product
Programmable DC Load Current Waveform Generator
9923
9923 application software can be used to edit arbitrary waveform, providing electronic load simulation different sink current conditions
-
product
PXI/PXIe Wide Current Range Multiplexer Module, Single 12-Channel, 2-Pole
40-514-105
The 40-514-105 (PXI) and 42-514-105 (PXIe) are low density multiplexers in single 12-channel, 2-pole configuration. They are capable of switching a wide range of current, from 10 μA to 2.5 A at 220 VDC/250 VAC. The current capability of the module permits the use of a single module type for both low and medium current test applications.
-
product
Bluetooth Recording Current Meter
RCM Blue
A self-recording dedicated current meter with Bluetooth for communications and data retrieval - now with the possibility to integrate a pressure sensor!The RCM Blue is a self-recording Current Meter which also measures water temperature in salt or fresh water, and a battery container with battery capacity up to 70Ah. .The Doppler Current Sensor is an upgraded version of the proven SeaGuard ZPulse sensor. The RCM Blue instrument configuration and data retrieval is done via Bluetooth which eliminates the need to open the pressure case for repeated deployments.RCM Blue has now been upgraded with the possibility to integrate a pressure sensor with a 0,01% accuracy. This simplifies your work significantly as you will know exactly where you are in the water column.
-
product
AC/DC Power Clamp Tester
IBL-307
International Biological Laboratories
This Digital Clamp On Power Meter Model 307 can be used to measure True Power, Apparent Power and Power Factor in single phase circuits. It measures AC/DC Current and incorporates a frequency counter. It is autoranging type Digtal Clamp On Power Meter and has 3-3/4 Digits 4000 Counts with 40 segment analog bargraph LCD Display.
-
product
Laboratory EM current meter / water level and wave height meter
ACM2-RS and ACM3-RS are 2-D and 3-D electro-magnetic current meters for laboratory experiments. The models provide digital output, a high-speed sampling rate and insusceptibility to electro-magnetic noise. ACH-600RS is a highly sensitive capacitance water level meters. With the new system, a maximum of four different sensors can be connected to the compact interface unit, enabling simultaneous recording on a personal computer. Additionally, the system can provide analog output as well as necessary. While conventional water level and wave height meters cannot be used near velocity sensors, our instrument can be as near as 5 cm without increasing noise, due to its special isolated circuit. The result is an innovative system that is capable of achieving highly accurate data.
-
product
NI-9265, 4-Channel C Series Current Output Module
783733-01
4-Channel C Series Current Output Module - The NI‑9265 is ideal for interfacing and controlling industrial current-driven actuators at high rates. The module has built-in open-loop detection, which generates an interrupt in software when an open loop is detected as well as zeroing outputs to ensure safety and avoid driving actuators at system power on. The NI‑9265 requires an external power supply and includes a channel‑to‑earth ground double isolation barrier for safety and noise immunity.
-
product
Closed Loop Hall Effect Current Sensors/Transducerswith Rectangle Windows
ChenYang Technologies GmbH & Co. KG
This Hall Effect current sensor is based on closed loop compensating principle and can be used formeasurement of DC and AC current, pulse currents etc. The output of the transducer reflects thereal wave of the current carrying conductor.
-
product
DC In AC Clamp Tester
M-800P
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Model 800P is the world’s first clamp meter which can detect smallDC current in AC circuit in addition to general AC/DC current measurement.*By using this clamp meter, DC offset surveillance can be madeeasily in the actual fields like as solar inverters, etc. and it is possibleto check if the DC component in AC circuit is less than 1% ofthe rated AC current or not, according to the regulation.
-
product
Clamp type AC Current Sensor/with DC Voltage Output
RCT-18
MULTI MEASURING INSTRUMENTS Co., Ltd.
Leakage current measurements with DCV output for recorder. AC 0.1mA~100mA.
