Product
Standard 2.00 (57.00) - 6.00 (170.00) Non Replaceable General Purpose Probe
F-S-C
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 66Recommended Travel (mm): 1.68Overall Length (mil): 780Overall Length (mm): 19.81Rec. Mounting Hole Size (mil): 86Rec. Mounting Hole Size (mm): 2.18Recommended Drill Size: #44
-
Product
AC Measurement Standard
5790B
-
The 5790B is a multi-purpose ac measurement and transfer standard designed for the most demanding calibration applications. It combines the accuracy you expect from a thermal transfer standard with the ease of use of a digital multimeter. Absolute ac voltage measurement uncertainties are as low as ± 24 ppm (one year, 23 °C ± 5 °C).
-
Product
Standard 1.02 (29.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-62J-4
ICT/FCT Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 0.49 (13.89) - 2.50 (70.87) Battery Probe
CP-4C
Battery Probe
Current Rating (Amps): 10Average Probe Resistance (mOhm): 25Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 60Full Travel (mm): 1.52Recommended Travel (mil): 40Recommended Travel (mm): 1.01Overall Length (mil): 311Overall Length (mm): 7.90Overall Length Remark: Overall length does not include tail.
-
Product
3207a GPS/GNS Frequency and Time Reference
GlobalTyme2
-
Precise Time and Frequency, Inc.
The ptf 3207A GlobalTyme2 GNS Receiver introduces a new level of advanced capability from a second generation, based on the highly successful ptf 3203A and ptf 3204A GlobalTyme receivers.The unit is both a frequency standard and a time standard and has been used as a precision frequency reference with low phase noise, in satellite communications applications around the world.
-
Product
130/180 MS/s Dual Channel PXI Express Digitizer for Frequencies up to 175 MHz
PXIe-1803
Digitizer
This 130/180 MS/s Dual Channel PXI Express digitizer provides the best speed and performance available for input frequencies up to 175 MHz.With exceptional signal integrity, high density and modularity, and channel synchronization options, this new digitizer provides massive functionality in a compact form factor.Key features include:Dual 14/16-bit digitizer configurable as separate or fully synchronized channelsWaveform bandwidths of 65-175 MHz (typical)64M words of waveform memory per channelExternal clock input for synchronization up to 180 MHz250 μV Measurement AccuracyNoise Floor and RelativeAccuracy as Precise as 0.006%
-
Product
Standard Precision GNSS Module
AIW-213
-
Half size mini-PCIe form factorStandard Precision GNSS L1 band92 Channels u-blox NEO-M9 engine (GPS, GLONASS, BeiDou, Galileo, QZSS and SBAS)USB 2.0 communication interfaceSupport Dead Reckoning (DR), Including IMU and Oscillator2 second TTFF for Hot Starts, Open sky code start 24 second.Accuracy 1.5M CEPOperating temperature: -40°C ~ +85°C / -40°F ~ 185°F
-
Product
Standard 0.95 (26.90) - 4.50 (128.00) Battery Probe
CP-2SB-12
Battery Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 128Full Travel (mm): 3.25Recommended Travel (mil): 118.1Recommended Travel (mm): 3.00Overall Length (mil): 472Overall Length (mm): 12.00Overall Length Remark: Overall length does not include tail.Recommended Drill Size: #53 or 1.51 mmRec. Mounting Hole Size (mil): 61Rec. Mounting Hole Size (mm): 1.55
-
Product
IEC Standard Burden Sets (Current)
IEC Burden Sets
-
Testing and calibrating current transformers often requires standard burdens of reliable accuracy and stability, and burdens that are immune to stray fields and harmonics. These burden sets have been carefully designed to meet these requirements. They also provide the standard burdens required for the testing of current transformers for metering service, and for the testing (within the current rating provided by the sets) of current transformers for relaying applications, all as called for by IEC (International Electrotechnical Commission) Publication 185: 1987.
