Product
High 1.73 (49.00) - 8.00 (227.00) High Performance Bias Ball Probe
POGO-1L-8
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
BIP-10 Battery Probes
Battery Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 30Resistance Remark: Probe Resistance Steel: 30 mOhms, Gold plated: 100 mOhmsTest Center (mil): 260Test Center (mm): 6.60Full Travel (mil): 157Full Travel (mm): 4.00Recommended Travel (mil): 126Recommended Travel (mm): 3.20Overall Length (mil): 591Overall Length (mm): 15.00
-
Product
UniPro/UFS Analyzer/Exerciser
Eclipse M52
Analyzer
Implementing a new high speed front end, supporting MIPI M-PHY™ HS-Gear5 at speeds up to 23Gbps, the Eclipse M52 stands as the markets most complete analyzer/exerciser. The Eclipse M52 is the right tool for engineers and developers who need to ensure the correct and efficient operation of technologies employing the high data transfer speeds of the UniPro/UFS specifications.
-
Product
Light 0.60 (17.00) - 2.00 (57.00) High Performance Lead Free Probe
LFRE-72H-2
ICT/FCT Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,700Overall Length (mm): 43.18
-
Product
7kV, 100 MHz, 2.5 pF, 40 M, Rise Time < 3.5 ns, High Voltage Differential Probe
T3HVD7000-100
Differential Probe
7kV, 100 MHz, 2.5 pF, 40 M, Rise Time < 3.5 ns, High Voltage Differential Probe.
-
Product
Light 0.83 (24.00) - 2.00 (57.00) High Performance Lead Free Probe
LFRE-1Z1-2
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1Z1-4-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
BMP-4 Board Marker Probe
BMP-4
ICT/FCT Probe
Current Rating (Amps): .020Voltage Rating (VDC): 12Recommended Duty Cycle: 2 sec. On (min.), 3 sec. OffTest Center (mil): 1,000Test Center (mm): 25.40Full Travel (mil): 79Full Travel (mm): 2.01Recommended Travel (mil): 50Recommended Travel (mm): 1.27Full Marker Travel (mil): 62Full Marker Travel (mm): 1.57Direction of Rotation: CCWScribed Diameter (mil): 50Scribed Diameter (mm): 1.27Test Center Remark: Ø .398 (10.1) or M10
-
Product
CXA-m PXIe Signal Analyzer
M9290A
Signal Analyzer
Deploy a smaller microwave footprint, no trade-off in precision: Rely on fully specified performance up to 26.5 GHz in 4 slots Optimize your balance between speed, sensitivity and accuracy with the choice to operate in swept or FFT modes Perform fast calibrated stimulus response measurement with full-band tracking generator Smooth the transition between R&D, manufacturing, and maintenance: CXA-m is code compatible with benchtop X-Series signal analyzers and ESA spectrum analyzers
-
Product
LFLT-72 High Performance Lead Free Long Travel Probe
LFLT-72
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 100Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 400Full Travel (mm): 10.16Full Travel Remark: High Spring: 350 mil / 8.89 mmRecommended Travel (mil): 317Recommended Travel (mm): 8.05Overall Length (mil): 1,850Overall Length (mm): 46.99
-
Product
Alternate 2.39 (68.00) - 6.00 (170.00) High Performance Bias Ball Probe
POGO-1J-6
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25T-4
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
AC / DC Current Probe, 100 MHz, 30 Arms
N2783B
Oscilloscope Probe
The N2783B current probe is an accurate and reliable solution for measuring AC and DC currents. Using a hybrid technology that includes a Hall effect sensor and an AC current transformer, the probe provides accurate measurement of DC or AC currents up to 30 Arms continuous.
-
Product
Standard 1.10 (31.18) - 4.80 (136.00) Switch Probe
TSP100-J100-1
Switch Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 20Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 1,990Overall Length (mm): 50.60Switch Point (mil): 59Switch Point (mm): 1.50
-
Product
FieldFox C Handheld Microwave Spectrum Analyzer, 6.5 GHz
N9934C
Spectrum Analyzer
Capture elusive signals with up to 120 MHz gap-free, real-time bandwidth. Make accurate spectrum analyzer measurements (± 0.3 dB) without warmup. Perform over-the-air measurements for 5G NR and LTE. Use GPS/GNSS for geolocation and timestamping.
