, SO2, CO, CO2, and O2 with a high degree of accuracy. NSA-3080 uses the ratio infrared absorption method, and it ensures highly stable measurements. The slim cubicle structure used makes maintenance and daily inspections extremely easy to perform. Highly reliable sampling can also be performed with ease.
-
Anton Paar GmbH
Benefit from over 40 years of experience in inline and laboratory beverage analysis: Connect Anton Paar’s versatile and well-proven evaluation units to all generations of Anton Paar density, sound velocity, concentration and CO2 sensors. Let the data acquisition and visualization software master complex measuring tasks for you – bringing home the precision that marks measurement solutions from Anton Paar.
-
MKS Instruments
The DI-CO2 is used in single substrate cleaning tools for rinsing steps to prevent ESD effects and/or corrosion by creating UPW (ultrapure water) with precisely defined conductivity. It is a compact system for tool integration, providing conductive DI-CO2 water (Carbon Dioxide) with closed loop controlled conductivity. The conductivity is kept at a constant value under changing flow conditions by control of the CO2 concentration in the DI-CO2 water.
-
51 Series -
HORIBA, Ltd.
HORIBA’s 51 Series of explosion-proof analyzers provide safe, reliable and accurate measurements when analyzing flammable gases or operating in explosive environments. The 51 Series complies with IEC 60079. The 51 Series explosion-proof analyzers infrared allow for the measurement of CO, CO2, CH4 and other organic gases. The TCA-51 uses a thermal conductivity detector for H2 measurements and the MPA-51 and PMA-51 models integrate magneto-pneumatic and paramagnetic detectors for O2 measurements.
-
Model T100H -
Teledyne Advanced Pollution Instrumentation
The Model T100H SO2 analyzer uses the proven UV fluorescence principle with the high measurement ranges and interferent rejection needed for extractive source monitoring. The Model T100H provides a simple but precise solution for a broad range of CEM and stack testing applications.The instrument design provides minimal quenching by O2 or CO2 and less than a 0.1% response to water in the sample. Additionally, special optical filtering reduces the effects of NO interference.