product
Oscilloscope, 350 MHz, 2 GS/s interleaved, 4 CH, 200 Mpts/Ch interleaved, Fully Loaded DSO with 16 Dig Ch MSO
T3DSO2354HD-MS
The T3DSO2000HD series of Bench Oscilloscopes feature 4-channel models with analog bandwidth options of 100 MHz, 200MHz and 350 MHz. The T3DSO2000HD Oscilloscopes use 12-bit high resolution ADCs and a low noise front end which provides an impressive noise performance to cover a wide range of measurement applications. Each model offers a maximum sample rate of 2 GSa/s (interleaved) and a maximum memory depth of 200 Mpts in interleave mode. The MS configured models also include a 16 channel logic probe as standard.
-
product
Oscilloscope, 200 MHz, 2 GS/s interleaved, 4 CH, 200 Mpts/Ch interleaved, Fully Loaded DSO with 16 Dig Ch MSO
T3DSO2204HD-MS
The T3DSO2000HD series of Bench Oscilloscopes feature 4-channel models with analog bandwidth options of 100 MHz, 200MHz and 350 MHz. The T3DSO2000HD Oscilloscopes use 12-bit high resolution ADCs and a low noise front end which provides an impressive noise performance to cover a wide range of measurement applications. Each model offers a maximum sample rate of 2 GSa/s (interleaved) and a maximum memory depth of 200 Mpts in interleave mode. The MS configured models also include a 16 channel logic probe as standard.
-
product
Beam and Singlepoint Load Cells
We have trimmed all the non-essential fat off these load cells, however you can be sure that nothing has been trimmed from the actual load cells, they are precision tested and certified to meet all the exacting requirements on the downloadable technical specifications shown below.
-
product
Programable Power Supply & Programable Electronic Load
EL-820P
*Digital button control and easy operation*High resolution(20mV, 10mA, 0.1W, 0.1Ω)*Overload prevention function*9 sets programmable memory*4 sets real time display*Voltage range: 1V~63V*Current range: 10mA~15A*Maximum power: 200W*Operation mode: CV, CC, CP and CR*Built in USB interface
-
product
DC Electronic Load
3310F Series
Each 3310F Series module has its own control and display panel, CC/CR/CV/CP/Dynamic modes, plug in 3300F with 150 sets Store/Recall memory which provides load set-up more efficiently,also can be controlled intranet via RS232、Ethernet、USB and GPIB interface.
-
product
S-Beam Static Load Cells
2519 Series
The 2519-xxxN Series load cells are specifically designed for use with 3300 single column testing systems. Automatic transducer recognition and electrical calibration makes them easy to use. The load cells incorporate overload protection and can withstand loads up to 150% of their force capacity without damage and 300% without mechanical failure. The load cells allow the user to zero out the tare weight of a grip or fixture that weighs up to 40% of the force capacity, while still maintaining the full specified accuracy.
-
product
Force Sensors, Load Cells, Shear Beam
INELTA Sensorsysteme GmbH & Co. KG
Exact force measurement and weight measurement
-
product
S Beam Load Cell
Futek Advanced Sensor Technology, Inc.
FUTEK S Beam Load Cells (Tension/Compression) offer a compact design for a variety of applications. Available in standard and metric, the S Beam Load Cell series provides accuracy, compact design features, overload protection (select models), and a wide capacity range to choose from. S Beam Load Cells are also commonly known as Z Beam Load Cells or S Type Load Cells.
-
product
Programmable Single Channel DC Electronic Load, 150V/30A/200W
T3EL150302P
Programmable Single Channel DC Electronic Load, 150V/30A/200W.
-
product
230V / 36 Amp Load
EL08-230M
For High Voltage UPS Battery Testing and Power Supply testing. This particular Load has been designed to operate with UPS Battery Systems and Telecom Rectifiers and Power Supplies with output Voltages in the range of 153V to 230V and is extremely cost effective.
-
product
Phantom Load Test Set
Is a testing accessory, wisely designed for field testing service. This equipment helps in providing artificial load that is unaltered by the change in power supply.