-
Product
Rack Module with Standard Contactors with Anti-Harmonic Filters
MODF Rack
-
Lifasa - International Capacitors, SA
The MODF-RACK control units include, in a compact form, all the components necessary for the operation of a step of a capacitor bank with filters. MODF-RACK modules are divided into two basic blocks: power block and control block. The two blocks are mounted in a small frame to be installed in an electrical panel.
-
Product
Monolithic Balanced Mixers With Intermediate Frequency Amplifier
-
Insight Product Company offers Monolithic Balanced Mixers with and Intermediate Frequency Amplifier in frequency range of 26 to 178 GHz.
-
Product
Dual Frequency 900 kHz & 2250 kHz 2D Imaging Sonar
BlueView M900-2250-S 130/45-Mk2
-
The dual frequency M900/2250-S 130/45-Mk2 is a new configuration of the leading BlueView M900/2250 optimized for superb image quality in challenging shallow water environments. The 900 kHz offers high-resolution long range navigation, object detection, and obstacle avoidance, while the 2250 kHz provides ultra-high resolution at close range. ROV navigation, diver hand held, hull inspections, structure inspections, diver monitoring, and search and recovery are a few applications that benefit from the dual-frequency’s imaging capabilities. All M Series sonar operate while in motion or from a stationary position delivering real-time imagery and data.
-
Product
Hydrogen Frequency & Time Standard
CH1-1035
-
Hydrogen frequency and time standard Ch1-1035 is designed for precision storage and reproduction of the size of frequency and time units as part of measures and reference complexes.
-
Product
Single Frequency CW 532 NM Laser up to 18W
EQUINOX
-
Equinox is a single frequency, 532 nm continuous wave laser designed for a range of scientific applications including pumping any Ti:Sapphire laser systems. It is engineered to meet the needs of experimentalists requiring high-performance systems with an emphasis on reliability, stability and ease of use. The laser incorporates pump diodes within the central unit and is fully automated with hands-free operation and control via ethernet, webpage and TCP/IP remote interface. This completely sealed system is inherently stable with low noise levels <0.05 % RMS and ultra-stable output powers with ±0.5 % stability. Equinox has options of high output power up to 18 W. Other major applications include mixing source, pump source for dye lasers and frequency doublers, optical tweezers, and biomedical imaging.
-
Product
Frequency Converter
FC5-29M
-
Frequency converter FC5-29M is a measurement instrument which is designed for spectrum conversion of 75 - 170 GHz to 1 MHz ÷ 2,6 GHz range and automatic frequency measurement of sinusoidal signals. When combined with the 1 MHz - 3,0 GHz spectrum analyzer, FC5-29M can be used for examination of the continuous and periodically repeating pulse signals.The instrument is meant to be used for measurement of various signal sources, radio-transmitting instruments, synthesizers, frequency converters, measurement generators and also for adjustment and verification of various radio-transmitting or communication instruments in laboratory and workshop conditions.
-
Product
Pyranometer First Class standard (ISO 9060 / WMO)
CMP 6
-
The CMP 6 pyranometer is intended for routine global solar radiation measurement research on a plane/level surface.Fully compliant with ISO-9060 specification for a First Class pyranometer, the CMP 6 features a sixty-four thermocouple junction (series connected) sensing element. The sensing element is coated with a highly stable carbon based non organic coating, which delivers excellent spectral absorption and long term stability characteristics
-
Product
8-Channel, 100 MHz Counter/Timer/Frequency Meter Function Card
ProDAQ 3808
-
The ProDAQ 3808 function card, an enhanced version of the ProDAQ 3806 counter/timer function card, is designed to operate in one of three modes: pulse counter, frequency meter, or time interval counter. In the pulse counter and frequency measurement modes, users can process incoming signals of up to 25 MHz on each of the six channels. A time interval counter range is divided into six sub-ranges, covering times from 40 ns to 20000 s with a maximum resolution of 10 ns. For pulse-width measurements, the same ranges apply.
