product
Sonel Make Digital Insulation Resistance Tester
Sonel (Poland) Digital Insulation Resistance Tester, Range : 0-5kV/5TeraOhms, Battery-cum-Mains Operated, Voltage increment in Steps of 50v & 100V upto 5kV, Memory storage upto 11880 records, Data Transfer to PC/Laptop by USB Port, Free Software, PI & DAR Measurements.
-
product
Resistance Bridges
Provides the best in measurement uncertainties for Direct Current Comparator (DCC) Resistance Bridges. Unique innovations in 6622A design and modularity means users no longer have to decide what Bridge satisfies current requirements as well as future requirements. Optional modules allow for normal, high ohms, and low ohms measurements without having to purchase multiple bridges as per competitive products.
-
product
Contacts Resistance Tester
JYK II
•Instrument IPC architecture for domestic production of all models of metal contacts SF6 switchgear, GIS combination of electrical, vacuum switch, oil switch and column switches, contacts and so on.•Sensor: Acceleration speed sensor, rotation speed sensor, linear stroke sensorinstallation is very easy and simple.•Trigger: The trigger, external trigger, the sensor is triggered. Sensor can trigger the circuit breaker manually switching characteristic test, such as a manual column pole division switch.
-
product
Shoe Dielectric Resistance Tester
UI-FT07
Shoe Dielectric Resistance Tester, also named as shoe high voltage withstand tester, is used to test shoe sole and heel electrical insulation, to check shoe performance of voltage withstand and current leakage. It is to test safety shoe dielectric resistance ability (Electrical Hazard Testing) as mentioned in ASTM F2412.
-
product
Handheld Digital Multimeter, 4.5 Digit, Water and Dust Resistant
U1273A
Organic LED (OLED) display for high brightness level and wider viewing angles (up to 160 degrees)Features set that meet traditional industrial requirements and improve productivity and safety Improved accuracy and resolution to meet traditional industrial requirements (30,000 counts resolution with 0.6% for ACV accuracy)Intelligent features to improve productivity and safety (LPF, ZLOW, Smart )Better grip Visual and audible continuity indication in noisy environments Easy access to fuse for simplified maintenance Easy connectivity to PC and internal memory (up to 10,000) for data logging Large rotary switch and buttons that are easy to operate Dust and water resistant casing (IP 54 compliant)Compatible with U1177A/U1117A IR-Bluetooth adapter for remote monitoring & datalogging Altitude: 3000 meters
-
product
Surface Insulation Resistivity Tester
Model SRT1
The model SRT1 is an advanced instrument for measuring surface insulation resistivity following ASTM standard A717 (IEC 404-11). Featuring the improved, patented Allegheny Ludlum Head*, which providesincreased reliability and repeatability while decreasing maintenance costs. Its floating baseplate assures button alignment across the full sample width and length.
-
product
Power Quality, Ground Resistance & Insulation Testers
Improving energy efficiency, reducing downtime, and prolonging the life of your equipment are some of the ways you can save money with Amprobe tools.
-
product
Field-installation Type Electric Resistivity Meter (Four-Wire Transmission)
HE-200R
HE-200R connects resistivity sensor (ERF Series) and measures resistivity and temperature in the sample water. It is suitable for measurement of UPW resistivity.
-
product
Non-Contact (Pulse-Voltage Excitation Method) Ultra-Low Sheet Resistance Measurement System
PVE-80
*No damage measurement by non-contact Pulse-Voltage excitation method*Easy to measure & carry around, Removable stage plate*Easy operation and data processing by PC with Software*Measurement result can shown by 3 types of measurement unit (Sheet resistance[Ohm/Sq], Electric conductivity[S/cm], Electrical conduction[S])*Pulse-Voltage excitation method : Pat. No.5386394 Joint development with Chiba Univ.
-
product
Insulation Resistance Tester
1507
The Fluke 1507 is a versatile, compact, handheld insulation tester for advanced industrial and electrical insulation testing. Its multiple test voltages make it the ideal tool for many troubleshooting, commissioning, and preventative maintenance applications.
