  • Acquisition Of 8 Displacement Transducers

    APCI-3701-8 - TEAM SOLUTIONS, INC.

    PCI interface to the 32-bit data bus Acquisition of 16 or 8 inductive displacement transducers (Half Bridge, LVDT) 8 or 16 input channels ± 10 V 16-bit resolution Measuring frequency up to 100 kHz Conversion can be triggered through software End of conversion can be inquired through software Possibility of interrupt through digital input channels (when a data or a time value is exceeded) PCI-DMA access Onboard FIFO buffers Sequence RAM 16 isolated digital I/O, 24 V Software operation Supported inductive transducers for APCI-3701Standard board APCI-3701-8 or APCI-3701-16Transducer type:

  • CoolMaster

    1000D - Dimax

    CoolMaster 1000D is versatile bridge device connecting Daikin VRV Air Conditioning systems and any RS232 or USB capable device like Home PC, Embedded PC or Home Automation Controller. Exposing simple interface over RS232 communication line or USB bus, CoolMaster gains user application full control on indoor units and provides access to VRV system parameters. In other words CoolMaster hides complexity of internal Daikin Communication line (including very unique physical layer) and instead gives simple, comprehensive, well documented protocol running on popular RS232 or USB connection.

  • CoreCommander

    JTAG Technologies Inc.

    While many ICs are equipped with a JTAG (IEEE Std. 1149.1) boundary-scan register (BSR), a significant number of microprocessors and DSPs can be found with deficient or even non-existent BSRs. CoreCommander Micro uses the on-chip debug mode of processors to access ports and embedded peripheral controllers to promote ''kernel-centric'' testing. Similarly, in the case of today's Field Programmable Gate Arrays (FPGAs) test engineers can ''bridge'' from the JTAG interface to the resources of the gate array itself. Our CoreCommander FPGA product implements a translatorinterface that allows our JTAG hardware to control embedded IP cores via a variety of bus interfaces (e.g. Wishbone Avalon etc.).

  • IRIG-B TTL TO RS485 Converter

    SPC - INS - 1010 - Signals & Systems India Private Limited

    The IRIG-B TTL signal is a time synchronization protocol that can be transmitted up to 50m maximum using coaxial cable. So the relay which is to be received the IRIG-B TTL signal may be far away from the IRIG-B source. The relay may be not able to synchronize with the GPS. To avoid such an incident in the field, some of the relays have provision to receive IRIG-B RS485 signal. The IRIG-B RS485 signal can able travel up to 1200m without any booster. All Time source equipment may not be supplied with IRIG-B RS485 signal output. The converter will act as a bridge between GPS Time source and Relays for time synchronization.

  • 6U CompactPCI® Dual PMC or CMC Carrier Board (64-bit/66 MHz)

    MIC-3951 - Advantech Co. Ltd.

    The MIC-3951 is a 6U CompactPCI carrier board for PCI Mezzanine Cards (PMC) modules. It provides two 64-bit PMC sites for easy CompactPCI system expansion through different PMC modules. An Intel® 21154 PCI-to-PCI bridge chip is used in the MIC-3951 for CompactPCI bus expansion and decreases the CompactPCI bus loading to one, in addition to meeting industry requirements. Advantech provides several PMC modules that work in conjunction with the MIC-3951, such as the inclusive 10/100 Ethernet module and Gigabit module. In addition to being compatible with Advantech CompactPCI products, the MIC-3951 can also be used with other standardized, off-the-shelf modules from other manufacturers.