-
Product
Standard 1.00 (28.00) - 2.75 (78.00) Non Replaceable General Purpose Probe
E-S-R
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 65Full Travel (mm): 1.65Recommended Travel (mil): 43Recommended Travel (mm): 1.09Overall Length (mil): 495Overall Length (mm): 12.57Rec. Mounting Hole Size (mil): 67Rec. Mounting Hole Size (mm): 1.70Recommended Drill Size: #51Overall Length Remark: Overall length for E-S-V and E-S-W is .540 (13.72)
-
Product
Low frequency Amplifiers
-
Low-frequency amplifiers Current sources Systems with multiple amplifiers Customized systems
-
Product
Custom Optical Components and Standards
-
With the amount of applications that optical components have, no one could hope to have the perfect component for every possible scenario. For this reason, APPLIED IMAGE makes easy the process of designing, building, and delivering custom components to our customers. Our engineering process is designed to produce the best parts in the industry and more importantly, the best component for your specific needs. The APPLIED IMAGE experience will cover the project with expert engineers from start to finish. Use the form below to start the conversation for checkerboard and dot arrays, stage and image analysis micrometers, reticles and machine vision components.
-
Product
Rubidium Standard with Optional DDS Signal Generator
1450B
-
The 1450B outputs can be configured as sine waves or square waves and can provide frequencies of 10MHz, 1MHz, 100kHz, 1pps or optional signal generator outputs. The signal generator outputs use direct digital synthesizer (DDS) technology and are confirurable from 100Hz to 171MHz. The 1450B also includes a 1pps input that can be used to discipline and automatically calibrate the 1450B. The 1pps input signal is typically obtained from an external device like a GPS frequency receiver/antenna. The Novatech GPS1 Smart Antenna with 1pps output is available as an accessory to provide a complete turnkey solution.
-
Product
Standard 1.50 (43.00) - 4.00 (114.00) Bead Probe
BTP-25HL-4
Bead Target Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard VXI Module Shield Kits With Address Switch Opening
-
* Single-slot kit fits all VXI-1 Revision 1.0 to Revision 3.0 chassis.* Clamshell design fits C-size modules with 96-pin connectors.* Side shields include connector shrouds for maximum shielding.* RFI limiting, air vent slots along top and bottom edges for good air circulation thru the module.* Extruded front panel is bend resistant.* Address switch opening on component side shield.* Complimentary layout support includes PCB design template and CAD layout files.
-
Product
Online Audio Frequency Signal Generator
WavTones
-
We are proud to offer not only the best audio frequency signal generator on the net, but also a high-end sound generator, which compares favorably to the more expensive software and hardware tone generators!
-
Product
Standard 1.71 (48.00) - 3.00 (85.00) General Purpose Probe
HPA-74T65
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
Product
UV & Visible Frequency Mixing Module
SolsTiS EMM
-
The SolsTiS External Mixing Module (SolsTiS EMM) provides fully automated tuning in the visible (480-670 nm) and IR (1.1-4.5 µm) with further extensions options into the UV (300-350 nm). It delivers high stability sum and difference frequency mixing of SolsTiS wavelengths with other single frequency sources, primarily via high efficiency single pass mixing in PPLN. This all-solid state solution for wavelength coverage supersedes dye lasers, removing the hazards and instabilities associated with this toxic gain material. SolsTiS EMM delivers unparalleled performance and reliability, enabling you to automatically tune and scan over a broad wavelength range.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1T-4-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
ACCUplace Macro Calibration Standard
AP-M Series
-
With both X & Y axis metric scales, these dual axis targets are ideal for calibrating optical magnification in microscopes, linear distance, stage motion and squareness. In addition, with the larger area calibration scale, the calibration of low power optical systems over the longer distances can be easily carried out. The AP-M is offered on two standard materials; Glass (CG) and Opal (OP).