-
product
Signal/Micro Power/ Micro Coax, Module, Receiver, QuadraPaddle, iCon Series, 100/15 Position, loaded w/ twin female contacts & round posts
510160113
This module comes fully loaded with twin female contacts & round posts (p/n's 610138200 & 610138117).iCon modules mount from the rear of the iCon/i1 receiver and ITA and allow installation and removal of pre-wired cable blocks. Primary mating module 510161107. (May mate with other ITA modules, as well.)
-
product
High Speed Load Cell Test Interface
LCIC-4CH
Industrial Measurement Systems Ltd.
The latest stand-alone controller model: LCIC-4CH, was specially designed to fit portable wheel and axle scales for determining the weight of trucks or heavy vehicles either in static mode or in motion, with very high accuracy and very friendly to operate. The In-motion speeds up the weighing process and allows weighing a truck without the need to stop.In the last 16 years, our stand-alone High-Speed weighing-in-motion controller model: LCIC-WIM was sold all around the world and as for today, thousands are being in use when among our customers are some well known weighing manufacturers.Most of our customers around the world are scale manufacturers or integrators that were able to offer the market the most advanced WIM scale with very short time to market and minimum R&D expenses.
-
product
DC Electronic Loads
Keysight DC electronic loads provide you with the flexibility to test a wide range of applications from power-supply test to simulation of high-intensity discharge (HID) headlamps. The 16-bit voltage, current and power-measurement system provides both accuracy and convenience, and eliminates the need for a DMM, external shunts and wiring.
-
product
500 AMP Carbon Pile Load Tester
CP710
Tests batteries rated as high as 1000 CCA or 160 amp hour. Also tests alternators, regulators, and starters
-
product
Water Cooled Active Resistance DC Electronic Load
WRx Series
Utilizing Magna-Power’s new patent pending Active Resistance Technology in combination with the company’s internally manufactured microchannel water-cooled heatsinks, the WRx Series addresses high power DC applications where exhaust heat control is essential. The WRx Series greatly increases power density compared air-cooled alternatives. An integrated solenoid controls the flow of water to avoid condensation. Full power can be achieved using conventional water, with water inlet temperatures up to 25 °C.
-
product
Heavy Duty Shear Beam Load Cells
SBL SERIES
The SBL Series heavy duty shear beam load cells are ideal for process weighing and for use in low profile industrial scales. These economical load cells are easy to install and durable in the field. Environmental protection is afforded through water resistant potting, a compression sealed and strain relieved cable entry, and corrosion resistant nickel plated steel.
-
product
600~1500W DC Electronic Loads
JT632 series
Nanjing Jartul Electronic Co., Ltd
JT632 series electronic load is functioned with 500KHz high-speed synchronous sampling, DSP technology, powerful dynamic test and multi-aspect intelligence analysis. All these are fully integrated into auotmatic test function, which makes JT632 series load very suitable for testing power supply when produced in large quantity. Besides, JT632 series load also possesses the features of current rising slew rate programmable, high-speed dynamic loading and programmable list function, which makes JT632 series load satisfing most of R&D requirements.
-
product
Partial Load Failure
PLF Device
The control device series “PLF” has been designed to monitor the partial and/ or total failure of the alternating current absorbed by loads driven by static switches and / or electromechanical relays.
-
product
Liquid-Cooled Load Banks
Guangdong EMAX Electrical Co., Ltd.
EMAX's liquid-cooled load banks are the best choice for industries and applications with their high efficiency, compact size, quiet operation and precise load testing.
-
product
3 Way GPS / GNSS Signal Splitter Passive, 1-2 GHz, SMA, DC Block+200Ω Load 3 Ports
GPS312
INSTOCK Wireless Components, Inc
GPS L1 - L5, GLONASS, Galileo splitterLow Insertion Loss (0.3 dB avg)High Port to Port Isolation (30 dB avg)Excellent VSWR (1.10 : 1 avg)15 VDC & 75 mA max on DC block portsTri Alloy SMA Female (Jack) 50 Ohm
-
product
Four Channel Load Cell Tester
LCIC-4HS
Industrial Measurement Systems Ltd.