  • Load Cell Amplifier Signal Conditioner with DB9 Connectors

    MODEL LCA-9PC - Transducer Techniques, Inc

    The LCA-9PC Module provides low-cost, dedicated signal conditioning for a single bridge type load cell or torque sensor. Model LCA-9PC comes with DB9 male and female connectors, which require soldering to user-furnished mating female or male wire connectors. On- board jumper selections include sensitivities from 0.5 mV/V to 10 mV/V, bandwidths from 100 Hz to 30 kHz, and amplified outputs of 0 to ±5V, 0 to ±10V, 0-16 mA, 0-20 mA or 4-20 mA. Zero and span adjustments are via precision 25-turn low-tempco metal film otentiometers.The units can be operated next to the sensor with 4-wire hookup or at distances up to 1 km (3300 feet) with 6-wire hookup. An onboard 87.325 kΩ resistor allows easy shunt calibration at the push of a button. Provision is also made for a user-furnished calibration resistor. Power requirements are 11.8 to 26V DC with load currents from 10 to 60 mA, the latter applying when the unit provides 10V DC excitation to a 350 ohm load cell and delivers a 20 mA analog output.

  • Load Cell Amplifier Signal Conditioner with Removeable Terminals

    MODEL LCA-RTC - Transducer Techniques, Inc

    The LCA-RTC Module provide low-cost, dedicated signal conditioning for a single bridge type load cell or torque sensor. Model LCA-RTC comes with removable screw-clamp terminal connectors, which accept wires without soldering.On- board jumper selections include sensitivities from 0.5 mV/V to 10 mV/V, bandwidths from 100 Hz to 30 kHz, and amplified outputs of 0 to ±5V, 0 to ±10V, 0-16 mA, 0-20 mA or 4-20 mA. Zero and span adjustments are via precision 25-turn low-tempco metal film potentiometers.The units can be operated next to the sensor with 4-wire hookup or at distances up to 1 km (3300 feet) with 6-wire hookup. An onboard 87.325 kΩ resistor allows easy shunt calibration at the push of a button. Provision is also made for a user-furnished calibration resistor. Power requirements are 11.8 to 26V DC with load currents from 10 to 60 mA, the latter applying when the unit provides 10V DC excitation to a 350 ohm load cell and delivers a 20 mA analog output.

  • 100 Ampere Micro OHM Meters

    Neutronics Manufacturing Co.

    Introduction: Measuring the line loop contact resistance by bridges is not the ideal method as the test current is only a few milli amperes. Thus the value is not the true value of the contact resistance. Model HL- 100 is a direct reading tester,  and uses a test current of 100A DC,  resulting in true v alue and accur ate measurements. Model HL- 100 adopts digital circuit technique and is used for measuring contact resistance of switch control equipments at test current of 100A DC. The measurements are accurate as the test is highly stable.HL- 100 is a new,  fully automatic micro controlled tester that measures contact resistance at 100A DC with built in printer. The advantages of HL-100

  • Fully Automatic Transformer Turns Ratio Tester

    DY100 - Neutronics Manufacturing Co.

    DY-100 is a new generation, fully automatic, transformer turns ratio tester designed for measuring ratio, ratio error of single and three phase transformers. The entire test is done automatically and quickly. Operator enters the test parameters and DY-100 tak es over; powers up the voltage, balances the bridge, takes the readings, and displays the results on the LCD screen. Prints testresults through its built-in printer. A key feature of the DY-100 is automatic measure transformer connection group. LV and HV windings are automatically isolated once the measurement is over. True portability is achieved by the lightweight (only 10 kg), single unit design housing the DY-100. The DY-100 is encased in an aluminum alloy cabinet.

  • Load Cell Transducer

    Unitech Scales And Measurements Pvt. Ltd

    Force can be measured by different methods, one of the most effective and accurate method is by using strain gauge based load cells. Four Transducer class strain gauges are bonded on the specimen and are connected in the form of Whetstone Bridge. The specimens are of different types depending on the requirement such as S, column, beam, ring, shear beam, binocular etc. UNITEH’S Load Cells are used for wide applications rite from commercial weighing scale to industrial process controlling, R & D applications and educational institutions. UNITECH’S manufacture load cells from 1Kg to 100Tons for compression or tension or universal (Compression and tension) applications. We also undertake custom built load cells for specific requirement and for OEM users.

