Product
ReCalibration and Post Calibration Software
SI58
-
The SI58 software allows the user to set zero and span as well as do full temperature compensation and linearity corrections for your Validyne USB pressure transducer. The SI58 provides everything needed to change the range of your transducer and calibrate it through the new full scale pressure. Corrections to non-linearity and temperature error are also possible. The SI58 software provides prompts to the operator for temperature and pressure points to achieve an accurate calibration.
-
Product
Photometric Ozone Calibrator
Model T703
-
Teledyne Advanced Pollution Instrumentation
The Model T703 is a microprocessor controlled ozone calibrator for precision gas analyzers. The Model T703 can deliver concentrations from 50 ppb to 5 ppm at flows from 1 LPM to 5 LPM.The Model T703 has two major components; the ozone generating device and the photometer. The ozone generator produces ozone by passing zero air over a UV lamp. Flow rate and lamp intensity are adjusted to deliver a specified ozone concentration by volume. The temperate and pressure compensated photometer, identical to that of the Model T400 ozone analyzer, provides feedback control of the UV lamp intensity, assuring stable ozone output. A nearly unlimited number of calibration sequences may be programmed into the non-volatile memory of the T703, covering time periods up to a year.
-
Product
Calibration Light Source
CAL2
-
Image Engineering GmbH & Co. KG
The CAL2, based on our 22 channel spectrally tunable iQ-LED source, can be adapted for use in many different areas.
-
Product
Power Calibrators And Power Quality Calibrators
-
Calmet Smart Calibration Devices
A power calibrator and a power quality calibrator are both specialized instruments used to verify and adjust the accuracy of other instruments, but they focus on different aspects of electrical power.
-
Product
4-in-1 OSLT Calibration Kit, DC to 18 GHz, Type-N (f) 50 Ohm
CK519A
-
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
Product
Light Meter Calibration Services
-
International Light Technologies
International Light has been offering light meter calibration services since we created the first USA-made light measurement system in 1965. Our full service calibration lab offers ISO 17025 Accredited (UKAS recognized) calibrations and certifications that are also N.I.S.T. Traceable.
-
Product
Portable Data Recorder For Acoustics & Vibration
DR-7100
-
The DR-7100 is a portable data recorder for acoustic and vibration with high accuracy.
-
Product
IDevice Calibrated Measurement Microphone
IMM-6
-
The Dayton Audio IMM-6 is a professional-quality measurement and recording microphone that is designed to work with the entire suite of Apple “iDevices” – iPad, iPhone, and iPod. The rugged construction and compact size make it the perfect companion for audio professionals who must work on-location performing acoustic analysis, monitoring audio levels, or recording. Each IMM-6 is individually hand-calibrated using a laboratory-standard measurement microphone, for consistent, repeatable measurements that match the level of precision previously offered only by expensive stand-alone microphones.
-
Product
Calibration Test Pumps
-
High-precision calibration & pressure testing is the key to success in the oil & gas, petrochemical, maritime, pharmaceutical and aerospace industries and the right calibration tools make all the difference. Ralston Instruments offers a wide array of intelligently designed, high-quality calibration test pumps that simplify complex calibration processes while providing fast, accurate results. All Ralston pressure test pumps are lightweight, extremely durable, and easy to disassemble and repair with standard hand tools. And for quick connectivity with the most effective results, they all come with Ralston Quick-test™ adapters for safe, stable, leak-free connections without the need for a wrench or thread tape.
-
Product
Mercury Argon Calibration Source
HG-1
-
The compact, low-cost HG-1 Mercury Argon Calibration Source is a spectral wavelength calibration source for UV-VIS-Shortwave NIR spectrophotometric systems.
-
Product
OTDR Training & Calibration Solution
-
In addition to network simulation applications, the Fiber Lab 800HE from M2 Optics is a professional optical fiber platform that enables technicians to practice using an OTDR to find splices, faults, or bad connections in a length of optical fiber. In addition to training, it can also be used by equipment servicing teams to calibrate OTDRs with fiber that includes pre-determined events at known points.
-
Product
Blackbody Calibrators
-
Omega offers a diverse portfolio of blackbody calibrators used to calibrate infrared pyrometers. Blackbody calibrators use a high emissivity target plate or target cavity to minimize error.