Four Channel Load Cell Interface Card Model LCIC-4HS The LCIC-4HS is a four channel load-cell interface board for the IBM PC/AT and compatible computers (ISA Bus). This board was especially designed to fit very fast and real-time weighing applications such as multi-head fillers. It supports up to four channels with one load-cell on each. All the necessary filters and the batching control functions are built on the board and are easily accessible by the user. Direct communication with the PC bus and high-frequency sampling enables the LCIC-4HS to handle all real-time applications and to achieve very high accuracy. The LCIC-4HS is memory-mapped. Up to 32 boards (128 channels) may be installed in a single PC. It comes with a detailed user manual and software utilities for easy installation and calibration as well as full examples for the programmer (including Win 95/98 drivers).
-
product
Battery Loading Unit
BLUe
BLUe series Battery Loading Units; portable instruments for controlled & monitored discharge of batteries. It is designed for integrated site discharge test, design & QC test and also for monitoring discharge process of battery bank with connected load. Single autonomous unit having inbuilt display, keypad and wireless communication with PC makes it very easy to use. It comes in different configurations ranging from 12V to 380V discharge voltages and 50A to 300A discharge currents. Various options are available to control & monitor the discharge process. With the help of optional Cell Monitoring Unit - CELLMon, voltage of each individual cell can be monitored & data sent to main BLUe unit and then from main unit to PC via wireless communication. Each BLUe unit is supplied with PC downloading & analysis software for real time monitoring of discharge process.
-
product
3U VPX RL Thermal Load Simulation Module
The 3U power test module is an ideal solution for evaluating heat dissipation in a rugged conduction cooled VPX cage or chassis. This card is a thermal load in the chassis to evaluate the heat dissipation. The chassis can be monitored with temp sensing probes and or FLIR imaging. Different wattages are selected by setting dip switches. The +5 and 3.3V loads are on the top of the module. The +12V and -12V loads are on the bottom side of the module.
-
product
Bolt Extensometers for Proof Load Testing
Model 3565
Jinan Testing Equipment IE Corporation
The Model 3565 uses hard conical points to contact the bolt at the center of the head and at the bottom. It is fully adjustable for different length bolts ranging from 25 mm (1 inch) in length to 150 mm (6 inches) standard. Extension beams are available for longer bolts. The standard maximum measuring range is 1.25 mm (0.05 inches). Generally, on longer bolts this extensometer will be self-supported without requiring any centering marks or punch marks on the bolt. For shorter bolts these marks may be required. If the conical pins are sharp, marks are often not needed even on the shortest bolts.The extensometer has a zero adjustment screw to adjust the length between the contact pins. This is used to set the output voltage to zero, which corresponds to the correct starting position for the test. It also includes a breakaway lower arm. In the event a bolt should fail, the breakaway arm snaps free, helping to prevent damage to the extensometer. This is easily re-installed. In the event that bolt failures are likely during a test, it is recommended the user attach a cord around the upper part of the beam and tie the other end to the test frame to prevent the extensometer from falling. The conical point contacts included with the extensometer are made from tungsten carbide.The Model 3565 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.
-
product
Road Load Data / Durability
Vehicle Durability Testing and Road Load Data AcquisitionA road load data acquisition system from Dewesoft is a perfect vehicle durability testing solution for real-drive tests or tests on the road simulator test benches. Our advanced DAQ technologies will shorten time to test dramatically and make sure you get the correct measurements right the first time.
-
product
Compression Load Cell
EST-20
Technopark Automation & Control
The EST-20 is an industry standard Compression Load Cell that can also be used in tension. This load cell can be supplied with load button and cup as well as ball and cup mounting options and is typically used on high capacity silos, hopper scales, batching systems, platform scales, force measurement and tension measurement applications. It is available in capacities from 1 ton to 50 ton.
-
product
Loaded Spectrophotometer
DSCD-900
DSCD-900 is a highly performance spectrophotometer with test caliber upward. The instrument adopts the geometric conditions of D/8 lighting and observation of CIE recommendations, integration of the full band LED composite light source, double beam optical system, ETC every-time calibration technology, spectral reflectance standard deviation within 0.08, maximum of colorimetric values ΔE*ab is 0.03, to provide all the necessary color formula. It could be widely used for coating, printing, textile, meet plastic, food, medicine, automobile field to meet customers’ measurement requirement.
-
product
VME Load Card
WIENER VME load boards are designed to test VME crate power supplies and fan trays by drawing power from the VME backplane and dissipating it as heat. A series of switches on the module front panel allows for easy adjustment of the current draw for each voltage channel.