Filter Results By:

Products

Applications

Manufacturers

Showing results: 1246 - 1260 of 2664 items found.

  • Dew Point Monitor

    DPM-99 - Edgetech Instruments

    The NFPA99 has mandated that for Med Gas systems the "dew point for locally compressed air shall be monitored and alarmed per 4-3.1.9.8 and 4-3.1.1.2(f) to protect from line pressure dew point rise to 39 degrees F (3.9 degrees C) from a nominal design of 35 degrees F (1.7 degrees C)." This safeguard was the foundation for the new Edgetech Instruments DPM-99 Med Gas Dew Point Monitor. This specifically designed monitor exceeds the requirements set forth by the NFPA and was a collaboration with AIRVAC Technical Services who are certified by P.IP.E as medical gas inspectors in all 50 US States.

  • FD-11614, 16-Channel Temperature Input Device for FieldDAQ

    785854-01 - NI

    The FD-11614 measures up to 16 thermocouple channels. It features cold-junction compensation and open thermocouple detection with an LED indicator per channel to identify disconnected thermocouples. The FD-11614 has an ingress … protection rating up to IP67 (dust- and water-resistant), can operate in -40 °C to 85 °C environments, and can sustain 100 g shock and 10 g vibration. The FD-11614 incorporates Time Sensitive Networking (TSN) and features an integrated network switch and built-in power circuitry for simple daisy chaining. You program the FD-11614 with NI-DAQmx, which automatically synchronizes multiple FieldDAQ™ devices. This device is ideal for test cell and outdoor environments.

  • cDAQ-9178, 8‑Slot, USB CompactDAQ Chassis

    781156-01 - NI

    8‑Slot, USB CompactDAQ Chassis - The cDAQ‑9178 is a CompactDAQ USB chassis designed for small, portable sensor measurement systems. The chassis provides the plug‑and‑play simplicity of USB to sensor and electrical measurements. It also controls the timing, synchronization, and data … transfer between C Series I/O modules and an external host. You can use this chassis with a combination of C Series I/O modules to create a mix of analog I/O, digital I/O, and counter/timer measurements. The cDAQ‑9178 also has four 32‑bit general-purpose counters/timers. You can access these counters, as well as share clocks and triggers, through two built-in BNC connectors.

  • Enlarge Environmental Chamber

    REXMED REC-450 - REXMED Industries Co., Ltd.

    MOD. REC-450, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -40˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 1.5KW X 2pcs, Humidity heater: 2.5KW X 1pc, Heat up transition time: -40˚C~100˚C within 45 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 3,644 Watts, 12,433 BTU/hr, 3,140 Kcal/hr, Cool down transition time: 20˚C~-40˚C within 50 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L60 X W80 X H85cm, Capacity: 408L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • Enlarge Environmental Chamber

    REXMED REC-250 - REXMED Industries Co., Ltd.

    MOD. REC-250, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -20˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 1.5KW X 2pcs, Humidity heater: 2.5KW X 1pc, Heat up transition time: -20˚C~100˚C within 35 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 3,140 Watts, 10,700 BTU/hr, 2,702 Kcal/hr, Cool down transition time: 20˚C~-20˚C within 45 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L60 X W80 X H85cm, Capacity: 408L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • Environmental Chamber

    REXMED REC-400 - REXMED Industries Co., Ltd.

    MOD. REC-400, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -40˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 1.5KW X 2pcs, Humidity heater: 2.5KW X 1pc, Heat up transition time: -40˚C~100˚C within 45 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 3,506 Watts, 11,962 BTU/hr, 3,020 Kcal/hr, Cool down transition time: 20˚C~-40˚C within 50 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L50 X W60 X H75cm, Capacity: 225L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • Environmental Chamber

    REXMED REC-280 - REXMED Industries Co., Ltd.

    MOD. REC-280, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -20˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 2.3KW X 2pcs, Humidity heater: 4.5KW X 1pc, Heat up transition time: -20˚C~100˚C within 35 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 3,140 Watts, 10,700 BTU/hr, 2,702 Kcal/hr, Cool down transition time: 20˚C~-20˚C within 45 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L100 X W80 X H100cm, Capacity: 800L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • Enlarge Environmental Chamber

    REXMED REC-480 - REXMED Industries Co., Ltd.