-
Product
Noise Control And Acoustical Consulting Services
-
Our acoustical consultants use the latest and most advanced noise prediction and modeling software, precision sound measurement equipment and detailed acoustical analysis that enable us to help our clients achieve their project's noise requirements and goals. Contact us before your noise challenges become noise pollution problems.
-
Product
Palm Size Digital Multimeter, Calibrated, 1999 Count, Mean Value, Manual Range, 3.5 Digit
72-7770 CAL DU
-
The 72-7770 CAL DU from Tenma is a palm sized digital multimeter with 3 3/4 digit LCD. It is 3 1/2digits with steady operations, fashionable design and highly reliable hand held measuring instrument. The meter measures AC/DC voltage, AC/DC current, resistance, temperature, diode and continuity. It is an ideal tool for maintenance. The multimeter features square wave output, data hold, low battery indicator and display backlight, This meter complies with the standards CE, IEC61010, in pollution degree 2, overvoltage category (CAT I 600V, CAT II 300V) and double insulation.
-
Product
RF Calibration Accessories
-
Employing good connector practice when using an RF calibrator not only avoids measurement errors and minimizes connector repeatability uncertainties but also reduces risk of damage to connectors and equipment. The 96000CONN and 9600CONN connector kits include a range of adapters and torque wrenches intended for use with the 96000 Series RF Reference Sources (9600CONN for the 96040A and 96000CONN for the 96270).The 9600CONN connector kit includes one each of 50 Ω and 75 N-Type male-female adapter for use with the 96000 Series levelling head as a “connector saver” or “sacrificial connector” to avoid risk of damage when making connections to UUT/DUT instruments.
-
Product
Test gas - for calibration
-
Test gases for gas measuring and gas warning devices.Enables the functional control and calibration of measurement technology.
-
Product
Multi Function Calibrators
-
This range of multi function calibrators are designed for accurately simulating various sensor values such as temperature, voltage and current for calibration purposes.
-
Product
MCB Thermal Trip Calibration Test Bench (IEC 60898 Cl 9.10.1.2, Annex I.1, IS)
-
The test system is designed and customized to carry out 2.55*Intest as per Table 7 (test c) of IEC 60898 (also mentioned for routine testing of MCBs. The test is done at dc current to exactly analyze and correct the bimetallic properties of the MCB as far as thermal tripping is concerned. The unit comes with a pneumatically operated test fixture with in-built dc stepper motor that is controlled by a micro controller / PC to calibrate the breaker into a narrow tripping band programmed by the user.
-
Product
NIST Calibration for D420-A
D420-A-CCNIST
-
- Choice of 4 GHz or 6 GHz bandwidth models- Up to 5 Vpk-pk dynamic range with low noise- ±3 V offset range- Low loading and high impedance for minimal signal disturbance- Ideal for DDR2, DDR3, LPDDR2- Deluxe soft carrying case- Innovative QuickLink architecture- Wide variety of tips and leads-- Solder-In Lead-- Optional Positioner (Browser) Tip-- Quick Connect Lead-- Square Pin Lead-- HiTemp Solder-In Lead
-
Product
Bond Force Measurement And Calibration Systems
BFS-20
-
Based on its design and easy handling it can be used also on other brands to measure the bond force.
-
Product
Intelligent Digital Multimeter, Calibrated, 3999 Count, Mean Value, Auto, Manual Range, 3.75 Digit
72-7755 CAL D
-
The 72-7755 CAL D from Tenma is an intelligent digital multimeter. It has auto range or manual range options and dual display with maximum reading 3,999 displayed in 40 analogue bars in scale making the measured value to be seen clearly and indicating the trend of changing quickly. In addition to conventional measuring functions, there is a new breakthrough in frequency test with maximum range of 400MHz. RS232C standard serial port is equipped with meter for easy connection with computer to realize macro recording and monitoring and capture of transient dynamic data, displaying change of waveform during measurement, providing data and evidence to engineering technicians for scientific research. This is also a highly applied digital multimeter of high performance with full input protection and display backlight. The orange and grey colour meter features 73mm × 50mm size LCD, CAT III 1000V and CAT IV 600V safety ratings.