-
product
3D inversion geophysical software for Resistivity and Induced Polarization Data
RES3DINV
This program is designed to invert data collected with a rectangular grid of electrodes. The arrays supported include the pole-pole, pole-dipole, inline dipole-dipole, equatorial dipole-dipole and Wenner-Schlumberger. The RES3DINV program uses the smoothness-constrained least-squares inversion technique to produce a 3D model of the subsurface from the apparent resistivity data alone.
-
product
Silicon Resistivity, PN type & Alarm Tester
HS-PSRT
It use Four Probe to test the resistivity and P/N type of wafers、ingots and all type of silicon materials.It can be used by Solar and Semiconductor industry.
-
product
Non-contact Ultra-High Range Sheet Resistance Measurement System
CRN-100
*Ultra-High range sheet resistance measurement for 10E+9 ~ 10E+15 ohm/sq without contacting*Mapping program software;*1. Arranged in a multipoint pattern measurement is programmed*2. 2-D & 3-D mapping software*Easy operation by Windows 7 system software*Measurement data base link with Excel via CSV format file*Unaffected by contact resistance
-
product
Handheld Insulation Resistance Testers
U1450A/60A Series
The U1450A and U1460A series insulation resistance testers are ideal for predictive and preventive maintenance measurement tasks in electrical and industrial applications. With their vast measurement capabilities, efficient automated report generation and high durability, you can accomplish more in a day’s work with the Keysight U1450A and U1460A series insulation resistance testers.
-
product
5kV Insulation Resistance Tester
KV3122
KV Hipot Power Test Equipment Co.,Ltd
KV3122 Insulation Resistance Tester is suitable for measuring the resistance of various insulating materials and the insulation resistance of transformers, motors, cables and electrical equipment. Digital insulation resistance meter is composed of medium and large scale integrated circuits, including high-precision micro current measurement system, digital boost system and automatic discharge circuit.
-
product
Quantum Hall Resistance System
Measurements International Ltd.
Quantum Hall System, System Accuracy to < 0.003 ppm with CCC Model 6200A, System Accuracy to < 0.015 ppm with DCC Model 6020Q, 5 Tesla Standard System Magnet, Stable Controlled Sample Environment, Base Temperature < 3.6 K, Low Operating Costs, Direct Transfer to 100 Ω, 1 kΩ, 10 kΩ, and 100 Ω Standards, System Range 0.1 Ω to 100 kΩ, Graphene Device Values 1 kΩ, 10 kΩ, 12.9064037 kΩ and 100 kΩ, Triple Sample Device Mounting.
-
product
Temperature Stabilized Resistance Standards
Measurements International Ltd.
The temperature stabilized resistance standards offer customers the very best in accuracy, and stability. With 3 different models to choose from, covering the full range of resistance values.
-
product
Resistance Grounded Systems (HRG/LRG)
Neutral Grounding Resistors (NGRs) are used to limit the maximum ground-fault current. Restriction of fault current lowers hazards and reduces damage done to equipment. High Resistance Grounding (HRG) systems are often used on industrial and critical power applications to maintain system uptime during a first ground fault. HRG systems are also used in tripping applications to help control touch potential on portable loads and improve personnel safety.
-
product
Single-Phase Transformer Winding Resistance Meters
RMO-TW Series
RMO-TW series is perfect for winding resistance measurements of inductive objects. It is ideal for testing transformer windings (power transformers, distribution, autotransformers) and for on-load tap changer verification. In addition, any RMO-TW transformer ohmmeter & tap changer analyzer can also perform transformer demagnetization.The series contains 4 models, with maximal test currents from 10 A (RMO10TW) to 50 A (RMO50TW). They are fitted in a portable and lightweight metal housing.All transformer ohmmeters from RMO-TW series generate a true DC ripple-free current with automatically regulated measurement and discharging circuit. The injection of current and discharge of energy from the test object are automatically regulated.Three independent channels enable testing of three windings in series. Consequently, this enables measurements of winding resistance in every tap position of an on-load tap changer without discharging between the tests.DV-Win software enables control and observation of the test process, as well as saving and analyzing the results on a PC. It provides a test report, arranged in a selectable form as an Excel spreadsheet, PDF, Word, or ASCII format. Additionally, DV-Win measures and calculates the OLTC transition time, the ripple and the winding resistance for each tap changing operation. The software can also perform the calculations necessary for the “Heat Run” test. Finally, a user can export all results in the form of a report.