    MOD. REC-480, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -40˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 2.3KW X 2pcs, Humidity heater: 4.5KW X 1pc, Heat up transition time: -40˚C~100˚C within 45 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 5,270 Watts, 18,000 BTU/hr, 4,545 Kcal/hr, Cool down transition time: 20˚C~-40˚C within 50 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L100 X W80 X H100cm, Capacity: 800L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • Environmental Chamber

    REXMED REC-200 - REXMED Industries Co., Ltd.

    MOD. REC-200, AC 230/380/415V, 1/3 phase, Environmental chamber, HS CODE: 841989, UNCCS CODE: 484384, UMDNS CODE: 16327, Main construction: SS304, Interior: SS304, Exterior: SS304 powder coated, Insulation: Rigid polyurethane foam and glass wool, Controller: Fix point PID controller, temperature ˚C/PV and ˚C/SV, humidity %/PV and %/SV display and setting, Temperature range: -20˚C~100˚C, Humidity range: 20%RH~98%RH, Constancy: ±0.3˚C ±2.5%RH, Uniformity: ±1˚C ±3%RH, Temperature and humidity sensor: PT 100Ω, Temperature and humidity audio and visual warning and OFFS correction setting, Temperature heater: 1.5KW X 2pcs, Humidity heater: 2.5KW X 1pc, Heat up transition time: -20˚C~100˚C within 35 min, Refrigeration system: Air cooled, single stage, Cooling compressor: Bristol hermetic compressor, Cooling capacity: 1,892 Watts, 6,455 BTU/hr, 1,630 Kcal/hr, Cool down transition time: 20˚C~-20˚C within 45 min, Safety devices: No fuse breaker, refrigerator over load relay, refrigeration high pressure switch, over temperature protector, protection relay, protection fuse, water level control and overheat protector, Chamber: L50 X W60 X H75cm, Capacity: 225L, chamber with key lock, with lamp (DC 12V 50W) X 1pcs and double glass viewing window, testing cable port with cover: Ø25mm, 4 castors, W/S: shelf X 2pcs, standard testing wet cloth X 5pcs, PCV water container X 1pc

  • Compact Temperature Test Chambers

    TJR - Thermal Product Solutions

    Specifically designed these benchtop and floor chambers to have a compact exterior yet an ample interior workspace to maximize valuable floor space. Temperature Range: -73C - 200 °C. Internal Dimensions: WxDxH (inches) 16 x 11 x 11.75.

  • Emulates Atmel AT89C51SND1

    FE-SND1 - Ceibo Inc.

    * Emulates Atmel AT89C51SND1 * 62K Code Memory * Real-Time Emulation * Frequency up to 20MHz/3V * ISP and X2 Mode Support * MS-Windows Debugger For C And Assembler * Emulation Headers and Signal Testpoints * Programmer Included * Serially Linked to IBM PC at 115Kbaud

  • Low Noise Preamplifier

    The Phased Array Company

    The UPL-3001 preamplifier is a high performance solution for the low-noise amplification of ultrasonic signals. Designed for signals ranging from 0.5 to 300 MHz, the small and lightweight, rugged unit is perfect for remote applications. This is ideal for P&C, TT, AUT or TOFD inspection.

  • Miniature LVDT Position Sensors

    NewTek Sensor Solutions

    Miniature LVDTs are ideal where reliable measurements are needed in small spaces.  With options for venting up to 30,000 psi, and temperature ratings to 400°F (200°C), these LVDTs operate in hydraulic equipment, embedded in robotics, and used in harsh downhole conditions.

  • Near Field Moving Detector Goniophotometer

    LSG-1900B - Lisun Electronics Inc.

    LSG-1900B Goniophotometer is near field Type C automatic goniophotometric instrument for luminous intensity distribution measurement. The LSG-1900B uses a constant temperature detector. It is for industrial laboratory photometric data measurements of small luminaires, such as down light, bulb light, etc.

  • Opto-Engineering Lenses

    ViTec Co. Ltd

    To effectively use the capabilities of the selected camera, it is necessary to choose the appropriate lens in terms of size and resolution. In addition to classical optics, we offer telecentric and special solutions for compact cameras with C / CS-mount and devices with large matrices: F-mount, M42 and others.