Product
Standard 1.09 (31.00) - 4.50 (128.00) Long Travel Bead Probe
BPLT-1C-4.5
Bead Target Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 350Full Travel (mm): 8.89Recommended Travel (mil): 317Recommended Travel (mm): 8.05Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,450Overall Length (mm): 36.83Full Travel Remark: Standard Spring: 400 mil / 10,16 mm, High Spring: 350 mil / 8,89 mm
-
Product
Standard 1.55 (44.00) - 3.20 (91.00) General Purpose Probe
HPA-50G
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 590Overall Length (mm): 14.99
-
Product
Radius, Standard 0.61 (17.00) - 2.80 (79.00) General Purpose Probe
HPA-0D
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 635Overall Length (mm): 16.13
-
Product
Optical Frequency Combs
-
The Optical Frequency Comb technology is regarded as a breakthrough technology for measurements with highest accuracy. Lowest phase noise, stable supercontinuum, and turn-key operation make the Menlo Optical Frequency Comb solutions unique in accuracy and reliability. According to our principles: The best Optical Frequency Comb for any application.
-
Product
Standard 0.50 (14.00) - 2.00 (57.00) Non Replaceable General Purpose Probe
A-A-S-R
General Purpose Probe
Current Rating (Amps): 2Average DC Resistance lower than (mOhm): 30Test Center (mil): 39Test Center (mm): 1.00Full Travel (mil): 30Full Travel (mm): 0.76Recommended Travel (mil): 20Recommended Travel (mm): 0.51Overall Length (mil): 310Overall Length (mm): 7.87Rec. Mounting Hole Size (mil): 31.5Rec. Mounting Hole Size (mm): 0.80Recommended Drill Size: #68 or 0.79 mm
-
Product
Reference Standard
-
Beijing GFUVE Electronics Co.,Ltd.
It has been designed for universal laboratory and test applications and is intended for checking and the calibration of reference standards for electrical power and energy.
-
Product
Standard 2.20 (62.00) - 4.80 (136.00) General Purpose Probe
EPA-4D
General Purpose Probe
Current Rating (Amps): 7Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,320Overall Length (mm): 33.53
-
Product
Frequency Counters
-
-Frequency Range : 0.2Hz to 5.5GHz Built-in CMOS Gate Array Fast, High-Resolution, 10 Digits Green LED Display Microprocessor Controlled Reciprocal Technique for Low Frequency Resolution Self Diagnosis Routine Total, RPM Function, Period Low Pass Filter(100KHz, -3dB) Rs-232c Interface(Option)
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1Z-4-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 2.00 (57.00) - 6.00 (170.00) Non Replaceable General Purpose Probe
F-S-R
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 66Recommended Travel (mm): 1.68Overall Length (mil): 780Overall Length (mm): 19.81Rec. Mounting Hole Size (mil): 86Rec. Mounting Hole Size (mm): 2.18Recommended Drill Size: #44
-
Product
Standard 0.62 (18.00) - 5.40 (153.00) Probe
LFRE-39I15-5.4
ICT/FCT Probe
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 50,000Overall Length (mil): 1,437Overall Length (mm): 36.50
-
Product
Standard 1.53 (43.00) - 4.00 (114.00) Bead Probe
BTP-72HF-4
Bead Target Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,700Overall Length (mm): 43.18
-
Product
Pyramid, 3-Sided Chisel 30°, Standard 0.61 (17.00) - 2.80 (79.00) General Purpose Probe
HPA-0T
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 635Overall Length (mm): 16.13
-
Product
Ultra High Frequency Vibrometer
UHF-120
-
Polytec?s New UHF-120 Vibrometer Laser-Doppler Vibrometers (LDV) can characterize the out-of-plane vibrations at ultra-high frequencies. Polytec?s UHF-120 extends the vibration frequency bandwidthup to 600 MHz.
-
Product
Standardize Production Test Software For PCBAs And Electronic Devices
test
The vast majority of test project man-hours are spent on software development, so the choices that teams make in software tools and architecture have significant impact on deployment schedules. Standardizing software across a team or organization increases both efficiency and proficiency, lowering the risk of missed deadlines and improving test quality and reliability. Test software must:
-
Product
Primary Standard Capacitors
GenRad 1404 Series
-
The GenRad 1404 Series standard capacitors are the standard of choice in metrology labs, and still used today by standards bodies around the world. These capacitors have been designed as primary reference standards of capacitance with which working standards can be compared.
-
Product
FREQUENCY SYNTHESIZERS (Insight FS) FROM 30 TO 1250 GHz
-
Insight Product Company introduces a family of new wide band synthesizers of millimeter and submillimeter waves (Insight FS). Insight FS cover frequencies from 30 to 1250 GHz and generate substantial output power. In the millimeter wave range, each synthesizer covers a full waveguide band (Q, U, V, E, W, F, D, G, Y, J). IPWBS provides several options for frequency and amplitude modulation (analog FM/AM modulation, frequency manipulation, pulses modulation).