-
product
PXI/PXIe Wide Current Range Multiplexer Module, Single 6-Channel, 4-Pole
40-514-102
The 40-514-102 (PXI) and 42-514-102 (PXIe) are low density multiplexers in single 6-channel, 4-pole configuration. They are capable of switching a wide range of current, from 10 μA to 2.5 A at 220 VDC/250 VAC. The current capability of the module permits the use of a single module type for both low and medium current test applications.
-
product
AC/DC Clamp Meter
3810 CL
Standard Electric Works Co., Ltd
● Full auto range for V.A and Ω functions.● Data hold function freezes the reading in dimly lit or hard to reach places.● Low battery indication.● Built-in buzzer for continuity test.● Safety design throughout with no exposed metal parts. Shielded banana plugs and recessed input terminals.● Ohm function ideal for checking continuity of relays transformers and motor coils.
-
product
Three Phase Secondary Current Injection Test Set
TEST-330B
Beijing GFUVE Electronics Co.,Ltd.
Three phase secondary current injection test set is testing relay set, protective device, instruments, output ac dc current and voltage source, embedded Window XP system.
-
product
Analog Clamp Tester (CE)
M-3000
MULTI MEASURING INSTRUMENTS Co., Ltd.
*High accuracy analog display with strong taut band meter.*Meter lock function.*AC current, AC/DC voltage and resistance measurements.*Conform to IEC safety requirements.
-
product
AC/DC TRMS Insulation Clamp Meter
CMi210
A unique insulation clamp meter for the installation, testing and maintenance of domestic and industrial installations. This high specification clamp meter can perform insulation tests to 6G Ohms with 5 test voltages from 50V to 1000V.
The clamp provides True RMS measurement of AC current to 1500A and AC voltage to 750V. It will also measure DC current to 2000A and DC voltage to 1000V. The CMi210 has all the same test functions you would expect to find on a high specification multimeter with the added benefit of temperature measurement.
-
product
12-Channel VME Current Loop/Process Control I/O Module
V220
The V220 is ideal for driving and sensing transducers in computer or PLC-based control systems. It can also be used to simulate complex industrial processes to control systems under development and certification.
-
product
Precision Multirange Current Transformer
P-2000
The Type P-2000-2 Knopp Precision Current Transformer is useful for high and low voltage work in the laboratory, shop and field for testing, measuring, and calibrating. The excellent accuracy and the One-to-One calibrating feature make it admirably suited as a standard for calibrating work.
-
product
AC/DC Clamp Meter
CM4374
• AC/DC Clamp • True RMS • 600/2000 A range • V, A, Hz, Ω, and other extensive measurement parameters • Inrush current • Max/Min/Avg/Peak • Wireless data download to a tablet or smartphone
-
product
Digital AC/DC Auto-Ranging Clamp Meter
PCMT20
Measures AC and DCMax. Resolution to Current Measurement: 0.1uALCD Display with BacklightData Hold, Zero Function, Auto Power OffLower Battery Indiactor0.9' (23mm) Jaw SizeDC Voltage: Range: 0-600 V; Accuracy: +/- 0.5%AC Voltage: Range: 0-600 V; Accuracy: +/- 1.5%AC Current: Range: 0-400 A; Accuracy: +/- 3.0%Resistance: Range: 0-40 M; Accuracy: +/- 3.0%Temperature: Range: 1000 C / 1832 F; Accuracy: +/- 3.0%Capacitance: Range: 100 uF; Accuracy: +/- 2.5%Frequency: Range: 150 kHz; Accuracy: +/- 1.2%Continuity: Buzzer Sounds at 100Diode: Test Current 0.3mA; Open Circuit Voltage 1.5VBatteries: 2 x AAA IncludedAccessories Included: Black Bag, Test Leads, Type K Temperature ProbeDimensions: 8.07' H x 2.36' W x 1.18' DWeight: 7.94 ozSold as : Unit
-
product
High Voltage Surge Current Monitors
HVSCM
Designed to be used with the Model HVST High Voltage Surge tester. The Surge Current Monitor allows simultaneously surge testing 20 units. The Surge Current Monitor monitors the current going through each unit under test at the time of the surge. If a unit under test breaks down or leaks, the Surge Current Monitor will identify the bad unit by lighting the corresponding LED. The most important features of the surge tester are its ability to test the entire winding insulation system. A high voltage surge generates turn to turn, coil to coil, and phase to phase voltage stress, as well as ground insulation stress. When used as a dielectric test, accurate voltage readings are essential. The HV Surge Tester monitors the voltage directly across the winding under test. In production testing we expect that most of the time the devices will pass. In the event that one should fail, the failed device would be removed and then all the parts would have ot undergo another surge test. Since most devices pass most of the time, simultaneous surge testing can be a real time saver.