-
Product
Elevated 1.68 (48.00) - 7.00 (198.00) High Performance Lead Free Probe
LFRE-1I40-7
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 0.62 (18.00) - 5.40 (153.00) Probe
LFRE-39T15-5.4
ICT/FCT Probe
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 50,000Overall Length (mil): 1,437Overall Length (mm): 36.50
-
Product
Vector Network Analyzer
ZVL
Vector Network Analyzer
The R&S®ZVL is a compact, cost-efficient, powerful and portable network analyzer. It is ideal for use in development, production, and service. It is the only instrument to combine the functions of a network analyzer, spectrum analyzer, and power meter in a single box, making you much more efficient.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1Z-4-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Elevated 1.68 (48.00) - 7.00 (198.00) High Performance Lead Free Probe
LFRE-1V-7
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Premium 4.49 (127.00) - 12.00 (340.00) High Performance Lead Free Probe
LFRE-25T36-12
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
High 3.12 (88.00) - 8.00 (227.00) High Performance Lead Free Probe
LFRE-72I40-8
ICT/FCT Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,700Overall Length (mm): 43.18
-
Product
Standard 2.90 (82.20) - 5.40 (153.00) Switch Probe
TSP157-C100-1
Switch Probe
Current Rating (Amps): 10Average DC Resistance lower than (mOhm): 20Test Center (mil): 157Test Center (mm): 3.99Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 984Overall Length (mm): 25.00Switch Point (mil): 67Switch Point (mm): 1.70
-
Product
2-port E-Band VNA Using Streamline 20 GHz and 53 GHz 2-port Network Analyzers
N5253E2
Network Analyzer
Cost-effective 2-port E-band vector network analyzer (VNA) system configured with two Streamline VNAs and frequency extenders.
-
Product
Embedded MXM GPU Module with NVIDIA® Quadro® Embedded RTX3000
EGX-MXM-RTX3000
Graphics Card
The EGX-MXM-RTX3000 module features advanced NVIDIA® Turing™ GPU technology in MXM 3.1 Type B form factor. It’s compact, slim and reliable design makes it suitable for mission critical environment. With Quadro® Turing™ TU106 processing cores, EGX-MXM-RTX3000 supports 4 DP1.4 displays offering a flexible and easy solution for medical and gaming applications.
-
Product
Handheld RF Spectrum Analyzer (HSA), 3 GHz
N9340B
RF Spectrum Analyzer
Obtain field-ready performance: portable, rugged, fanless design, clear viewing both day and night, maximum 4-hour batteryGet benchtop performance with 144 dBm DANL, 1.5 dB amplitude accuracy, and < 0.1 s full span sweep timeAchieve powerful measurements: spectrogram, AM/FM/ASK/FSK modulation analysis, AM/FM IBOC measurement, xDSL measurement, and more
-
Product
Ultra High 2.84 (81.00) - 10.00 (283.00) High Performance Lead Free Probe
LFRE-1T30-10
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
PXIe Vector Network Analyzer, 300 kHz to 26.5 GHz
M9375A
Vector Network Analyzer
Pay for only the frequency range you need with a choice of six frequency ranges up to 26.5 GHz Improve accuracy, yield and margins with the best PXI VNA speed, dynamic range, trace noise and stability Add functionality to your test system with a full 2-port VNA that fits in a single PXI slot Address your multiport applications needs by cascading multiple models Increase throughput and lower costs by adding modules in a multi-site configuration
-
Product
Super 3.90 (111.00) - 16.00 (454.00) High Performance Lead Free Probe
LFRE-25H79-16
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
PNA Microwave Network Analyzer
N5224B
Network Analyzer
Meet your toughest measurement challenges with the highest performing microwave network analyzer in the industry Measure S-parameters with the smallest uncertainty and highest stability Efficiently characterize active components with applications that simplify setups Meet your specific budget and measurement needs by customizing to just the right level of performance Accelerate insight into component behavior using a multi-touch display and intuitive user interface Every spec verified, adjustments included Lock in support & peak performance from the start