-
Product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25H-4
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
High Frequency Electromagnetic Software
Sonnet Suites
-
The Sonnet® Suites™ develop precise RF models (S-, Y-, Z-parameters or extracted SPICE model) for planar circuits and antennas. The software requires a physical description of your circuit (arbitrary layout and material properties for metal and dielectrics), and employs a rigorous Method-of-Moments EM analysis based on Maxwell's equations that includes all parasitic, cross-coupling, enclosure and package resonance effects.
-
Product
Frequency Synthesiser
RA062-F2
-
The RA062-F2 is a multiple LO module used to generate three pairs of LO signals, each pair being phase matched in order to provide the capability to drive two phase and amplitude matched, high sensitivity narrowband receivers such as might be required for an EW receiver system with DF functionality.The Stepped Frequency Synthesiser is based upon Direct Frequency Synthesis, DFS, whereby the 1GHz input reference signal is multiplied, filtered and mixed to generate a given number of isolated and filtered single tone CW signals from the 1GHz comb. A finely tuned signal is then generated using a multi-way switch to select between the 1GHz spaced CW tones and mixed with fine resolution signals generated using a custom DDS/VCO PLL network. In this way finely tuned signals can be generated between 7.5GHz and 23GHz.
-
Product
Digital Frequency Meter
CSF-400
-
Measuring frequency. Accuracy: +/- 0.05%. 4 Digital display: 9999 Input Max. 400Hz/600 V, 30KHz/12V. Aux. Power AC 115/230V +/-15%, 50/60Hz. Isolation Aux. Power 12Vdc, 24Vdc, 48Vdc, 110Vdc available in option. Easy-to-wire, screw type terminal. Outside dimensions is DIN standard (96mm x 48mm) High stability & low cost.
-
Product
Standard Lifetime Measurement System
Filter-Based Systems
-
*Excitation by bh ps Diode Lasers (BDS-SM or BDL-SMN Series)*Optional: fs Fiber Laser*Wavelength Selection by Filters*Detection by bh HPM-100 Hybrid Detectors*Excellent Dynamic Range*Ultra-High Time Resolution*IRF Width Down to 40 ps FWHM with HPM-100-06/07*Low Cost Detector Option: PMC-150 PMT Modules
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2J40
General Purpose Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
High Power Frequency Converter
BL+ Series
-
Behlman's BL-PLUS Series High Power AC Source/ Frequency Converter provide the performance of a linear with all the benefits of a switching amplifier. Instead of relying on large, noisy motor generators for AC power, today's testing facilities are switching to quiet, compact Behlman AC Power frequency converters.
-
Product
Rack Module with Standard Contactors without Anti-Harmonic filters
MOD Rack
-
Lifasa - International Capacitors, SA
The MOD-RACK control units include, in a compact form, all the components necessary for the operation of a step of a standard capacitor bank. MOD-RACK modules are divided into two basic blocks: power block and control block. The two blocks are mounted in a small frame to be installed in an electrical panel.
-
Product
High Frequency Insulation Tester
HFIT 7.0
-
The MEDTEQ high frequency insulation tester is a popular device for evaluating compliance with IEC 60601-2-2 and the characteristics of insulation at high frequency
-
Product
CPCI-S.0 Standard Compliant Peripheral Board Controlled by a PCIe Channel Derived from the Backplane Connector P1
MIC-3820
Backplane
MIC-3820 is a 2.5" on board SSD/HDD carrier board running at SATA Gen3 speed. A fast swap of the drive can be accomplished via a reserved thumb screw to help open a door on the front panel and eject the drive. The excellent mechanical design makes it easy to replace modules.
-
Product
Standard 2.00 (57.00) - 6.00 (170.00) Non Replaceable General Purpose Probe
F-S-W
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 66Recommended Travel (mm): 1.68Overall Length (mil): 780Overall Length (mm): 19.81Rec. Mounting Hole Size (mil): 86Rec. Mounting Hole Size (mm): 2.18Recommended Drill Size: #44
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1H-4-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Dytronic Primary Transfer Ultra Stable Standard
RD-22 Ultra
-
The RD-22 Dytronic Primary Transfer Ultra Stable Standard represents the state-of-the-art technology in a commercially available AC transfer reference. The Ultra Stable RD-22 is a variant of the RD-22 Primary Transfer Standard that has been optimized for 120/240 V @ 5A operation to provide optimum stability. In a stable test environment, repeatability for a 10-second test of ±0.6 µWh/VAh is attained at 120 V and 240 V at 5A inputs with a 95% confidence interval. A typical experimental 2 repeatability of less than ±0.25 µWh/VAh is achieved. In a stable test environment, a reproducibility of ±2 µWh/VAh over a five-day interval is attained at 120 V and 240 V at 5A inputs with 95% confidence interval.