-
product
Current Generator
SL / 650
Wuhan Huatian Electric Power Automation Co., Ltd.
It is suitable to supply primary current or other single-phase 50Hz power supply equipment when calibrating current transformer.
-
product
Standard Current Transformer
HL / 640
Wuhan Huatian Electric Power Automation Co., Ltd.
It is used as the calibration standard of current transformer in the error test of transformer.
-
product
Clamp Meter
Shenzhen Graigar Technology Co.,Ltd.
A clamp meter is an electrical tester that combines a basic digital multimeter with a current sensor. Clamps measure current. Probes measure voltage.
-
product
4 Phase MICRO~Flex AC Current Probe
DRM 504/4
The new DRM 504/4 is a 4 Phase MICRO~flex AC current Probe utilising the Rogowski principle, with 4 channel integrator housed in DIN Rail Mounted Enclosure. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas and with large conductors.
-
product
AC Current / Leakage Digital Clamp-on Tester
MCL-500DFN
MULTI MEASURING INSTRUMENTS Co., Ltd.
MCL-500DFN AC Current / Leakage Digital Clamp-on Tester
-
product
Current Measurements of PWM or Inverter, AC/DC 10~200A, φ24mm
CTF-200DC
MULTI MEASURING INSTRUMENTS Co., Ltd.
*AC/DC 10~200A*Current measurements for PWM or inverter
-
product
Current Transformer
ST-30CT
Standard Electric Works Co., Ltd
● 30/5A - 150/5A● 2-3V A● Class 1● Insulation 600V
-
product
Ultrafast Photodetector with Current Monitor, 700 - 870 nm, DC - 12 GHz, FC/PC
DXM12CF
The DXM12CF Ultrafast Detector is a DC - 12 GHz, fiber-coupled, GaAs-based photodetector designed for applications in the 700 nm - 870 nm wavelength range. The core element of the detector is the fiber-coupled, hermetically sealed, microwave detector module. For convenience and simplicity of use, the module is mounted inside a rugged housing that includes a rechargeable battery, current monitor circuitry, and a digital display of the DC photocurrent.
-
product
Current Sensing Resistors, Metal Plate Type -MS, MB
Panasonic Industrial Devices Sales Company of America
An AEC-Q200 Compliant SeriesPanasonic components specified as AEC-Q200 Compliant are consistently designed into automotive systems. However, today’s Design Engineers are specifying AEC-Q200 components to meet the high-quality standards of devices beyond automotive applications.
-
product
High Speed-Large Current DC Electronic Load (CC/CV/CR/CP)
PLZ-4WL Series
While the PLZ-4WL series succeeds to the superior operability of our conventional model of the PLZ-4W series, the PLZ-4WL series realizes the high speed rise and fall time (slew rate of 50A/µs.) in the range of low voltage with large current. The PLZ-4WL offers six operation modes, and equips with various features such as sequence operation, switching operation, soft-start function, and time and voltage measurement. The PLZ-4WL applies not only for the conventional load test of the CPU power supply, but also it can be applied to even faster current response test. In addition, the PLZ-4WL is a space-saving design (about 50% less volume of the conventional model) that can save the facility space of the testing site, and it can be applied for the single cell testing of the large scale rechargeable battery.