-
product
ITO Sheet Resistance Standards (ITOSRS)
Indium Tin Oxide Sheet Resistance Standards (ITOSRS) from VLSI Standards are NIST-traceable products, intended for calibration of both contact and non-contact sheet resistance measurement tools used in the LCD, flat panel and touch-screen markets.
-
product
Decade Box, Calibrated, Resistance, 7, 1ohm to 11.11111Mohm, 1 %
72-7270 CAL
The 72-7270 CAL from Tenma is a resistance decade box. It is ideal for service, prototype and experimental use. This useful tool may be set resistance value from 1 to 11,111,110 ohm in one ohm increments. The decade accuracy is ±1% resistors used throughout. It has weight of 320g/0.70lb and dimension 14.7cm × 11.7cm × 5.5cm (5.79" × 4.61" × 2.16"). It is typically used in general applications, troubleshooting, maintenance, education and vocational training, production line testing, radio and TV services, working standards, research design & develop, physics laboratory work.
-
product
4 Wire Earth Resistance & Resistivity Tester
4235 ER
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Earth resistivity (ρ) test.● Earth testing at 20Ω, 200Ω, 2kΩ.● Earth voltage measuring : 0-300V AC.● Automatic C spike check.● Automatic P spike check.● 2-Wire test, 3-Wire test, 4-Wire test.● LCM display.● Auto ranging.● Auto power OFF.● Data hold.● 200 measurement results can be saved in the memory and recalled on the display.● Interval between auxiliary earth spikes is 1.0~50.0m.
-
product
DC Air Based Resistance
DC Air Based Resistance Standards are designed for high accuracy resistance calibration in air.
-
product
High Current Resistance Measurement Systems
Measurements International Ltd.
Modular Designed Base Unit with Expanded Capabilities to 10,000 Amp, Complete Turn-key System, Resistance and Temperature Curves, Complete Measurement Systems Available, Proven Technology.
-
product
Ohm-Stat Resistivity Tester with LED Display
Range: 103 1012 ohms -100% accuracyMeasures resistance/resistivity, RTT, RTG and volume resistance with accessoriesAutomatic zeroing and power shut offCE approvedProduct conforms to the ESD S.20.20 spec standardsAutomatic voltage range selectorSmall, lightweight 2.6"x 5"x 1.2" (6.5 x 113 x 3cm), 8.4 oz. (233 g)LED display color indicates rangeLow battery warning lightLED display
-
product
Manual Dielectric Constant, Tan Delta & Resistivity Test Set
*AC and DC test Voltages switched internally.*Direct digital display of test voltages.*Auto ranging and direct read out of volume resistivity.*Cell constant adjustment and Tan Delta zero correction.*Built-in protection for test sample flash over.
-
product
Resistance Tester With Leakage Current (Loop Current)
GT00WD00ZY
*screen display*Double protection insulation*Non-contact measured resistance, safe, fast
-
product
High Resistance Neutral Grounding Devices
HRG systems limit the fault current by placing high resistance between neutral point of transformer (or generator) and ground. As it is not possible to locate the fault point in delta connected systems, an artificial neutral point is created and delta connected system can be grounded. This allows a fault current of a few amperes thus locating the fault point gets easy. When the neutral point is grounded thru high resistance, both continuity of operation is provided during fault condition and sufficient current (typically between 2 A and 10 A) flow is provided for ease of locating the fault point.
-
product
Ground Resistance Testers
IP67 protected top in the industry Test all ground types from Class A to Class D with a single meter Wide 0 to 2000 measurement range Minimize cabling time with innovative earthing rods and cable winder