-
Product
Humidity calibration with humidity calibrator
HUMOR 20
-
The role of humidity calibrations that are accurate, reproducible, and documentable is becoming more and more important. The humidity calibrator HUMOR 20 developed by E+E is the ideal reference instrument for these requirements and is traceable to international standards. The HUMOR 20 can be used in the humidity range of 10-95% RH both for monitoring cylindrical sensors and also for monitoring instruments with cubic dimensions.
-
Product
Calibration & Testing Unit for AC & DC Meters
-
Supreme Instrument Laboratories
Calibrator for calibration and testing of A.C. Milliammeters, Ammeters, Voltmeters, and D.C. Microammeters, Milliammeters, Ammeters, Millivoltmeters and Voltmeters having following technical specification
-
Product
Calibration Hand Pumps
-
Nagman Instruments & Electronics Pvt. Ltd
Calibration hand pumps are the most cost-effective way to calibrate pressure devices. At Nagman, you can find Calibration hand pumps that are the best in the industry. Calibration hand pumps are used to generate pressure. Which can be hydraulic, pneumatic, or vacuum. This kind of pressure generation is done during testing and calibration applications. We also offer calibration pumps that can help in high pressure to low pressure calibrations. Visit Nagman website and browse through the range of calibration hand pumps to find the right device for your calibration needs.
-
Product
Industrial Pressure Calibrator
2271A
-
The Fluke Calibration 2271A Industrial Pressure Calibrator provides a complete, automated solution for calibrating a wide variety of pressure gauges and sensors. Thanks to its modular design, it can be configured to meet different needs and budgets, and expanded to cover a broad workload. The 2271A is ideal for calibration laboratories starting out in pressure calibration because it offers wide pressure measurement capabilities in a single instrument. Everything you need for calibrating pressure is included; just connect supply pressure. And your investment will stand the test of time: as your workload grows and changes, the 2271A can grow and change too. Just add measurement modules.
-
Product
Calibration Software
-
Calibration software is available to automate all or part of many calibration processes, manage calibration and asset data, and perform other useful tasks as well. Fluke Calibration offers a variety of market leading software applications in each of its product disciplines.
-
Product
Calibration & Repair Services for Instruments in Process Control
-
Meeting customer needs is our number one priority. Hastings Instruments offers free technical support as well as personalized one-on-one customer service through a diverse organization of field Customer Service Representatives and Distributors. We have more than 50 field Customer Service Representatives that are situated to provide local support throughout the world.Additionally, reaching our Customer Service Department is only a toll-free number away (USA) and is available for your convenience. Faxing or E-mailing your question first will assure that it is reviewed before you speak to a Customer Service Representative. Also, following the steps listed in our trouble shooting guides (included in each product instruction manual) may help direct you to the appropriate department before you pick up the phone to call.
-
Product
Calibrator, Calibrated, Current, 185 mm, 78 mm, 38 mm, ± (0.25% FS +1 digit), ± (0.5%FS + 1 digit)
72-6694 CAL
-
The 72-6694 CAL from Tenma is a current calibrator. It provides quality and accuracy of handheld calibrator of precision current source. It features large LCD display (maximum display counts 1999, 13mm (0.5") digit size). The current calibrator has 006P DC 9V, MN1604/PP3 battery or equivalent alkaline type or heavy duty type power supply. The dimension is 185mm × 78mm × 38mm (7.3" × 3" × 1.5") and weight is 265g/0.58lb (including battery). It has adjustable 0 to 24mA current source, 2 ranges (0 to 19.99mA (0.01mA display resolution, ±(0.25% FS + 1d) accuracy), 0 to 24mA (0.1mA display resolution, ±(0.5% FS + 1d) accuracy).
-
Product
Calibration
-
Testwave LLC calibrates electronic, physical, & dimensional test equipment. Our Sparks facility includes a state-of-the-art temperature controlled calibration laboratory, which holds the temperature to within +/- 0.5°C. We send recall notices before your equipment calibration expires, and if we don't hear from you, we will call, to make sure you stay in compliance for your calibration requirements.