Showing results: 1756 - 1770 of 2664 items found.
-
PHHT15 -
Pyle Audio Inc.
Indoor Relative Humidty and Comfort Level IndicatorClock Display with Alarm FunctionSelectable Celsius or Fahrenheit DisplayTemperature Range: -50 to 70C / -58 to 158 FTemperature Accuracy: +/- 1 C (2 F)Humidity Accuracy: +/- 5%Humidity Display Resolution: 1%Sampling Period: 10SBattery: AAA, 1.5V (Included)Dimensions: 4.13' H x 3.94' W x 0.91' DWeight: 4.48 oz.Sold as : Unit
-
LD-LCSA-A12 -
Labodam
IR Carbon and Sulphur Analyzer LCSA–A12 is a unit for determination of sulphur and carbon equipped with two treatment units including a high frequency induction burner and flexible temperature settings with automatic control. With an analysis time of 25 to 60 seconds and 10 to 30 °C, the multi-shielded isolation circuit prevents the machine for high frequency interference. High speed 32-bit sampling improves sensitivity and accuracy.
-
PS300-HRP -
Axiomtek Co., Ltd.
*Input Range: 90 ~ 264VAC Full Range*Output Voltage:**+5V, 25A (3A min)**+3.3V, 18A (1A min)**+12V, 16A (2A min)**-12V, 0.5A**-5V, 0.5A**+5Vsb, 2A (0.1A min)*MTBF(hours): 100,000h*Safety: UL, UL+C, TUV, CB, CE*Dimensions: 185 x 150 x 86 mm*Compatible with Axiomtek products: AX61220
-
PS400-HRP -
Axiomtek Co., Ltd.
*Input Range: 90 ~ 264VAC Full Range*Output Voltage:**+5V, 35A (3A min)**+3.3V, 25A (1A min)**+12V, 28A (2A min)**-12V, 1.2A**-5V, 0.5A**+5Vsb, 2A (0.1A min)*MTBF(hours): 100,000h*Safety: UL, UL+C, TUV, CB, CE*Dimensions: 185 x 150 x 86 mm*Compatible with Axiomtek products: AX6156LE
-
CHY firemate Co., Ltd.
Save data: 128 samples with real-time data.Data logger: 16 sets, Maximum 1024 data capacity.Easy Reads Data with down and up key on meter.T/C Offset Adjust.REC, MAX, MIN, MAX-MIN, AVG, REL, HOLD functions.T1, T2, T1-T2, Time and Memory No.Resolution 0.1°C/1°C, 0.1°F/1°F.Warning beeper with Hi/Lo setting.Real time clock with calendar.Selectable Auto Power Off function.
-
Rhopoint Metrology Ltd
It is intended for reference by component producers and gauge makers when gauge limits have not been stipulated. It specifies gauge tolerances for work piece tolerances in ranges between 0.009mm and 3.200mm and how gauge limits are related to the work piece limits. It also specifies types of gauge according to size and minimum work piece tolerance, dimensions are expressed in millimetres but appropriate values in imperial units are given in appendix C.
-
2575 -
PCB Piezotronics, Inc.
Performance:Nominal Microphone Diameter1"1" Frequency Response: Characteristic (at 0 incidence) Random IncidenceRandom Incidence Open Circuit Sensitivity: 45 mV/Pa Resonant Frequency (90 Phase Shift)8000 Hz8000 Hz[1] Inherent Noise<10 dB(A) re 20 Pa<10 dBTemperature Range (Operating)TBD FTBD C Humidity Coefficient of Sensitivity (0 to 95%, non-condensing)0.001 dB/%RH
-
PS302-XP2 -
Axiomtek Co., Ltd.
*Input Range: 100 ~ 240VAC Full Range*Output Voltage:**+5V, 16A**+12V1, 17A**+12V2, 17A**-12V, 0.3A**+5Vsb, 2.5A**+3.3A, 19A*MTBF(hours): At 25°C, 100,000h*Safety: UL, CSA, CE, FCC*Dimensions: 150 x 140 x 86 mm*Compatible with Axiomtek products: AX61221, AX61222, AX61220, AX61400, AX6156LE, AX60552, AX60501,AX60551, AX61492
-
T&C Power Conversion
100 W to 2400 W 13.56 MHz Analog/Digital, RS-232, USB interfaces Low Harmonic Distortion Automatic and Manual Gain Control High Speed Pulsing (Bursting) controls Compatible with T&C''''s Matching Networks GUI Software (complete PC control) Includes all essential RF power/communication cables and mounting brackets Air cooled (Air & Water 1200 W +) Half rack mount or stand alone versions Ideal for: Industrial, Scientific, and Medical Applications
-
M100T/M5000T -
Electro-Sensors, Inc.
Features• Internal sensor• SPDT relay output• 5-100 rpm (M100T), 100-5,000 rpm (M5000T)• Terminal block for easy wiring• 115, 230 VAC (50-60 Hz) and 12, 24 VDC power options• Works with Electro-Sensors magnetic pulser discs/wraps• Explosion proof (XP) housing• UL Listed Class I, Div I (C, D) Class II (E, F, G)
-
SVR Pro -
Falcon Electric, Inc
*Convenient Rackmount/Tower Design*UL Listed for 55°C Operation in Harsh Environments*True Sinewave Output*Superior Power Conditioning*Wide Input Voltage Window*Precision Output Voltage Regulation*Superior Brownout, Surge & Transient Protection*Frequency Converter Option*Battery Backup Capability Option*LCD Display with Advanced Monitoring for Easy Remote Management*RS-232C, USB & Optional SNMP/HTTP Agent
-
Panasonic Industrial Devices Sales Company of America
Mechanical Relays that can switch up to 2A. Ideal for low load switching, signal control, etc. Features include gold contacts, stable contact resistance, fully sealed construction, Form C contact arrangement, available latching and low operating power, and compact size for optimal board space usage. Applications include: AC Control, Communications, Security, Measurement Equipment, Audio Visual Devices and Automotive.
-
Series KLP -
Kepco, Inc.
The KLP is an entirely new laboratory grade power supply in which the voltage/current limits are automatically recalculated, forming a constant-power hyperbolic-shaped boundary between the voltage and current modes. This curve, which replaces the single max-power operating point of conventional power supplies, provides the user with a greatly expanded choice of maximum power volt-ampere combinations as illustrated in the diagram by points A to B to C. The constant-power limit of the KLP is 1200 watts.
-
ALx Series -
Magna-Power Electronics, Inc.
The ALx Series utilizes conventional linear MOSFET-based dissipative elements, allowing the series to achieve a very wide voltage-current operating range within the model’s maximum power rating. Using the same heat management innovations developed for Magna-Power’s high density programmable DC power supplies, the ALx Series’ conservative cooling ensures long product life in environments up to 50 °C ambient operating temperature.
-
Analog Devices Inc.
Analog Devices analog temperature sensors provide current or voltage output proportional to the absolute temperature with accuracies of up to ±1°C. Our diverse range of analog output temperatures sensors can be used in a broad range of applications with no need for external calibration, and with minimal signal conditioning/conversion circuitry. To better suit your varied design needs, our portfolio of temperature sensors are available in multiple package options.