  • Transformer Winding Resistance Meter

    XWRM-10 - The Motwane Manufacturing Company

    The Motwane make XWRM-10 is a dual channel 10A rated, Transformer Winding Resistance Meter designed and developed aftere xtensive research on challenges and requirements of testing of various Transformer winding resistance. The instrument has One Current channel and two Resistance Channels. The instrument provides a large open circuit voltage of 42Volts, for fast charging of the highly inductive windings of transformers, to provide stable resistance values in minimum time. The XWRM-10 is intended to replace complex bridge set up with a single compact instrumentThe XWRM-10 is based on 4-wire measurement methodto measure low resistance accurately. The instrument iswell protected against inductive kickbacks offered by theinductive windings and gives stable reading on varioustypes of transformers.

  • Stand Alone/ Bench Top Load Cell Amplifier/ Conditioner Module

    MODEL TMO-2A - Transducer Techniques, Inc

    The TMO-2A Transducer Modules is a complete differential amplifier/signal conditioners with self contained power. The unit provide excitation, balance and span adjustment via precision 10 turn pots, and shunt calibration necessary to couple a user supplied bridge type transducer to an indicating instrument. Zero to full scale output is specified at 4-20 mA. The TMO-2A provides a floating shunt calibration circuit which applies calibration at the transducer, thereby eliminating errors due to line losses. The excitation supply incorporates a Wagner Ground to greatly improve Common Mode Rejection. The factory set bandwidth of the module is narrow to improve stability. The removal of a single capacitor will increase the frequency response DC to 60K Hz for dynamic data applications.

  • Instrument Grade Data Sensor

    WISER 8000 - TECAT Performance Systems, LLC

    The TECAT WISER Model 8000 dual strain measurement and monitoring system is a wireless data acquisition system for measuring two external strain channels at high data rates up to 8kHz. The small, light, power-efficient, and non-invasive design enables strain measurements in a wide range of applications. With dual external sensor inputs two Micro-Measurements strain gauge bridges can be measured by a single system, for example to measure both thrust and torque loads simultaneously.The Model 8000 has a long range data transmission of >1,000 meters with up to +/- 0.025% FSR sensitivity for remote measurements. After initial setup using the WISER software interface, the system can be wired directly to your DAQ system, for seamless data collection.

  • Vibration Meters

    PCE Instruments

    A vibration meter is used in manufacturing for machine condition monitoring, product testing and quality assurance. Many machine maintenance technicians use vibration meter devices in tandem with sound level meters to analyze frequency. A vibration meter also can be used in civil engineering to measure the vibration of structures such as buildings, roads and bridges. In addition, specialized vibration meter devices can be used to measure the vibration of the human body. Any vibration meter will measure one or more of the following parameters: vibration acceleration, vibration velocity (speed) and / or vibration displacement.A vibration meter is typically a portable device with a memory for storing measurements. Most vibration meter models feature a built-in data logger for collecting and recording vibration measurement data over time. In this way, vibration measurement data can be acquired with great precision.

  • Programmable Signal Conditioning

    DTX 5000 Series - R.C. Electronics, Inc.

    The DTX-5000 Signal Conditioner Series provides up to 64 channels of state-of-the-art signal processing in a compact (5U) chassis. Using hybrid mixed-signal technology, high-performance analog circuitry is combined with Digital Signal Processing to give gain accuracy performance previously available only in larger customized modules. A simple-to-use graphical user interface running under the Windows 2000 operating system allows for ease of setup and either local or remote operation as a network-based instrument node. The suite of conditioner modules include a strain amplifier with internal bridge completion, a general-purpose instrumentation amplifier with selectable AC or DC coupling, a linearized thermocouple amplifier with cold-junction compensation, a frequency-to-voltage converter with dual inputs for direction sensing, and an ICP accelerometer amplifier with constant-current excitation.