Showing results: 46 - 60 of 194 items found.
-
HSCH-9161 -
Keysight Technologies
The HSCH-9161 is suitable for medium-low barrier, zero bias detector applications. The HSCH-9161 is functional through W-band (110 GHz) and can be mounted in microstrip, finline, and coplanar circuits.
-
HSCH-9162 -
Keysight Technologies
The HSCH-9162 is suitable for medium-low barrier, zero bias detector applications. The HSCH-9162 is functional through W-band (110 GHz) and can be mounted in microstrip, finline, and coplanar circuits.
-
Analog Devices Inc.
Low input bias current op amps are required whenever the difference of currents or voltage is small and needs to be measured accurately. These op amps are used so that the signal is not loaded down by the input of the op amps. Low input bias current op amps are critical for interfacing sensors in applications from photodiodes, pH meters, or other electrometer related functions to downstream electronics. Analog Devices has many precision op amps that fit the definition and range of these applications.
-
N5293AX52 -
Keysight Technologies
The Keysight N5293AX52 is a broadband frequency extension module designed for use with Keysight’s new PNA / PNA-X-based millimeter-wave solutions. It is a compact, lightweight, and ruggedize frequency extender module with built-in bias tee for pulsed DC bias operation. It interfaces with the Keysight N5292A test set controller. The modules allow users to extend the frequency coverage of a base PNA / PNA-X Series network analyzers to a range of 10 MHz to 110 GHz. For more information about cable and accessories for use with network analyzers, please visit Network Analyzer Accessories.
-
N5295AX02 -
Keysight Technologies
The N5295AX02 is a compact and broadband frequency extender with built-in pulsed bias-tee and provides 10 MHz to 120 GHz single-sweep measurements with N5292A test set controller systemized with a PNA/PNA-X B vector network analyzer.
-
N5293AX02 -
Keysight Technologies
The N5293AX02 is a compact and broadband frequency extender with built-in pulsed bias-tee and provides 10 MHz to 110 GHz single-sweep measurements with N5292A test set controller systemized with a PNA/PNA-X B vector network analyzer.
-
N5295AX52 -
Keysight Technologies
The N5295AX52 is a compact and broadband frequency extender with built-in pulsed bias-tee and provides 10 MHz to 120 GHz single-sweep measurements with N5292A test set controller systemized with a PNA/PNA-X B vector network analyzer.
-
Analog Devices Inc.
Low input bias current op amps are required whenever the difference of currents or voltage is small and needs to be measured accurately. These op amps are used so that the signal is not loaded down by the input of the op amps. Low input bias current op amps are critical for interfacing sensors in applications from photodiodes, pH meters, or other electrometer related functions to downstream electronics. Analog Devices has many precision op amps that fit the definition and range of these applications.
-
AtlanTecRF
Atlantic Microwave offer tunnel diode and zero bias detectors.
-
-
-
-
MS-IMU3020 -
MEMSense, LLC
The MS-IMU3020 delivers market leading price to performance in an ultra-compact aluminum package. The gyro bias instability of 0.9 /h and accelerometer bias instability of 9 g supply ample performance to support a range of applications from UAS navigation and control to pipeline inspection.
-
EE105T-xx -
Executive Engineering
The EE105T pre-wired bias power cable is designed to be used with the EE301xx & EE151xx series electronic loads. The cable allows you to connect the electronic load to a regulated 12Vdc bias power supply for operation of the electronic circuits in the load or by moving a wire use the 15-24 Volts unregulated input
-
11970A -
Keysight Technologies
The Keysight 11970A waveguide mixer is a general-purpose harmonic mixer employing a dual-diode design to achieve flat frequency response and low conversion loss. These are achieved without external dc bias or tuning stubs. Manual operation and computer-controlled hardware operation are simplified because mixer bias and tuning adjustment are not required.